1. Commercial Introduction
This ECG lead wire with 10 button-type electrodes (reference 54303) is the ideal replacement to keep your Holter ECG recorder model 54300 operational. Designed and manufactured by one of the European leaders in monitoring and diagnostic equipment, it guarantees a reliable connection between the patient and the recorder during ECG acquisition. It is the ideal replacement solution for cardiology consultations, diagnostic centres, primary care and sports medicine services that need to ensure the continuity of care of their equipment without compromising signal quality.
2. Technical explanation of the equipment and procedure
The lead wire is the component that transmits the electrocardiographic signal captured by the patient’s electrodes to the Holter recorder or electrocardiograph. This model features 10 electrodes with button-type connection, the most common fixation system in resting and monitoring ECG cables: the button of the electrode is inserted into the cable socket by pressure, ensuring a firm mechanical contact and stable contact impedance throughout the recording.
The 10-electrode configuration supports the arrangement of 12 leads of the standard electrocardiographic recording, allowing capture of the limb and precordial leads necessary for a complete diagnosis. Being a replacement part, it exactly reproduces the characteristics of the original cable of recorder 54300, so replacement requires no modification or additional adapters: simply remove the worn cable, connect the new one and check the correct insertion of each button-type electrode before use.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 54303 |
| SKU Cahnos | GM54303 |
| Compatible equipment | Holter ECG recorder 54300 (replacement) |
| Electrode configuration | 10 button-type electrodes |
| Supported leads | 12 leads |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | Z12050385 |
| EAN | 6947437903686 |
4. Equivalences and Cross-References
Reference 54303 is the designated replacement code for the button-type ECG lead wire of the Holter recorder 54300, according to the Product_DB catalogue of Cahnos. No equivalent references from other manufacturers have been found in verified sources that replace this cable 1:1, since the number of electrodes, the terminal type (button) and the equipment-side connector must exactly match the recorder 54300. Any substitution by a generic cable must be validated field by field (number of electrodes, terminal type and equipment connector) against the manufacturer’s technical data sheet before use in procurement; consult the technical department of Cahnos to confirm exact compatibility with your equipment.
5. Selection tips and variants of interest
Verify the recorder socket: this replacement is indicated for the Holter ECG recorder 54300; confirm the exact model of your equipment and the number of electrodes of your current cable (10 button-type electrodes) before proceeding with replacement.
Check the electrode terminal: this cable uses button-type connection (button); if your practice uses tab electrodes (TAB) for alligator clips or snap electrodes (snap), consider in Cahnos the range of disposable ECG electrodes and the connection adapters suitable for your cable inventory.
Cable maintenance: periodically inspect the electrode sockets and the equipment-side connector; cleaning must be carried out according to the manufacturer’s instructions for use to preserve signal quality and prolong the service life of the replacement.
For volume orders, complete sets or tenders, contact the technical-commercial department of Cahnos indicating the exact model of the recorder and the serial number of the equipment.