We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Portable Adult-Paediatric Capnograph | EtCO2 and Respiratory Rate Measurement (Ref. 33829)

617,50 €

Portable capnograph for adult and paediatric patients that measures end-tidal carbon dioxide (EtCO2) and respiratory rate (AwRR) using the mainstream method. Compact and lightweight (92 g), with 1.3-inch colour LCD screen, audible and visual alarms, user zero calibration and atmospheric pressure and temperature compensation, suitable for use at altitude. Ideal for anaesthesia, CPR, prehospital emergencies, ICU and postoperative. Includes adult/child airway adapter, AAA batteries and manual. Class II A medical device. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33829

Description

1. Commercial Introduction

The portable capnograph (ref. 33829) is the compact and reliable solution for respiratory monitoring in clinical and prehospital settings. Designed for adult and paediatric patients, it allows continuous, non-invasive checking of end-tidal carbon dioxide (EtCO2) and respiratory rate (AwRR), two essential parameters for assessing patient ventilation. Its small size (just 92 g) and colour LCD screen make it a manageable device, ideal for anaesthesia, cardiopulmonary resuscitation, emergency care, ICU and the postoperative period.

2. Technical explanation of the equipment

The device uses the mainstream method to measure end-tidal carbon dioxide (EtCO2) and airway respiratory rate (AwRR). This technique allows detection of pulmonary ventilation function and reflects the condition of circulation and pulmonary blood flow, as well as alveolar ventilation indirectly. It connects to the patient’s respiratory tract via an air adapter and a respiratory connection tube.

  • Audible and visual alarm with mute function.
  • Limit-exceeded alarm for EtCO2 and respiratory rate.
  • Warning for ‘adapter disconnected’.
  • Zero calibration can be performed by the user.
  • Atmospheric pressure and temperature compensation.
  • Suitable for use in high-altitude environments.

3. Technical Specifications

Parameter Specification
EtCO2 Measurement range: 0-150 mmHg; resolution: 1 mmHg
AwRR Measurement range: 2-150 rpm; resolution: 1 rpm
Display 1.3-inch colour LCD display
Battery life 4 hours
Size – weight 59x56x59.5 mm – 92 g (with batteries)
Protection Applied part type BF, IP22
Power supply 2 AAA batteries (included)

Product data

Manufacturer GIMA
Manufacturer reference 33829
SKU Cahnos GM33829
Sales unit 1 unit
Device type Medical device
Device class II A
CND Z12030285
EAN 6945040104681

4. Equivalences and Cross-References

Reference 33829 is the original code for this portable mainstream capnograph, as listed in the Product_DB catalogue (SKU Cahnos GM33829). No official equivalence table validated by the manufacturer is available to cross-reference this device with third-party capnographs; the measurement method (mainstream), measurement range and accessories (adult/child adapter and connection tube) are manufacturer-specific and must not be replaced without prior technical validation.

Within the Cahnos catalogue, the capnograph-oximeter PC-900B (ref. 33698, SKU GM33698) and the EtCO2 capnography kit for the Rescue Life 9 defibrillator (ref. 55521, SKU GM55521) can be considered related references from the same respiratory monitoring family; the EtCO2 capnography module for the K15 multiparameter monitor (ref. 35310, SKU GM35310) requires modules 33796 or 33797. For any replacement or fleet expansion, contact the technical-commercial department of Cahnos to confirm exact compatibility.

5. Selection tips and variants of interest

This capnograph is indicated for services that require rapid and continuous verification of ventilation and perfusion in adult and paediatric patients: anaesthesia, cardiopulmonary resuscitation, prehospital care, ICU and postoperative. Its operation with 2 AAA batteries and its 4-hour battery life make it suitable for transport and out-of-hospital care.

  • Confirm your service configuration: if you also require pulse oximetry (SpO2), consider the PC-900B family (ref. 33698).
  • Periodically review the airway accessories (adult/child adapter and connection tube) and replenish consumables in accordance with the manufacturer’s indications.
  • Perform the user-permitted zero calibration and take advantage of the automatic atmospheric pressure and temperature compensation for use at altitude.
  • For fleet provisions or tenders, request a quote from our technical-commercial team stating reference 33829 (SKU GM33829) and the required volume of equipment.

Additional information

Manufacturer

GIMA S.p.A.

Manufacturer reference

33829

Product type

Portable mainstream capnograph

EtCO2

0-150 mmHg; resolution 1 mmHg

Awrr

2-150 rpm; resolution 1 rpm

Measurement method

Mainstream

Display

1.3-inch colour LCD

Battery life

4 hours

Dimensions

59 x 56 x 59.5 mm

Weight

92 g (with batteries)

Power supply

2 AAA batteries (included)

Protection

Applied part type BF, IP22

Alarms

Audible and visual with mute

Included accessories

Adult/child airway adapter, AAA batteries and manual

CND code

Z12030285

EAN

6945040104681

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Tipo paciente

Adult, Paediatric

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Portable Adult-Paediatric Capnograph | EtCO2 and Respiratory Rate Measurement (Ref. 33829)”

Your email address will not be published. Required fields are marked *