Description
1. Professional Holter ECG analysis with artificial intelligence assistance
The AI-ECG Tracker (Ref. 54315) is an advanced diagnostic analysis system for dynamic electrocardiograms designed for professional use. It is supplied as optional certified software for medical devices and is designed to integrate into the workflow of your diagnostic unit, cardiology department or Holter service: it completes the dynamic ECG analysis, guides arrhythmia detection and allows the cardiologist to edit, modify and confirm the final interpretation.
With a diagnostic accuracy of 95.2%, this software provides advanced analysis functions that turn the Holter recording into a reliable, reproducible and documentable clinical report, without relying on manual interpretation of minutes of tracing.
2. Technical Explanation
The AI-ECG Tracker software performs a complete diagnostic analysis of the dynamic ECG, suitable for evaluating electrocardiographic data from adult patients and for detecting arrhythmic cardiac disorders. The system automatically processes the Holter recording and presents the result with artificial intelligence support that guides the classification of complexes and abnormalities, always keeping the final clinical decision in the hands of the cardiologist, who can edit, modify and confirm the diagnosis.
Its advanced analysis functions include template editing, flutter and atrial fibrillation analysis, heart rate variability (HRV) analysis, heart rate oscillation analysis, P-wave superposition analysis and ST segment analysis, among other advanced assessment tools.
3. Technical Specifications
Data verified against the manufacturer’s catalogue (Product_DB.csv):
| Value | Specification |
|---|---|
| Product | AI-ECG Tracker – Dynamic ECG (Holter) analysis software for professional use |
| Manufacturer | GIMA |
| Manufacturer reference | 54315 |
| Sales unit | 1 unit |
| Device type | Medical device (software for medical device) |
| Device class | II A |
| CND | Z12050482 |
| GMDN | 41651 |
| EAN | 6971049341987 |
| Intended use | Evaluation of ECG data from adult patients and detection of cardiac arrhythmia-type abnormalities |
| Diagnostic accuracy | 95.2 % |
| Advanced functions | Template editing; flutter and atrial fibrillation analysis; HRV analysis; heart rate oscillation analysis; P-wave superposition analysis; ST segment analysis |
4. Equivalences and Cross-References
The AI-ECG Tracker is proprietary software, designed for the manufacturer’s cardiac monitoring ecosystem. No published equivalence table has been identified in reliable sources that authorises a 1:1 cross-reference of this licence with analysis software from third-party manufacturers: each system (e.g. CardioDay from GE, Cubeholter from Cardioline) uses its own algorithms and formats, so any comparison must be understood as comparable by category and not interchangeable 1:1. Consult the technical department of Cahnos before using this software with recorders from other brands.
In the Cahnos catalogue, this licence is complemented by the ambulatory recording park of the same line, such as the long-duration Holter ECG Cardio M (Ref. 30.90-9543) and the 12-channel resting electrocardiographs Cardio M PC/USB (Ref. 30.90-9500), Cardio M PC/NET (Ref. 30.90-9501) and Cardio M-PC/NET/ERGO (Ref. 30.90-9502), which share a digital cardiovascular diagnostic workflow.
5. Selection tips and variants of interest
Verify the software compatibility with your Holter recorder: confirm with the manufacturer or with the technical department of Cahnos that your recorder is compatible with the AI-ECG Tracker (Ref. 54315) before placing the order, indicating the exact model of your Holter fleet.
Equip the analysis stations: the workstation must meet the recommended system requirements to ensure smooth processing of long recordings and report generation.
Complete the monitoring chain with quality consumables: to obtain clean recordings, use specific Holter electrodes from the Cahnos catalogue, such as the paper electrode with solid gel Ø 55 mm (Ref. 16003), the non-woven fabric electrode with liquid gel 55 mm (Ref. 15552) or the solid gel foam electrode for Holter and stress (Ref. 0590028), accompanied by proper skin preparation (Ref. 10165 or 16656).
For multi-recorder installations, staff training or integration with the centre’s health information system, contact the technical-commercial department of Cahnos for fleet configuration and volume conditions. For large orders you can request a quote.