Description
1. Reliable power for your CAS Medical 740 vital signs monitor
This rechargeable battery of 7.2V and 3.8Ah (Ref. 88888071) is the recommended replacement for the vital signs monitor CAS Medical 740 (also known as Casmed NIBP 740), a compact device widely used in hospital wards, emergency departments, intra-hospital transport and intensive care units. It is a nickel-metal hydride (Ni-MH) accumulator, cadmium-free and with very low memory effect, which restores the monitor’s full autonomy for successive patient assessments without the need for mains connection. It is the practical solution for maintenance departments, biomedical engineering and hospital purchasing teams looking for a traceable, proven-quality spare part at a very contained cost compared with the official replacement.
2. Technical explanation: how this battery works
The CAS Medical 740 monitor is a bedside and transport device that continuously measures the patient’s vital signs (ECG, oxygen saturation, non-invasive blood pressure and temperature). To ensure patient monitoring when the device is not connected to the mains, it incorporates an internal rechargeable battery that recharges automatically while the monitor remains plugged in. This battery of 7.2V / 3.8Ah (27.36Wh) delivers the nominal voltage and capacity required by the device. When autonomy is noticeably reduced or the monitor warns of low battery prematurely, it is time to replace the accumulator with this reference. Its installation is simple: it is inserted into the device’s battery compartment, without the need for tools or adapters.
3. Technical Specifications
| Characteristic | Specification |
| Reference (SKU) | 88888071 |
| Accumulator type | Ni-MH (nickel-metal hydride), rechargeable |
| Nominal voltage | 7.2 V |
| Nominal capacity | 3.8 Ah (3,800 mAh) |
| Energy | 27.36 Wh |
| Application | CAS Medical 740 vital signs monitor (Casmed NIBP 740) |
| Additional compatibility | CAS 740-1, CAS 740-2, CAS 740-2T, CAS 740-3, NIBP 730, NIBP 750 and monitor 940X (verify batch) |
| Original references it replaces | 03-08-0450, 03-08-0450-I, 6036, 120336, OM11377 |
| Approximate weight | 0.28 kg (according to distributor’s data sheet; compare with original part) |
| Indicative dimensions | 95 x 50 x 40 mm (according to distributor’s data sheet; compare with original part) |
| Rechargeable | Yes (automatic recharging with the monitor plugged in) |
| Use | Vital signs monitoring in hospitals, clinics, emergency departments and ICUs |
| Presentation | 1 unit |
Note: the weight and dimensions indicated come from the distributor’s data sheet; as this is a third-party replacement, it is recommended to compare dimensions, connector and cell configuration with the original battery before replacement.
4. Equivalences and Cross-References
The reference 88888071 is the commercial code under which Cahnos supplies this 7.2V / 3.8Ah Ni-MH battery for the CAS Medical 740 monitor. It corresponds to the replacement for the equipment’s original references 03-08-0450 (also listed as 03-08-0450-I) and its variants 6036, 120336 and OM11377, codes that appear consistently in multiple independent distribution sources linked to the Casmed 740, 750 and 940X monitors. There is no registration in GUDID or EUDAMED for this generic replacement; treat these codes as catalogue data and original equipment reference.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cameron Sino | Medical battery for Cas Medical 740 / 750 / 940X, NIBP 730 / 740 / 750 | CS-CMS740MD | Comparable by category (not interchangeable 1:1) | Ni-MH 7.2V / 3,800 mAh (27.36 Wh), dimensions 101.0 x 69.25 x 17.23 mm, weight 306-450 g depending on batch. Same chemistry, voltage and capacity but different pack dimensions and weight from those declared in the data sheet (95 x 50 x 40 mm / 0.28 kg); check compartment and connector against the specific device before replacing. Confirmed in the battery manufacturer’s data sheet. |
Other brands and homologous families identified in the sector for this category (Ni-MH 7.2V / 3,800 mAh battery for Casmed 740 / 750 / 940X) include TollCor replacements, cross-referenced P/Ns 03-08-0450-I, 120336, 6036, B11377, AS36036 and BH-7238-RC5P, and biomedical spare parts such as BatteryHawks; consult their technical data sheets before any replacement. There is no equivalence table validated by the equipment manufacturer (CAS Medical Systems) for this reference; consult the technical department before use in tenders. Before a replacement, the following must be verified one by one: voltage (7.2V), chemistry (Ni-MH), capacity, pack dimensions and connector against the specific device.
5. Selection tips and variants of interest
- Confirm the exact monitor model: this 7.2V / 3.8Ah battery is the one indicated for the CAS Medical 740 family and compatible 750 / 940X models. Do not use it in other vital signs monitors with different voltage or chemistry, even if the compartment may look similar.
- Respect the chemistry and voltage: do not use lithium-ion (Li-ion) batteries or other voltages (e.g., 10.8V or 12V packs) in this device, even if they fit physically.
- Compare with the original part: before replacing, verify the reference printed on the original battery (03-08-0450, 03-08-0450-I, 6036, 120336 or OM11377) and the compartment dimensions.
- Replace upon signs of wear: clearly reduced autonomy or low battery warnings within a few hours of charging indicate that the accumulator has reached the end of its service life.
- Always place orders by reference: quote the code 88888071 or the original equipment reference (03-08-0450) to avoid confusion with other batteries in the Casmed family.
- For mixed fleets: consult our catalogue of batteries for vital signs monitors; we stock spare parts for the Philips, GE Healthcare, Spacelabs, Mindray, Nihon Kohden and other families.





Reviews