8 MHz vascular catheter for V2000 Doppler (Ref. 33128) – Replacement transducer for arterial vascular diagnostics

304,00 €

8 MHz vascular catheter (ref. 33128) for the pocket V2000 Doppler: high-sensitivity replacement transducer for auscultating flow in superficial peripheral arteries and veins. Ideal for measuring the ankle-brachial index (ITB/ABPI), diabetic foot screening and rapid vessel localisation in emergency settings. 8 MHz continuous-wave frequency, compatible with the V2000 unit (code 33123); class II A medical device. Supplied in units of 1 pc. For large orders you can request a quote: consult availability and conditions with our technical-commercial department.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33128

Description

1. Commercial Introduction

The 8 MHz vascular catheter for the V2000 Doppler (ref. 33128) is the ideal replacement transducer to replenish or expand the equipment of your pocket V2000 Doppler. Designed for non-invasive vascular examination of superficial peripheral arteries and veins, this catheter allows healthcare professionals to locate vessels, auscultate blood flow and perform routine arterial screenings with total reliability, both in the clinic and in emergency, primary care, angiology or diabetic foot units.

2. Technical explanation of the equipment

The V2000 Doppler is a lightweight, high-sensitivity pocket echo-Doppler that operates using continuous-wave Doppler ultrasound technology. The catheter emits ultrasonic waves that, when reflected off moving red blood cells, generate a frequency change proportional to the flow velocity; an internal processor minimises noise artefacts and the signal is reproduced through the built-in speaker, whose output level is adjusted using the rotary volume control.

The frequency of the catheter determines the depth of examination: the 8 MHz catheter offers excellent resolution in superficial peripheral vessels (dorsalis pedis, radial, ulnar arteries) and in small-calibre or calcified arteries, making it the most common choice for measuring the ankle-brachial index (ITB/ABPI) and arterial screening in primary care. The V2000 unit accepts 2, 5 or 8 MHz catheters in continuous wave, with output power below 15 mW/cm² SATA and audio response from 300 Hz to 4 kHz.

3. Technical specifications and tables

Available references

Reference Code
Manufacturer reference 33128
SKU Cahnos GM33128
Compatible unit (Doppler) 33123 (V2000 Doppler, without catheter)

Catheter specifications

Characteristic Specification
Catheter type Vascular, continuous-wave Doppler
Frequency 8 MHz
Compatible equipment V2000 Doppler (code 33123)
Clinical indication Superficial peripheral vessels, ITB/ABPI, arterial screening, vessel localisation

Product data

Manufacturer GIMA
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II A
CND Z12059080
EAN 5060337640244

4. Equivalences and Cross-References

This 8 MHz catheter (ref. 33128) is the replacement transducer indicated by the manufacturer for the V2000 unit (code 33123), which is sold without a catheter. Within the same family of pocket vascular Dopplers, the V2005 (ref. 33120) and V2008 (ref. 33121) units incorporate a fixed 5 MHz and 8 MHz catheter respectively, so they can be considered similar references in the range.

As a comparable reference by category within the Cahnos catalogue, the portable vascular Doppler Hi-Dop (ref. 40.70-2200) includes three interchangeable catheters of 4, 5 and 8 MHz with an LCD screen for vascular screening. There is no 1:1 equivalence table validated by the manufacturer that cross-references this catheter with transducers from other brands (e.g. Dopplex/Huntleigh or Hadeco Smartdop); for any replacement or tender, always verify connector and electronics compatibility with your V2000 unit through our technical-commercial department.

5. Selection tips and variants of interest

For measuring the ankle-brachial index (ITB/ABPI) and examining superficial peripheral arteries, the 8 MHz catheter is the most widely used due to its resolution in small-calibre vessels. Reserve lower-frequency catheters for deeper vessels or limbs with oedema. Always check that your V2000 unit supports the catheter connection before placing the order, use specific ultrasound transmission gel and keep the catheter clean without subjecting the connector to immersion. For large orders you can request a quote: consult availability and conditions with our technical-commercial team at Cahnos.

Additional information

Manufacturer reference

33128

Frequency

8 MHz

Catheter type

Vascular (continuous wave)

Compatibility

Doppler V2000 (code 33123)

Application

ITB/ABPI, arterial screening, diabetic foot, vessel localisation

CND code

Z12059080

EAN

5060337640244

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF