Description
1. Introduction
The thermal paper block for AVALON cardiotocograph is the consumable that keeps the Philips / Hewlett Packard fetal monitors of the AVALON FM-20 and FM-30 series operational. Its 150 × 100 mm format with 150 sheets per block and red grid is designed for continuous recording of fetal heart rate (FHR) and uterine activity (IUP) during antepartum monitoring and labour. The presentation in a box of 20 blocks allows cost-effective and uninterrupted replenishment for delivery suites, obstetric clinics and maternal-fetal medicine units.
2. Technical Explanation
The AVALON series cardiotocographs record on thermochemical paper: the image is generated by contact of the thermal printhead on the heat-sensitive layer of the paper, without the need for ink, toner or ribbon. For the recording to be clinically interpretable, the paper must have a pre-printed reference grid that allows assessment of the amplitude of contractions (intrauterine pressure scale, 0-100 mmHg) and fetal heart rate (FHR scale, 30-240 lpm), as well as the recording speed in mm/min.
This block incorporates a stop cell (stop signal) on the last sheet to warn of the end of the block, and its Z-fold facilitates continuous paper feeding, preventing jams, and also allows subsequent filing of the recording in the clinical record.
3. Technical Specifications
| Reference Cahnos (SKU) | 0553174 |
| Equivalent original reference | Philips / HP M1910A · 989803105491 |
| Compatible models | Philips / HP M1350A, M1350B, M1350C, M1351A, M1353A, M2922A (FM-2), M2702A (AVALON FM-20), M2703A (AVALON FM-30), M1910A |
| Block dimensions | 150 mm (width) × 100 mm (length) × 150 sheets |
| Format | Z-fold paper (z-fold), thermochemical |
| Grid colour | Red |
| Printed scale | FHR 30-240 lpm · IUP 0-100 mmHg |
| Stop cell | Yes (stop signal on the last sheet) |
| Print technology | Thermal printhead (thermochemical, ink-free) |
| Commercial presentation | Box of 20 blocks |
| Regulatory classification | Class I (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | 5 years after printing (see product instructions) |
| Storage | 5 °C – 40 °C, cool and dry place; avoid direct sunlight and excessive humidity |
4. Equivalences and Cross-References
There is no equivalence table validated by the equipment manufacturer that authorises third-party consumables for the original M1910A model; the following references are offered as functional comparisons verified in catalogues of manufacturers or authorised distributors and must be confirmed with the technical department before use in tendering.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Danlee Medical (USA) | Philips M1910A Compatible ECG Fetal Monitoring Recording Paper | PRM-CAA-7600185 | Comparable by category (not interchangeable 1:1) | Same format 150 × 100 mm × 150 sheets, Z/F-fold with stop signal on the last page; orange grid (the Cahnos one is red). The manufacturer declares equivalence to the Philips M1910A / 989803105491. Confirmed in the manufacturer’s data sheet. |
| PCI (recording paper manufacturer, USA) | Fetal Monitor Paper (generic compatible with M1910A) | M1910A (item PCI) | Comparable by category (not interchangeable 1:1) | 150 × 100 mm, 150 sheets per pack, 40 packs per box, orange grid with stop signal; declared compatible with FM-2, M1350A/B/C, M1351A, M1353A, M2922A, M2702A, M2703A, M2925A, M2704A and M2705A. Confirmed in the MedSource distributor catalogue. |
The references Nissha 7625114 and 30748696 are cited by Danlee Medical as equivalent to the Philips M1910A / 989803105491, but they could not be verified in a technical data sheet from the manufacturer Nissha itself; they are considered pending confirmation and must not be used in tendering without prior verification.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
Always check the grid colour: this data sheet corresponds to a red grid. Philips markets the original M1910A with an orange grid, while the version with a green grid corresponds to reference M1911A. Before replacing one consumable with another, confirm on the equipment which grid colour is programmed or readable for your service, as the pre-printed scale must match the one configured on the monitor.
Check the folding format: this block is Z-fold with a stop cell, the standard format for AVALON FM-20/FM-30. If your equipment uses a continuous roll, it is not interchangeable without mechanical adaptation.
Variants of the same family at Cahnos: fetal thermal block with green grid for AVALON FM-20/FM-30 (ref. 0553079, equivalent M1911A) and thermal block for fetal monitor Sonicaid MERIDIAN 800 / FM 800 / BD 4000 / BD 4002 (ref. 0553164).
Storage: store the blocks in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the quality of the trace and the stability of the clinical record. For institutional orders or tenders, contact our technical-commercial department to confirm compatibility and supply conditions.