Description
1. Reliable power for your Spacelabs Medical Qube monitor
At Cahnos we offer the spare battery for the Spacelabs Medical Qube (model 91390) vital signs monitor, reference Cahnos 88888909, corresponding to the original manufacturer reference 146-0142-00. This is a rechargeable lithium-ion (Li-ion) battery of 11.1 V and 7.8 Ah (86.58 Wh) that restores full autonomy to the device for continuous patient monitoring when the monitor is not connected to the mains power supply.
It is the ideal solution for biomedical engineering services, medical electronics maintenance and hospital purchasing departments looking for a traceable spare part of proven quality at a very competitive cost compared to the official replacement, without sacrificing the reliability required for patient monitoring in ICU, emergency department, operating theatre, hospital ward and in-hospital transport.
2. Technical explanation: how this battery works
The Spacelabs Medical Qube 91390 is a compact multiparameter vital signs monitor that records ECG, oxygen saturation (SpO2), non-invasive blood pressure (NIBP) and temperature, with a touchscreen and configuration for bedside, transport and perioperative settings. To ensure monitoring when the device is disconnected from the mains, during transfers or in case of a power cut, the monitor incorporates an internal rechargeable battery that acts as a backup power source.
It is a smart Li-ion battery with SMBus communication: while the monitor remains plugged in, the battery recharges automatically and the device’s electronics monitor the charge state and temperature; when disconnected or in the event of a power interruption, the battery seamlessly takes over powering the display, monitoring electronics, measurement modules and alarms, without interrupting patient monitoring. Li-ion chemistry offers high energy density, virtually no memory effect and low self-discharge, with internal protection against overcharge, overdischarge and short circuit.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888909 |
| Original manufacturer reference | 146-0142-00 |
| Other documented part numbers for the same pack | 146-0142-02, GPDR204, NI2040, SM204 (and variants NI2040A22, NI2040A24, NI2040HD24, NI2040-SL24, NI2040-SL29) |
| Application | Spacelabs Medical Qube vital signs monitor (model 91390) |
| Technology | Lithium-ion (Li-ion), rechargeable, with SMBus communication (smart battery) |
| Nominal voltage | 11.1 V |
| Capacity | 7.8 Ah (7,800 mAh) |
| Energy | 86.58 Wh |
| Weight | Approximately 0.6 kg (according to commercial datasheet) |
| Dimensions | 130 x 80 x 55 mm (according to commercial datasheet) |
| Rechargeable | Yes; automatic recharging with the monitor connected to the mains |
| GUDID (FDA) registration | Not found in AccessGUDID for code 146-0142-00 |
| Presentation | 1 unit |
| Device manufacturer | Spacelabs Medical |
Note: the dimensions and weight indicated correspond to those stated in the commercial datasheet. In specialised distribution catalogues, this pack is consistently documented with approximate dimensions of 213.11 x 58.51 x 22.22 mm and a weight of around 615 g (reference 146-0142-00/02). As this is a spare part, it is recommended to check dimensions, connector and cell configuration against the original battery before replacement.
4. Equivalences and Cross-References
The reference 146-0142-00 corresponds to the Li-ion battery that Spacelabs Medical installs in the Qube 91390 monitor, and it is consistently verified in specialised distribution catalogues, as well as on the manufacturer’s own website, which markets the current revision of the same pack under the code 146-0142-03 (NI2040SL29). The numbers 146-0142-02, GPDR204, NI2040 and SM204 are repeatedly documented in cross-reference lists as the same pack. The code is not registered in the FDA GUDID database (query performed in AccessGUDID).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Spacelabs Medical (equipment manufacturer) | Qube 91390 battery – revision of the same pack | 146-0142-02 | Exact reference equivalence (same manufacturer) | Revision of the same Li-ion battery for Qube 91390; cited alongside 146-0142-00 in distribution and spare parts cross-reference lists. Verify the code printed on the label of the installed battery. |
| Spacelabs Medical (equipment manufacturer) | Service part numbers for the same battery | GPDR204, NI2040, SM204 | Exact reference equivalence (same manufacturer) | Alternative part numbers for pack 146-0142-00/02 consistently documented in specialised distribution (including variants NI2040A22, NI2040A24, NI2040HD24 and NI2040-SL24). Same application and specification window. |
| Spacelabs Healthcare (current official spare part) | Official Qube 91390 battery (higher capacity) | 146-0142-03 (NI2040SL29) | Exact reference equivalence (same manufacturer) | Official Li-ion battery 10.8 V / 8.4 Ah (91 Wh) published on the manufacturer’s website as a spare part for Qube 91390. Declared voltage (10.8 V vs 11.1 V) and higher capacity: check the equipment’s charging electronics before replacing. |
| Cameron Sino | Medical series for patient monitor | CS-AMS272MD / MED-CS-AMS272MD | Comparable by category (not interchangeable 1:1) | Li-ion 11.1 V / 7,800 mAh (86.58 Wh), consistently documented as a replacement for 146-0142-00, 146-0142-02, GPDR204, NI2040 and SM204 for Qube 91390; declared dimensions ≈213.11 x 58.51 x 22.22 mm and ≈615 g. Same chemistry, voltage and capacity; check connector and housing against the mounted part. |
| R&D Batteries | OEM series (vital signs monitors) | 6487 / 6487-A | Comparable by category (not interchangeable 1:1) | Documented as an OEM battery for Spacelabs 91390 Qube Compact Monitor (146-0142-02); the manufacturer’s data sheet declares 10.8 V / 7.8 Ah (87 Wh) and cites the cross-references Cables and Sensors 11431 and NCE N1443-OEM. Declared voltage different (10.8 V vs 11.1 V): check dimension and connector before replacing. |
There is no equivalence table validated by Spacelabs Medical that authorises third-party batteries for reference 146-0142-00; the alternatives from other manufacturers listed are comparable by category and must be verified against the technical data sheet and the equipment manual before use. It is recommended to consult the technical department before using this reference in tenders.
5. Selection tips and variants of interest
- Identify the exact monitor: this 11.1 V / 7.8 Ah battery is the one indicated for the Spacelabs Medical Qube family (model 91390). Do not confuse it with batteries from other monitors of the same brand with different voltage, chemistry or capacity (e.g. the 10.8 V / 6.6 Ah for mCare 300, ref. 88888305, or the 12 V for UltraView).
- Check the reference of the installed battery: check on the battery label the codes 146-0142-00, 146-0142-02, GPDR204, NI2040 or SM204 before replacing. Always respect the voltage (11.1 V) and the Li-ion chemistry; do not use batteries of other chemistry or voltage without validation from the technical service.
- Replace upon signs of wear: clearly reduced battery life or low battery warnings a few hours after charging indicate that the battery has reached the end of its useful life.
- After replacement: leave the monitor connected to the mains to complete the charge and verify that the battery indicator reflects the new status before returning the equipment to clinical service.
- Orders by reference: always indicate the Cahnos code 88888909 or the original equipment reference (146-0142-00) to avoid confusion with other batteries in the Spacelabs family.
- Waste management: deliver the depleted lithium battery to an authorised collection point in accordance with WEEE regulations; do not dispose of it in the general waste container.
- Mixed fleets: consult our catalogue of batteries for vital signs monitors; we have spare parts for the Spacelabs, Philips, GE HealthCare, Mindray, Nihon Kohden and other families. If in any doubt, contact our technical-commercial department indicating model, serial number and reference of the installed battery.