Description
1. Commercial Introduction
The terminal adapter (ref. 30842) is the manufacturer’s original accessory that allows you to connect your endoscope with an ACM, OLYMPUS or STRYKER light connection to the fibre optic (F.O.) cable. A small-format component but of great practical value, designed for endoscopy services, operating theatres, ENT clinics and diagnostic units that want to make the most of their cabling stock with optics from these manufacturers, maintaining optimal and stable illumination in each examination.
2. Technical explanation
In fibre optic illumination systems, the light beam travels from the cold light source to the endoscope, the optic or the instrument through fibre optic (F.O.) cables. Each manufacturer uses its own connection standard on the endoscope’s light connection, so it is not always possible to directly attach a cable from one brand to another’s optic. This adapter is inserted between the distal end of the fibre optic cable and the light connection of the ACM, OLYMPUS or STRYKER endoscope, providing the correct mechanical fit and optical alignment. A precise coupling prevents light leaks, slack and misalignments that would reduce the brightness of the field and worsen image quality, critical aspects in diagnostic and surgical procedures.
3. Technical Specifications
Terminal adapter designed for connecting optics with ACM / OLYMPUS / STRYKER standard to fibre optic cables. Class I medical device, sold in units of 1 piece.
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM30842 | Cable/optic adapter ACM – OLYMPUS-STRYKER (this product) | 1 pc |
Product data
| Value | Detail |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 30842 |
| SKU Cahnos | GM30842 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | V9099 |
| EAN | 8023279308426 |
| Product type | Terminal adapter for fibre optic cable |
| Compatibility | ACM / OLYMPUS / STRYKER endoscopes and fibre optic cables |
4. Equivalences and Cross-References
This adapter corresponds to the manufacturer’s original reference. 30842, supplied by Cahnos under SKU GM30842 (EAN 8023279308426). No reliable sources document 1:1 equivalents with adapters from other manufacturers for connection to fibre optic cables; it is recommended to always use the original accessory to ensure the fit and light transmission. It belongs to the family of terminal adapters for the end of the endoscope or optic:
| SKU | Description |
|---|---|
| GM30840 | Cable/optic adapter STORZ/LUT (ref. 30840) |
| GM30841 | Cable/optic adapter WOLF (ref. 30841) |
| GM30842 | Cable/optic adapter ACM – OLYMPUS-STRYKER (ref. 30842, this product) |
On the light source side, the GM30830-GM30837 series allows connecting the F.O. cables of the manufacturer to cold light sources from practically all manufacturers on the market: GM30830, GM30831 (STORZ – AESCULAP – MARTIN), GM30832 (WOLF – HENKE SASS – DYONICS – MEDICON – COMEG), GM30833 (OLYMPUS), GM30834 (ACMI) and GM30837 (PENTAX). The manufacturer’s surgical light F.O. cables are offered in references GM30818, GM30822, GM30823 and GM30826.
5. Selection tips and variants of interest
Before requesting this adapter, check the connection standard of your endoscope’s light connection: if your optic is ACM, OLYMPUS or STRYKER, the appropriate reference is GM30842; if it is WOLF, you should choose GM30841; if it is STORZ or LUT, GM30840. Also remember to check the connector on your light source and select the corresponding adapter from the GM30830-GM30837 series to complete the illumination set with your fibre optic cable. It is recommended to keep the ends and the coupling area clean and free of dust to preserve optical transmission and avoid loss of brightness. For large orders you can request a quote: contact our technical-commercial team to confirm availability and conditions.