Description
Cardioline Cubeholter ECG Holter system
Cubeholter is the ideal solution for the comprehensive management of the Holter test in your centre. Thanks to an intuitive user interface and the high performance of its analysis algorithms, it represents an effective, flexible and modular working tool, designed for professional environments that demand speed, reliability and an optimised workflow from start to finish.
The system works with 3- and 12-channel recorders, with sampling rates from 250 to 1000 samples per second and recording durations from 24 hours up to 7 days. Patient data can be entered into the recorder manually or from a worklist, and recordings can be downloaded quickly, both locally and remotely.
The award-winning algorithms automatically detect heartbeats and reject artefacts, classifying the main ventricular and supraventricular arrhythmias, atrial fibrillation and paced beats, and presenting the results in different formats. HRV, QTc and ST analyses are calculated automatically and displayed graphically or in tabular form, and the software generates an exportable final report. The raw data from the complete test can be stored in the Cardioline Holter Webapp web application and analysed from any location.
Technical specifications
| Characteristic | Specification |
|---|---|
| Recording channels | From 3 to 12 channels (1 to 12 leads) |
| Sampling frequency | 250, 500 or 1000 samples per second |
| Recording duration | From 24 hours up to 7 days (24 h, 48 h or 1 week) |
| Automatic analysis | RR, families, events, ST, QT (Bazett, Fredericia, Hodges) and HRV |
| Beat classification | Normal, ventricular, paced and artefact |
| Detected arrhythmias | Atrial fibrillation, bradycardia, tachycardia, supraventricular couplets and runs, idioventricular rhythm, supraventricular tachycardia, ventricular couplets, ventricular tachycardia, bigeminy, trigeminy, pause and junctional rhythms |
| Paced beats | Capture failure, undersensing and oversensing |
| Special algorithms | Noise and artefact rejection, atrial fibrillation |
| Configurable report | Precompiled summary, RR/HR trends, events, ST, QT, HRV; ECG tables and strips (max./min. RR, events, families) |
| Connectivity | HIS worklists in DICOM, HL7 and GDT; local upload or from remote stations via web-uploader |
| Report export | PDF or PDF plus complete recording with the Holter Webapp application |
Minimum workstation requirements
| Component | Requirement |
|---|---|
| Operating system | Windows 7 or higher, 32 or 64-bit |
| Processor | Intel Core i5 or higher |
| RAM | 8 GB or more |
| Disk space | At least 2 GB for the program plus space for the archive (local database, recommended limit of 1,000 tests) |
| Display | 6:10 format at 1600×1050, 22″ or more (100% resized) or 16:9 format at 1920×1080, 15.4″ or more |
| USB | At least 1 USB port |
| Printer | Black and white or colour laser |
| Safety standard | IEC 60950-1 |
Package contents
- Software for Holter analysis (Cubeholter software CD-ROM)
- User manual
- USB protection key
- USB backup software key
- USB connection cable
- Web charger
- 24-month warranty
Equivalences and cross-references
The Cubeholter system belongs to the Cardioline family of Holter analysis software. It is compatible with recorders of the same brand, such as the Walk400h series models and the Clickholter recorder, with which it shares the workflow of preparation, download, analysis and archiving of ECG tests through the Cubeholter software. Manufacturer reference: ABM-CUBEHOLTER (Source catalogue: AB Medica Group). No other direct equivalences with third-party manufacturers have been verified from reliable sources.
Selection tips and variants of interest
As it is a modular system, to configure a complete Holter station, in addition to the Cubeholter software, the appropriate recorder must be selected according to the type of test: 3-channel recorders for basic monitoring studies or 12-channel recorders for a more comprehensive assessment, with duration options of 24/48 hours or up to 7 days. Verify the minimum requirements of the working computer (Windows 7 or higher, Intel Core i5 or higher processor and 8 GB RAM) and confirm the compatible recorders and accessories, such as patient cables and USB keys, with your sales advisor. Sale on quotation: request your personalised offer.