We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Single-Patient Gas Pathway Adapter for Capnograph 33829 – Original Spare Part (Ref. 33830)

12,83 €

Single-patient gas pathway adapter (ref. 33830), original spare part designed for the capnograph Ref. 33829 (SKU Cahnos GM33829). This accessory allows the hygienic and rapid replacement of the sampling path between the patient and the capnography equipment, ensuring continuous and reliable measurement of exhaled carbon dioxide (EtCO2) and respiratory rate in adults and paediatric patients. Low-consumption spare part, ideal for clinics, emergency care, medical transport, anaesthesia and postoperative care. For large orders you can request a quote: consult our technical-commercial team for B2B conditions and availability.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33830

Description

1. Introduction

The single-patient gas pathway adapter (ref. 33830) is the original spare part for the bedside capnograph Ref. 33829. Designed for single-patient use, it keeps the sampling circuit in optimal hygiene and performance conditions, preventing cross-contamination between patients and extending the equipment’s service life without the need to purchase a new capnograph. A practical and economical solution for hospitalisation, emergency care, anaesthesia, cardiopulmonary resuscitation, intensive care and medical transport.

2. Technical explanation

The capnograph Ref. 33829 uses the mainstream (in-line) measurement method to quantify end-tidal carbon dioxide (EtCO2) and airway respiratory rate (AwRR). The device connects to the patient’s respiratory tract via an air adapter and a respiratory connection tube; the gas pathway adapter is the intermediate element that channels the exhaled gas flow towards the capnograph’s optical sensor. As a single-patient component, it must be replaced between patients and at any sign of deterioration, condensation or blockage to ensure stable readings and reliable ventilatory monitoring in adults and paediatric patients.

3. Technical Specifications

Characteristic Specification
Product type Single-patient gas pathway adapter (spare part for capnograph)
Manufacturer GIMA
Manufacturer reference 33830 (SKU Cahnos: GM33830)
Compatibility Capnograph Ref. 33829 (mainstream method, EtCO2 and AwRR)
Use Single patient
Sales unit 1 pc
Device type Not a medical device (not a health product)
EAN 8023279338300

Available references

Reference Description
33830 Single-patient gas pathway adapter for capnograph 33829 (this product)
33829 Capnograph (adult/paediatric) with gas pathway adapter included and manual (GB, IT)

Prices are not shown on the datasheet. For large orders you can request a quote. Contact our technical-commercial department for availability and B2B supply conditions.

4. Equivalences and Cross-References

Reference 33830 corresponds to the original code for the single-patient gas pathway adapter of the capnograph 33829, as listed in the Product_DB catalogue. Within the same capnography family from the manufacturer, the portable capnograph-oximeter PC-900B (ref. 33698) comes as standard with adult airway adapters, sampling lines and nasal CO2 cannulas, whose consumables are not interchangeable with those of this reference without prior verification of the connector and the sampling method (mainstream vs sidestream). No official equivalence table cross-referencing this adapter with parts from other manufacturers has been found in reliable sources; before replacing it with an alternative accessory, confirm the measurement method and the exact coupling of your capnograph with our technical-commercial department.

5. Selection tips and variants of interest

Verify that your device is the capnograph Ref. 33829 before requesting this spare part: the 33830 adapter is specific to the in-line (mainstream) measurement method of that model. Keep at least one spare part per active device, as it is single-patient and replacement is periodic, avoiding interruptions in monitoring. For measurement in patients requiring sidestream sampling, consider the capnograph-oximeter PC-900B (ref. 33698) and its associated consumables (sampling lines, nasal cannulas and water filters). Contact the technical-commercial team at Cahnos to plan the continuous supply of spare parts and confirm compatibility and B2B conditions.

Additional information

Manufacturer reference

33830

Product type

Single-patient gas pathway adapter (spare part)

Compatibility

Capnograph ref. 33829 (mainstream method, EtCO2 and AwRR)

Use

Single patient

Device type

No medical device

EAN

8023279338300

Presentacion

Unit

Documentation

📄 DatasheetEnglish PDF

Reviews

There are no reviews yet.

Be the first to review “Single-Patient Gas Pathway Adapter for Capnograph 33829 – Original Spare Part (Ref. 33830)”

Your email address will not be published. Required fields are marked *