Description
1. Commercial Introduction
The portable capnograph (ref. 33829) is the compact and reliable solution for respiratory monitoring in clinical and prehospital settings. Designed for adult and paediatric patients, it allows continuous, non-invasive checking of end-tidal carbon dioxide (EtCO2) and respiratory rate (AwRR), two essential parameters for assessing patient ventilation. Its small size (just 92 g) and colour LCD screen make it a manageable device, ideal for anaesthesia, cardiopulmonary resuscitation, emergency care, ICU and the postoperative period.
2. Technical explanation of the equipment
The device uses the mainstream method to measure end-tidal carbon dioxide (EtCO2) and airway respiratory rate (AwRR). This technique allows detection of pulmonary ventilation function and reflects the condition of circulation and pulmonary blood flow, as well as alveolar ventilation indirectly. It connects to the patient’s respiratory tract via an air adapter and a respiratory connection tube.
- Audible and visual alarm with mute function.
- Limit-exceeded alarm for EtCO2 and respiratory rate.
- Warning for ‘adapter disconnected’.
- Zero calibration can be performed by the user.
- Atmospheric pressure and temperature compensation.
- Suitable for use in high-altitude environments.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| EtCO2 | Measurement range: 0-150 mmHg; resolution: 1 mmHg |
| AwRR | Measurement range: 2-150 rpm; resolution: 1 rpm |
| Display | 1.3-inch colour LCD display |
| Battery life | 4 hours |
| Size – weight | 59x56x59.5 mm – 92 g (with batteries) |
| Protection | Applied part type BF, IP22 |
| Power supply | 2 AAA batteries (included) |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 33829 |
| SKU Cahnos | GM33829 |
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | II A |
| CND | Z12030285 |
| EAN | 6945040104681 |
4. Equivalences and Cross-References
Reference 33829 is the original code for this portable mainstream capnograph, as listed in the Product_DB catalogue (SKU Cahnos GM33829). No official equivalence table validated by the manufacturer is available to cross-reference this device with third-party capnographs; the measurement method (mainstream), measurement range and accessories (adult/child adapter and connection tube) are manufacturer-specific and must not be replaced without prior technical validation.
Within the Cahnos catalogue, the capnograph-oximeter PC-900B (ref. 33698, SKU GM33698) and the EtCO2 capnography kit for the Rescue Life 9 defibrillator (ref. 55521, SKU GM55521) can be considered related references from the same respiratory monitoring family; the EtCO2 capnography module for the K15 multiparameter monitor (ref. 35310, SKU GM35310) requires modules 33796 or 33797. For any replacement or fleet expansion, contact the technical-commercial department of Cahnos to confirm exact compatibility.
5. Selection tips and variants of interest
This capnograph is indicated for services that require rapid and continuous verification of ventilation and perfusion in adult and paediatric patients: anaesthesia, cardiopulmonary resuscitation, prehospital care, ICU and postoperative. Its operation with 2 AAA batteries and its 4-hour battery life make it suitable for transport and out-of-hospital care.
- Confirm your service configuration: if you also require pulse oximetry (SpO2), consider the PC-900B family (ref. 33698).
- Periodically review the airway accessories (adult/child adapter and connection tube) and replenish consumables in accordance with the manufacturer’s indications.
- Perform the user-permitted zero calibration and take advantage of the automatic atmospheric pressure and temperature compensation for use at altitude.
- For fleet provisions or tenders, request a quote from our technical-commercial team stating reference 33829 (SKU GM33829) and the required volume of equipment.







Reviews