Description
TOCO catheter for ECOtwin – Measurement of uterine dynamics for CTG monitoring
1. Introduction
The TOCO catheter for the ECOtwin fetal monitor is the original accessory from Bistos (distributed via medical ECONET GmbH) designed for non-invasive detection of uterine contractile activity during pregnancy and labour. In combination with the cardiotocographs ECOtwin LED and ECOtwin LCD, it enables simultaneous monitoring of uterine contractions and fetal heart rate, thus providing a complete and reliable cardiotocographic (CTG) assessment. It is the recommended solution for gynaecologists, obstetricians, midwives and nursing staff who require precise measurement of uterine dynamics both in antenatal checks and in the delivery room, whether as a spare catheter in the event of a fault or as an additional unit to expand clinical capacity.
2. Technical explanation of the accessory
Cardiotocography (CTG) simultaneously records fetal heart rate (FHR), captured by Doppler ultrasound catheters, and uterine contractile activity, measured by the external tocography catheter TOCO. This catheter detects the mechanical changes occurring in the abdominal wall during each contraction and transmits the signal to the monitor, which processes it and displays it on the tocography curve alongside the fetal heart rate trace. The values can be viewed on the device screen and documented via the integrated recorder. Its water-resistant design allows easy hygienic cleaning between patients, and its robust construction ensures continuous, reliable use in the daily routine of the consulting room and the labour ward.
3. Technical specifications and available references
| Product | External tocography (TOCO) catheter for ECOtwin CTG system |
| Brand | Bistos |
| Manufacturer / original distributor | Bistos (via medical ECONET GmbH) |
| Function | Non-invasive measurement of uterine contractile activity (tocography / TOCO) |
| Measurement | Detection of mechanical changes in the abdominal wall during contractions |
| Compatibility | ECOtwin LED · ECOtwin LCD |
| Design | Water-resistant (easy hygienic cleaning) |
| Construction | Robust, for daily use in practice and clinic |
| Application | Antenatal and intrapartum monitoring (CTG), obstetric consultations, clinics and delivery suites |
| Intended use | Spare catheter (Ersatz) or additional catheter for the CTG system |
| Source category | Fetal · Accessories (Zubehör) |
| Original catalogue | — |
Available references
| Reference Cahnos (SKU) | MEC36.70-3495 |
| Manufacturer reference (medical ECONET) | 36.70-3495 |
4. Equivalences and Cross-References
This TOCO catheter belongs to the original accessories line of the CTG ecosystem from Bistos distributed by medical ECONET GmbH and is marketed under references MEC36.70-3495 (SKU Cahnos) and 36.70-3495 (manufacturer’s article number). It is the tocography catheter included in the standard accessory set of the cardiotocographs ECOtwin LCD (Ref. 35.71-3480) and ECOtwin LED (Ref. 35.71-3490), making it directly compatible with both devices. There is no manufacturer-validated equivalence table authorising replacement with TOCO catheters from other manufacturers: as this is a system-specific transducer, the compatibility of the connector and signal with the specific monitor must be verified before considering any alternative.
Complementary accessories and consumables from the same range in the Cahnos catalogue:
| Reference | Product / compatibility |
| MEC36.70-3496 / 36.70-3496 | AST/TOCO catheter for ECOtwin and BT-350 CTG system |
| MEC36.70-3482 / 36.70-3482 | Event marker (Event Marker) for CTG ECOtwin, SMART 1, SMART 3, Insight and BT-300 |
| MEC36.70-3465 / 36.70-3465 | Carrying bag for ECOtwin and SMART fetal monitors |
| MEC21.09-1004 / 21.09-1004 | Stativ trolley Weiko for ECOtwin cardiotocograph (mobile stand) |
| 70.70-3454 | CTG thermal paper for ECOtwin, SMART 7 and SMART 9 monitors |
| 35.71-3480 / 35.71-3490 | Fetal cardiotocographs ECOtwin LCD and ECOtwin LED |
5. Selection tips and variants of interest
Verify the exact model of your monitor before purchasing the catheter: this TOCO catheter is indicated for the CTG systems ECOtwin LED and ECOtwin LCD. If your facility has one of these devices, this catheter is the recommended option as an original spare or as an additional unit for examination rooms, labour bays and antenatal monitoring points. To complete the CTG monitoring station, you can combine this catheter with the ECOtwin event marker (Ref. MEC36.70-3482), CTG thermal paper (Ref. 70.70-3454), transducer fixation belts and ultrasound transmission gel. If you need to move the equipment between consulting rooms or homes, the carrying bag (Ref. MEC36.70-3465) and the Weiko stand trolley (Ref. MEC21.09-1004) complete the solution. B2B product sold on quotation: for institutional orders, tenders or volume conditions, contact our technical-commercial department.



![[DISCONTINUED] CERVIBLOCK Paracervical anaesthesia needle 30G x 6 mm with Luer-Lock connector – Box of 30 sterile units (Ref. 720210)](https://www.cahnos.com/wp-content/uploads/720209-CERVIBLOCK-AGUJAS-PARA-ANESTESIA-PARACERVICAL-1-300x300.jpg)

Reviews