We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Li-ion battery 11.1V 7.8Ah (86.58Wh) for Spacelabs Medical Qube 91390 Vital Signs Monitor | Original ref. 146-0142-00 | Replacement ref. 88888909

368,00 €

Replacement Li-ion battery 11.1 V and 7.8 Ah (86.58 Wh) for the Spacelabs Medical Qube vital signs monitor (model 91390), corresponding to the original reference 146-0142-00 (same package documented as 146-0142-02, GPDR204, NI2040 and SM204). Rechargeable battery with SMBus communication and integrated recharging in the equipment that maintains monitoring of ECG, SpO2, pressure and temperature during transfers, power cuts or continuous operation. Traceable spare part ready to install, indicated for medical electronics services, ICU, emergency and hospitalisation; check the code printed on the installed battery before ordering. Ref. Cahnos 88888909, price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888909

Description

1. Reliable power for your Spacelabs Medical Qube monitor

At Cahnos we offer the spare battery for the Spacelabs Medical Qube (model 91390) vital signs monitor, reference Cahnos 88888909, corresponding to the original manufacturer reference 146-0142-00. This is a rechargeable lithium-ion (Li-ion) battery of 11.1 V and 7.8 Ah (86.58 Wh) that restores full autonomy to the device for continuous patient monitoring when the monitor is not connected to the mains power supply.

It is the ideal solution for biomedical engineering services, medical electronics maintenance and hospital purchasing departments looking for a traceable spare part of proven quality at a very competitive cost compared to the official replacement, without sacrificing the reliability required for patient monitoring in ICU, emergency department, operating theatre, hospital ward and in-hospital transport.

2. Technical explanation: how this battery works

The Spacelabs Medical Qube 91390 is a compact multiparameter vital signs monitor that records ECG, oxygen saturation (SpO2), non-invasive blood pressure (NIBP) and temperature, with a touchscreen and configuration for bedside, transport and perioperative settings. To ensure monitoring when the device is disconnected from the mains, during transfers or in case of a power cut, the monitor incorporates an internal rechargeable battery that acts as a backup power source.

It is a smart Li-ion battery with SMBus communication: while the monitor remains plugged in, the battery recharges automatically and the device’s electronics monitor the charge state and temperature; when disconnected or in the event of a power interruption, the battery seamlessly takes over powering the display, monitoring electronics, measurement modules and alarms, without interrupting patient monitoring. Li-ion chemistry offers high energy density, virtually no memory effect and low self-discharge, with internal protection against overcharge, overdischarge and short circuit.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) 88888909
Original manufacturer reference 146-0142-00
Other documented part numbers for the same pack 146-0142-02, GPDR204, NI2040, SM204 (and variants NI2040A22, NI2040A24, NI2040HD24, NI2040-SL24, NI2040-SL29)
Application Spacelabs Medical Qube vital signs monitor (model 91390)
Technology Lithium-ion (Li-ion), rechargeable, with SMBus communication (smart battery)
Nominal voltage 11.1 V
Capacity 7.8 Ah (7,800 mAh)
Energy 86.58 Wh
Weight Approximately 0.6 kg (according to commercial datasheet)
Dimensions 130 x 80 x 55 mm (according to commercial datasheet)
Rechargeable Yes; automatic recharging with the monitor connected to the mains
GUDID (FDA) registration Not found in AccessGUDID for code 146-0142-00
Presentation 1 unit
Device manufacturer Spacelabs Medical

Note: the dimensions and weight indicated correspond to those stated in the commercial datasheet. In specialised distribution catalogues, this pack is consistently documented with approximate dimensions of 213.11 x 58.51 x 22.22 mm and a weight of around 615 g (reference 146-0142-00/02). As this is a spare part, it is recommended to check dimensions, connector and cell configuration against the original battery before replacement.

4. Equivalences and Cross-References

The reference 146-0142-00 corresponds to the Li-ion battery that Spacelabs Medical installs in the Qube 91390 monitor, and it is consistently verified in specialised distribution catalogues, as well as on the manufacturer’s own website, which markets the current revision of the same pack under the code 146-0142-03 (NI2040SL29). The numbers 146-0142-02, GPDR204, NI2040 and SM204 are repeatedly documented in cross-reference lists as the same pack. The code is not registered in the FDA GUDID database (query performed in AccessGUDID).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Spacelabs Medical (equipment manufacturer) Qube 91390 battery – revision of the same pack 146-0142-02 Exact reference equivalence (same manufacturer) Revision of the same Li-ion battery for Qube 91390; cited alongside 146-0142-00 in distribution and spare parts cross-reference lists. Verify the code printed on the label of the installed battery.
Spacelabs Medical (equipment manufacturer) Service part numbers for the same battery GPDR204, NI2040, SM204 Exact reference equivalence (same manufacturer) Alternative part numbers for pack 146-0142-00/02 consistently documented in specialised distribution (including variants NI2040A22, NI2040A24, NI2040HD24 and NI2040-SL24). Same application and specification window.
Spacelabs Healthcare (current official spare part) Official Qube 91390 battery (higher capacity) 146-0142-03 (NI2040SL29) Exact reference equivalence (same manufacturer) Official Li-ion battery 10.8 V / 8.4 Ah (91 Wh) published on the manufacturer’s website as a spare part for Qube 91390. Declared voltage (10.8 V vs 11.1 V) and higher capacity: check the equipment’s charging electronics before replacing.
Cameron Sino Medical series for patient monitor CS-AMS272MD / MED-CS-AMS272MD Comparable by category (not interchangeable 1:1) Li-ion 11.1 V / 7,800 mAh (86.58 Wh), consistently documented as a replacement for 146-0142-00, 146-0142-02, GPDR204, NI2040 and SM204 for Qube 91390; declared dimensions ≈213.11 x 58.51 x 22.22 mm and ≈615 g. Same chemistry, voltage and capacity; check connector and housing against the mounted part.
R&D Batteries OEM series (vital signs monitors) 6487 / 6487-A Comparable by category (not interchangeable 1:1) Documented as an OEM battery for Spacelabs 91390 Qube Compact Monitor (146-0142-02); the manufacturer’s data sheet declares 10.8 V / 7.8 Ah (87 Wh) and cites the cross-references Cables and Sensors 11431 and NCE N1443-OEM. Declared voltage different (10.8 V vs 11.1 V): check dimension and connector before replacing.

There is no equivalence table validated by Spacelabs Medical that authorises third-party batteries for reference 146-0142-00; the alternatives from other manufacturers listed are comparable by category and must be verified against the technical data sheet and the equipment manual before use. It is recommended to consult the technical department before using this reference in tenders.

5. Selection tips and variants of interest

  • Identify the exact monitor: this 11.1 V / 7.8 Ah battery is the one indicated for the Spacelabs Medical Qube family (model 91390). Do not confuse it with batteries from other monitors of the same brand with different voltage, chemistry or capacity (e.g. the 10.8 V / 6.6 Ah for mCare 300, ref. 88888305, or the 12 V for UltraView).
  • Check the reference of the installed battery: check on the battery label the codes 146-0142-00, 146-0142-02, GPDR204, NI2040 or SM204 before replacing. Always respect the voltage (11.1 V) and the Li-ion chemistry; do not use batteries of other chemistry or voltage without validation from the technical service.
  • Replace upon signs of wear: clearly reduced battery life or low battery warnings a few hours after charging indicate that the battery has reached the end of its useful life.
  • After replacement: leave the monitor connected to the mains to complete the charge and verify that the battery indicator reflects the new status before returning the equipment to clinical service.
  • Orders by reference: always indicate the Cahnos code 88888909 or the original equipment reference (146-0142-00) to avoid confusion with other batteries in the Spacelabs family.
  • Waste management: deliver the depleted lithium battery to an authorised collection point in accordance with WEEE regulations; do not dispose of it in the general waste container.
  • Mixed fleets: consult our catalogue of batteries for vital signs monitors; we have spare parts for the Spacelabs, Philips, GE HealthCare, Mindray, Nihon Kohden and other families. If in any doubt, contact our technical-commercial department indicating model, serial number and reference of the installed battery.

Additional information

Accumulator type

Lithium-ion (Li-ion), rechargeable, with SMBus communication (smart battery)

Manufacturer reference

146-0142-00 (also documented as 146-0142-02, GPDR204, NI2040, SM204)

Nominal voltage

11.1 V

Capacity

7.8 Ah (7,800 mAh)

Energy

86.58 Wh

Compatibility

Spacelabs Medical Qube vital signs monitor (model 91390)

Dimensions

130 x 80 x 55 mm (commercial datasheet); approx. 213.11 x 58.51 x 22.22 mm according to specialised distribution (check against assembled part)

Weight

approx. 0.6 kg (approx. 615 g according to specialised distribution)

Rechargeable

Yes; automatic recharging with the monitor connected to the mains

Device manufacturer

Spacelabs Medical

Application

ICU, emergency department, operating theatre, hospital ward and in-hospital transport

Chemistry

Memory-effect-free Li-ion

Communication

SMBus (smart battery)

GUDID registration

Not found in AccessGUDID (FDA)

Installation

Direct replacement in the equipment compartment

Maintenance

Maintenance-free; periodic inspection in medical electronics

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Li-ion battery 11.1V 7.8Ah (86.58Wh) for Spacelabs Medical Qube 91390 Vital Signs Monitor | Original ref. 146-0142-00 | Replacement ref. 88888909”

Your email address will not be published. Required fields are marked *