Description
1. Introduction
The portable fetal Doppler D2005 (Ref. GM29505) is a compact, lightweight, high-sensitivity pocket monitor designed for routine detection and monitoring of the fetal heartbeat in the clinic. Thanks to its waterproof 2 MHz catheter and its internal heart rate processor, it is the reference tool for primary care physicians, midwives, obstetricians and nursing staff in routine prenatal care, emergencies and home care.
2. Technical explanation of the equipment
The device uses continuous-wave Doppler ultrasound technology: the 2 MHz catheter (narrow-beam 2-crystal transducer) emits ultrasound waves that, when reflected by the movement of fetal cardiac structures, generate an audible signal and a numerical reading of the fetal heart rate (FCF). The internal signal processing minimises noise artefacts and allows the FCF to be displayed on a 3-digit LCD screen, with an accuracy of ±2 lpm and a resolution of ±1 lpm. The audio signal is heard through the built-in speaker or optional headphones, with an adjustable level via a rotary volume control.
The catheter is completely waterproof and the electronics are sealed, which facilitates cleaning and disinfection between patients and allows its use in humid environments. The device can detect the fetal heartbeat from approximately week 10 of gestation, locate the placental position (helping in the early diagnosis of placenta praevia), assess umbilical cord blood flow and assist in the diagnosis of multiple pregnancies.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Ultrasound frequency | 2 MHz continuous wave |
| Transducer | Narrow 2-crystal beam |
| Output power | <10 mW/mm² SATA |
| Audio response | 300 Hz – 1 kHz (autocorrelator) |
| Fetal heart rate (FHR) | 50–210 bpm; resolution ±1 bpm, accuracy ±2 bpm |
| Controls and indicators | Specification |
|---|---|
| Keys | 1 button (on/off) |
| Controls | Rotary volume |
| Indicators | 3-digit FHR LCD display, FHR pulse icon and low battery icon |
| Power supply and outputs | Specification |
|---|---|
| Power supply | 9 V alkaline manganese battery (not included) |
| Estimated battery life | 8 hours |
| Audio output | For optional headphones |
| Serial interface | RS232 – 3.5 mm jack |
| Physical characteristics | Specification |
|---|---|
| Material | ABS / Noryl |
| Measurements | 150 mm × 75 mm |
| Weight | 295 g (with transducer) |
| Safety classification | Class I Type B – IEC 60601-1 0120 |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | Z12080103 |
| GMDN | 34040 |
| EAN | 5060337640060 |
4. Equivalences and Cross-References
This device is part of the family of pocket fetal Dopplers with FCF display. There is no official 1:1 equivalence table published by the manufacturer; the following references are classified as comparable by category and must be validated field by field (catheter frequency, presence of display, waterproofing and accessories) before any substitution:
| Manufacturer / Brand | Model / Family | Reference | Equivalence level |
|---|---|---|---|
| Catalogue Cahnos | Foetal Doppler D2003 (with display, standard catheter) | GM29503 | Same family (variant without waterproof catheter) |
| Catalogue Cahnos | Foetal Doppler G2002 (fixed probe, without FHR display) | GM29502 | Same family (audio-only version) |
| ECOsound | Fetal Doppler with LCD screen and 2 MHz waterproof catheter | 35.71-2600 | Comparable by category (not interchangeable 1:1) |
| Huntleigh Healthcare | Sonicaid FD1 / D920 | FD1, D920 | Comparable by category (not interchangeable 1:1) |
| UltraTec / AB Medica | PD1dwr / fetatrack DD250 | PD1dwr, DD250 | Comparable by category (not interchangeable 1:1) |
There is no equivalence table validated by the manufacturer that cross-references this item with other brands; please consult the technical department at Cahnos before using these references in tenders or bids.
5. Selection tips and variants of interest
The D2005 is the recommended option when visual reading of the fetal heart rate is needed along with a waterproof catheter, especially in humid environments, water births or when rigorous cleaning between patients is prioritised. Its 2 MHz catheter offers good penetration, making it also suitable for patients with a higher body mass index.
If waterproofing is not a requirement, the D2003 version (Ref. GM29503) from the same family offers the same display features with a standard catheter. For exclusively auscultation use without a display, consider the G2002 (Ref. GM29502). If connected monitoring is sought, the IMAMI series from Unicare (Refs. IMAMI10, IMAMI20, IMAMI40) incorporates Bluetooth and a mobile app. Remember that the 9 V battery and headphones are not included and must be ordered separately, as well as the ultrasound transmission gel.