We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

DEXA bone densitometer Dexxum T Quantum with fan-beam technology for dual femur, lumbar spine and dual forearm | Osteosys / medical ECONET | Ref. MEC25.40-3120

29.999,00 €

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

DXA bone densitometer Dexxum T Quantum from Osteosys (distributed by medical ECONET), a dual-energy X-ray absorptiometry system with fan-beam technology designed for practices, clinics and prevention centres seeking speed and a compact installation. It measures bone mineral density in the dual femur, lumbar spine (LWS) and dual forearm in just 20-30 seconds depending on the area, with minimal space requirements and very low radiation exposure for the patient. It includes additional abdominal fat analysis, T-Score, Z-Score and FRAX assessment, and an already activated DICOM interface for integration into the centre’s digital workflows. Product available on quotation.

Available on back-order

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC25.40-3120

You will also find it in

Description

DXA bone densitometer Dexxum T Quantum: fast and compact densitometric diagnosis

The Dexxum T Quantum is a modern DXA bone densitometer from the company Osteosys, distributed by medical ECONET GmbH, designed for surgeries, clinics and prevention and health centres that value very short examination times and an installation that takes up little space. It combines a compact structure with modern fan-beam technology, making it the ideal solution for centres with a high patient volume.

Its rapid measurement technique streamlines the daily practice routine and maintains high clinical throughput without compromising diagnostic reliability.

How fan-beam DXA technology works

The system uses DXA (dual-energy X-ray absorptiometry) technology with fan-beam geometry, the international reference technique for measuring bone mineral density (BMD) and diagnosing osteoporosis using the clinical indices T-Score and Z-Score, in accordance with the criteria of the World Health Organization (WHO).

Thanks to fan-beam technology, scans of the clinically relevant areas —dual femur, lumbar spine (LWS) and dual forearm— are completed in approximately 20 to 30 seconds depending on the area, while keeping the patient’s radiation exposure very low. In addition to classic bone densitometry, the system also enables additional measurement of abdominal fat, expanding its diagnostic capabilities in the field of prevention and health.

For a structured assessment of results, the system offers analysis parameters such as T-Score, Z-Score and FRAX assessment of fracture risk, and includes an already enabled DICOM interface that facilitates integration into the centre’s digital workflows and existing imaging systems.

Technical specifications

Available references

Reference Description
MEC25.40-3120 / 25.40-3120 DXA densitometry system Dexxum T Quantum (fan-beam) – Osteosys / medical ECONET

Technical features

Characteristic Specification
Brand / Manufacturer Osteosys (distributed by medical ECONET GmbH)
Manufacturer references MEC25.40-3120 / 25.40-3120
Technology DXA – dual-energy X-ray absorptiometry
Scan type Fan-beam
Measurement zones Dual femur, lumbar spine (LWS) and dual forearm
Additional measurement Abdominal fat
Measurement time Approx. 20-30 seconds depending on the measurement area
Analysis parameters T-Score, Z-Score and FRAX fracture risk assessment
Interface DICOM (enabled)
Radiation Minimum patient exposure
Design Compact, low space requirement (practice and clinic)
Field of application Surgeries, clinics, osteoporosis units and prevention centres

Note: the specifications correspond to the medical ECONET catalogue for the Dexxum T Quantum platform; confirm the final configuration and the declaration of conformity of the supplied batch.

Equivalences and cross-references

The Dexxum T Quantum corresponds to the compact fan-beam DXA system from the medical ECONET catalogue (references MEC25.40-3120 / 25.40-3120), within the DXA systems category of the Osteosys range, alongside other platforms from the same manufacturer such as inus|D, Excellus and Primus. The systems from the same family and compatible accessories available at Cahnos are listed below:

Manufacturer / Brand Model / Reference Equivalence level Observations
Osteosys / medical ECONET Excellus Half-Body – MEC25.40-4000 / MEC25.40-4100 Higher range of the same family (not 1:1 interchangeable) Half-body DXA system with body composition analysis; verify technical data sheet and configuration.
Osteosys / medical ECONET Primus Full-Body – MEC25.40-5000 Higher range of the same family (not 1:1 interchangeable) Full-body DXA system with advanced clinical functions (LVA, FRAX, optional TBS).
Osteosys / medical ECONET Primus Short Body – MEC25.40-6000 Compact variant of the same family (not 1:1 interchangeable) Reduced scan area, dimensions and weight.
Osteosys / medical ECONET inus|D – Ref. 25.41-3100 Complementary / axial DEXA category Pencil-beam DXA system for lumbar spine and femur; longer scan times.
Osteosys / medical ECONET Daily Test Phantom – MEC80.40-3110 Compatible accessory Daily control phantom for inus|D, Dexxum T Quantum, Excellus and Primus.
BWH Rigid carrying case for DXA phantom – 26.98-9199 Compatible accessory Protected transport and storage of the DXA test phantom.

There is no manufacturer-validated equivalence table cross-referencing this equipment with DXA systems from other manufacturers; any comparison must be treated as functional by category and verified on a case-by-case basis (measurement areas, times, accuracy, interface and regulatory classification). For replacements or tenders, please consult the technical-commercial team at Cahnos.

Selection tips and variants of interest

Limited space: if your practice or centre has little space, the Dexxum T Quantum offers fan-beam DXA diagnosis with a compact footprint, without compromising the classic measurement areas of dual femur, lumbar spine and dual forearm.

High patient volume: with scan times of approximately 20-30 seconds per area, the system enables efficient patient flow management in daily routine.

Quality control: incorporate daily verification with the Daily Test Phantom for DXA systems (ref. MEC80.40-3110) and protect the phantom during transport with the specific rigid case (ref. 26.98-9199), both available from Cahnos and compatible with the Dexxum T Quantum platform.

Prevention and screening: for screening and prevention programmes, the QUS inus|S (ref. 25.41-1300) and inus|B (ref. 25.41-3300) systems complement the care pathway alongside confirmatory axial DEXA diagnostics.

Equipment and tenders: for volume orders, complete equipment packages or public tenders, contact our technical-commercial team, who will advise you without obligation. Product available on quotation.

Additional information

Manufacturer reference

25.40-3120

Manufacturer

Osteosys (distributed by medical ECONET GmbH)

References

MEC25.40-3120 / 25.40-3120

Technology

DXA – dual-energy X-ray absorptiometry

Scan type

Fan-beam

Measurement zones

Dual femur, lumbar spine (LWS) and dual forearm

Additional measurement

Abdominal fat

Measurement time

Approx. 20-30 seconds depending on the area

Analysis parameters

T-Score, Z-Score and FRAX (fracture risk)

Interface

DICOM (enabled)

Radiation

Minimum patient exposure

Design

Compact, low space requirement

Field of application

Surgeries, clinics, osteoporosis units and prevention centres

Reviews

There are no reviews yet.

Be the first to review “DEXA bone densitometer Dexxum T Quantum with fan-beam technology for dual femur, lumbar spine and dual forearm | Osteosys / medical ECONET | Ref. MEC25.40-3120”

Your email address will not be published. Required fields are marked *