Description
1. Commercial Introduction
The AUDIOTEST (electronic BOEL test) is a unique and simple auditory screening tool designed to check the hearing abilities of infants and to detect possible childhood hearing loss early, between 6 and 10 months of age. Battery-powered, lightweight and intuitive to operate with just two buttons, it is the perfect complement for paediatric, neonatology, ENT clinics and for hearing screening units that need a quick and reliable assessment of the child’s response to sound stimuli.
2. Technical explanation of the equipment
The BOEL test is the screening method used to assess children’s hearing abilities and to verify early response to a sound stimulus. The AUDIOTEST is manufactured based on the classic BOEL test, both in the ergonomics of its shape (it is held in the palm of the hand so that the child does not see it and is not distracted) and in the sound standards of the original bell panels.
The device emits two sound stimuli: a low-frequency low tone around 125-150 Hz and a high-frequency high tone around 5.0-5.1 kHz, equivalent to the bell panels of the BOEL test, with amplitudes of 86 dBA and 96 dBA respectively. This allows testing the child’s response at thresholds very significant for hearing. The test result is obtained by observing the child’s reaction to the stimulus, without requiring active cooperation.
3. Technical Specifications
The AUDIOTEST is an electronic hearing screening product that is very simple to use: just two buttons allow selection of the two stimulation frequencies. It requires no calibration or configuration and is battery-powered, making it fully portable and suitable for use in clinics and screening campaigns.
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | No medical device |
| EAN | 8023279335996 |
| Manufacturer reference | 33599 |
|---|---|
| SKU Cahnos | GM33599 |
| Product type | Electronic paediatric hearing test (auditory screening) |
| Stimulus 1 – low tone | Approx. 125-150 Hz (86 dBA) |
| Stimulus 2 – high tone | Approx. 5.0-5.1 kHz (96 dBA) |
| Recommended age | 6 to 10 months |
| Control | 2 buttons (frequency selection) |
| Power supply | Batteries (battery-powered) |
| Ergonomics | Designed to be held in the palm of the hand, not visible to the child |
| Manufacture | Italy (Italia) |
4. Equivalences and Cross-References
This product corresponds to the manufacturer’s original reference 33599 (catalogue name: BOEL TEST – electronic / AUDIOTEST), marketed by Cahnos as GM33599 (EAN 8023279335996). A direct 1:1 equivalence with other models from other brands has not been verified from reliable sources; as it is a screening instrument based on the BOEL method, any comparison must be checked point by point with the technical-commercial department of Cahnos before considering a replacement.
As similar references within the paediatric and infant audiometry catalogue, Cahnos offers the portable paediatric audiometer PA5 (Ref. 33601 – GM33601), for hearing screening in neonates and infants, and the Triangle Basic screening audiometer (Ref. 33619 – GM33619).
5. Selection tips and variants of interest
The AUDIOTEST is the right option for a quick and specific assessment of the infant’s hearing response in the clinic, without the need for complex audiometric equipment or the child’s cooperation. If your centre also requires a more complete hearing examination, you can complement this screening with the paediatric audiometer PA5 (Ref. 33601 – GM33601) or with screening/diagnostic audiometers from the range such as the Triangle Basic (Ref. 33619) or the Piccolo Basic (Ref. 33613). For large orders you can request a quote: consult our B2B technical-commercial team for advice on the most suitable equipment for your clinic’s needs and to receive a personalised quote.