We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Replacement CM-PROBE catheter for bone densitometer 56800 – Radius and tibia (Ref. 56802)

5.985,00 €

Catheter CM-PROBE replacement for bone densitometer model 56800, designed for bone mineral density measurement in radius and tibia. Original manufacturer replacement part, sales unit of 1 unit (1 pc). Software licence 56805 is required for tibia measurement. Exclusively compatible with the 56800 equipment from the BDM densitometry range.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM56802

You will also find it in

Description

Replacement catheter for bone densitometer

The CM-PROBE (Ref. 56802) catheter is the manufacturer’s official replacement for the bone densitometer model 56800. Designed for diagnostic services, sports medicine clinics, traumatology, rheumatology and occupational health, it ensures the operational continuity of your peripheral ultrasound densitometry equipment, maintaining the reliability and metrological traceability of measurements.

Technical explanation

The catheter is the transducer element placed over the anatomical area to be examined to perform bone mineral density measurement by ultrasound. The CM-PROBE version is designed for measurements on radius and tibia with the 56800 densitometer. To enable tibia examination, the equipment software requires the 56805 licence; without it, measurement is limited to other areas enabled by the equipment configuration.

As an original replacement part, it ensures maximum compatibility with the equipment, prevents signal degradation and minimises downtime for the diagnostic service. It is recommended to handle it with care and follow the manufacturer’s maintenance instructions to extend its service life.

Technical specifications

Characteristic Detail
Manufacturer GIMA
Sales unit 1 pc
Parameter Specification
Manufacturer reference 56802
Product type Replacement catheter (CM-PROBE)
Compatible equipment Bone densitometer Ref. 56800
Measurement zones Radius and tibia
Licence required for tibia Yes, software licence 56805

Equivalences and cross-references

No equivalence table validated by the manufacturer is available for this replacement catheter; it is an original part designed specifically for model 56800. Consult our technical department before considering any substitution or compatibility with other densitometry equipment.

Related references from the same system:
– 56800: bone densitometer to which this catheter is attached.
– 56805: software licence required for tibia measurement.

Selection tips and variants of interest

Always verify reference 56802 when ordering this replacement for the 56800 densitometer and confirm that the equipment has licence 56805 if your examination protocol includes tibia measurement. Periodically check the condition of the catheter, cabling and connector, and perform equipment verification according to the manufacturer’s instructions to maintain measurement quality. If you need other accessories or consumables for your densitometer (gels, calibration phantom, thermal paper or software licences), consult our technical-commercial team.

Additional information

Manufacturer reference

56802

Product type

Replacement catheter CM-PROBE for bone densitometer

Compatibility

Bone densitometer model 56800

Measurement zones

Radius and tibia

Licence required

56805 (software licence for tibia measurement)

Presentacion

Unit

Documentation

📄 DatasheetEnglish PDF

Reviews

There are no reviews yet.

Be the first to review “Replacement CM-PROBE catheter for bone densitometer 56800 – Radius and tibia (Ref. 56802)”

Your email address will not be published. Required fields are marked *