Description
1. Introduction
The non-magnetic stethoscope R-MN-20 is the essential auscultation instrument for any diagnostic imaging department working with MRI equipment. Its fully non-magnetic design —with a flat aluminium chest piece— makes it the safe choice for listening to the patient’s cardiac, respiratory and vascular sounds inside the MRI room, without risk of projectile effect or degradation of image quality. A professional, lightweight and durable solution designed for radiology, anaesthesia, critical care and diagnostic imaging consultations.
2. Technical explanation of the equipment
Auscultation in an MRI environment poses a serious technical challenge: conventional stethoscopes incorporate ferromagnetic metal components that can be violently attracted by the equipment’s magnetic field (projectile effect) and, in addition, distort the homogeneity of the field and degrade the image. This stethoscope is manufactured with non-ferromagnetic materials: the flat chest piece is made of aluminium and the whole assembly is free of steel, springs or magnets, so it can be used next to the magnet without compromising patient or staff safety, and without electromagnetic interference.
As it is a 100 % passive acoustic transmission instrument, it requires no batteries, electronics or calibration: the chest piece picks up vibrations from the internal organs and the Y-tube conducts them to the ear tips. This mechanical reliability makes it especially recommended for rooms where no electronic device should be introduced, and its corrosion-resistant aluminium guarantees a long service life with minimal maintenance.
3. Technical Specifications
Data verified against the product technical data sheet (document R-MN-20 A-MAGNETIC STETHOSCOPE).
| Characteristic | Technical data |
|---|---|
| Reference (SKU) | R-MN-20 |
| Instrument type | Non-magnetic acoustic stethoscope for MRI |
| Chestpiece | Flat, aluminium (dark grey), non-ferromagnetic |
| Chestpiece diameter | 47 mm |
| Tubing | Y-shaped, grey |
| Material | Lightweight, corrosion-resistant aluminium; free of ferromagnetic components |
| Compatibility | Approved for use in MRI rooms (MRI/RM) without electromagnetic interference |
| Operating principle | Passive acoustic transmission, no batteries or calibration |
| Type of use | Reusable, multiple uses |
| Presentation | Unit in decorative cardboard box |
| Application | Patient auscultation inside the MRI room; radiology, anaesthesia and diagnostic imaging |
4. Equivalences and Cross-References
The following references have been cross-checked against official catalogues and product data sheets from each manufacturer (ima-x, Magmedix, Ocelco and AliMed/MRIMed). No official cross-reference table with 1:1 equivalents has been found published by any manufacturer for this product type; therefore, matches are classified as comparable by category, not interchangeable 1:1, and differences in geometry, material and length must be checked before use in specifications or tenders.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| ima-x (Germany) | Non-magnetic stethoscope (extended tubing) | IRM065 | Comparable by category (not interchangeable 1:1) | Same flat anodised aluminium chest piece of Ø 47 mm, but with extended 1100 mm neoprene tubing and 25 g weight; designed for auscultating the patient once positioned inside the magnet. Verified in the official ima-x catalogue. |
| Magmedix (USA) | MRI Non-Magnetic Stethoscope (Sprague-Rappaport) | 03-E1003 | Comparable by category (not interchangeable 1:1) | Lightweight non-magnetic stethoscope, latex-free and with high-sensitivity contact diaphragm; Sprague-Rappaport double-receptacle design, different geometry from the single flat chest piece of this model. Verified at authorised distributor (McKesson, ref. 1104845). |
| Ocelco (USA) | Dual Head Stethoscope – MRI Non-Magnetic | 278-240 | Comparable by category (not interchangeable 1:1) | Non-magnetic double-head chest piece designed for MRI rooms; double-piece configuration, dimensions and accessories differ from the single flat chest piece of the R-MN-20. Verified on the manufacturer’s official website. |
| MRIMed / AliMed (USA) | MRI Conditional Dual Sprague Rappaport Stethoscope | 2970011719 (formerly 920343) | Comparable by category (not interchangeable 1:1) | MR-conditional stethoscope up to 3 Tesla, latex-free, with interchangeable bells for patients of all ages; double-head Rappaport-type geometry versus the flat chest piece of this model. Verified on the official AliMed website. |
There is no equivalence table validated by the manufacturer for SKU R-MN-20; consult the technical department at Cahnos before using these references as equivalents in tender documents or bids. Each manufacturer uses its own nomenclature, so substitution must always be validated against the original technical data sheet.
5. Selection tips and variants of interest
Always validate the labelling of the complete set: before introducing any instrument into the MRI room, confirm that it is free of ferromagnetic parts, even in seemingly inert accessories. This model is suitable for standard MRI rooms; for very high field requirements (up to 7 Tesla) consult our technical department about the variants available on request.
Complete the room monitoring set: for monitoring vital signs during the examination, combine this stethoscope with the non-magnetic aneroid sphygmomanometer blood pressure monitor (ref. CAHSPHIGMO), designed for MRI up to 3 Tesla, with an adult cuff of 29 to 40 cm and a leather case. If you need to auscultate the patient already positioned inside the equipment, the non-magnetic stethoscope with extended tubing (ref. CAHIRM065, 1100 mm tube) will allow you to maintain a comfortable working distance from the magnet.
Care and maintenance: clean the chest piece and earpieces with a slightly damp cloth or a disinfectant solution suitable for medical equipment after each patient; do not immerse the stethoscope in liquids or expose it to intense heat to preserve the diaphragm and tubing. Remember that electronic devices, including digital blood pressure monitors with batteries, must always remain in the control room and never enter the scanning area.





Reviews