Description
1. Commercial Introduction
Keeping a vital signs monitor operational is a daily requirement in hospitals, health centres and critical care units. With the Philips IntelliVue MX40 rechargeable battery (ref. Cahnos 88888844), medical electronics and maintenance services have the appropriate lithium-ion spare for the battery compartment of the portable telemetry monitor, ensuring that patient monitoring —ECG, SpO₂ and other parameters— is not interrupted during intra-hospital transfers, ambulance transport or a power supply failure.
It is the reliable and proven solution your fleet of Philips IntelliVue MX40 monitors needs, with the warranty and technical-commercial advice from Cahnos for scheduled replacement, institutional purchases and medical electronics tenders.
2. Technical explanation of the equipment and the battery
The Philips IntelliVue MX40 monitor is a portable and wearable telemetry monitor designed for continuous patient monitoring while on the move. The device can operate on AA batteries or its internal rechargeable lithium-ion battery: while the monitor is in its docking station or connected to the mains, the accumulator is automatically kept charged; when disconnected or during a transfer, the battery takes over the power supply without interrupting monitoring or data recording.
Li-ion chemistry offers high energy density, stable voltage of 3.7 V, virtually no memory effect and a compact profile that fits into the rear compartment of the MX40. A degraded cell manifests itself with loss of autonomy or premature low-battery warnings; preventive replacement with this reference restores the device to its original performance in a few minutes and without tools.
Technical note on the reference: the datasheet cites the transcription “MFR 04605A”, but the official code that Philips assigns to the MX40 monitor battery is 989803176201 (pack of 1 unit) and 989803174131 (pack of 3 units), with the 2024 revision 989803205801 / 989803205811 and the internal P/N 453564413441. The numbering “04605A” also coincides with the transcription of the M4605A pack from the IntelliVue MP platform (10.8 V / 6 Ah), a different and non-interchangeable battery. Always verify the code and chemistry printed on the removed pack before replacement.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88888844 |
| Application | Philips IntelliVue MX40 vital signs monitors (Philips equipment 865350 / 865351) |
| Original reference cited | 04605A (distributor transcription; official Philips code: 989803176201 / 989803174131 / 989803205801 / 989803205811, P/N 453564413441) |
| Technology | Li-ion (lithium-ion), rechargeable |
| Nominal voltage | 3.7 V |
| Capacity | 1.9 Ah (1,900 mAh) |
| Energy | 7.03 Wh (≈7 Wh according to official Philips datasheet) |
| Dimensions | 63 x 45 x 20 mm |
| Weight | Approximately 0.1 kg |
| Device manufacturer | Philips |
| Reusable | Yes (reusable product, multi-patient use, according to official Philips datasheet) |
| Recharge | Automatic, integrated into the station or the monitor when connected |
| Installation | Direct replacement in the equipment compartment, without tools |
| Maintenance | Maintenance-free |
| Shelf life | Philips declares “Life Time 180” in its official datasheet; shelf life of 3 months |
| Presentation | 1 unit |
| Origin | Made in China |
| Recycling | Do not dispose of as municipal waste; recycle in accordance with RAEE / WEEE regulations |
4. Equivalences and Cross-References
The official factory reference for the Li-ion pack of the Philips IntelliVue MX40 monitor is 989803176201 (1 unit) / 989803174131 (3 units), internally coded as 453564413441 and revised in 2024 with the numbers 989803205801 / 989803205811, consistently confirmed on the official Philips website and in specialised distribution. Philips does not publish an official equivalence table authorising third-party batteries; the listed alternatives share chemistry (Li-ion) and voltage (3.7 V), but come from another manufacturer and are classified as comparable by category, not 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Philips (equipment manufacturer) | Rechargeable 3.7 V battery for IntelliVue MX40 (pack of 1 unit) | 989803176201 | Exact reference equivalence (same manufacturer) | Official reference confirmed on the Philips website (HC989803176201): Li-ion, 3.7 V, 1,900 mAh, rechargeable. This is the reference that this datasheet reproduces under the transcription “MFR 04605A”. |
| Philips (equipment manufacturer) | Rechargeable 3.7 V battery for IntelliVue MX40 (pack of 3 units) | 989803174131 | Exact reference equivalence (same manufacturer) | Same battery in a 3-unit presentation, confirmed on the official Philips website (HC989803174131). |
| Philips (equipment manufacturer) | 2024 revision of the MX40 pack (1 unit) | 989803205801 (replaces 989803176201) | Comparable by category (not interchangeable 1:1) | Updated revision of the pack documented on the official Philips website and in specialised distribution with 3.7 V / 2.0 Ah; verify compatibility and mechanics with the monitor before replacing. |
| Axcom | Replacement battery for Philips IntelliVue MX40 | MBMX40 | Comparable by category (not interchangeable 1:1) | Li-ion 3.7 V / 1.9 Ah; replaces 989803176201 / 989803174131 according to the replacement manufacturer’s datasheet and is compatible with Philips equipment 865350 / 865351; it is not an original part, verify connector and housing. |
| R&D Batteries | Battery for Philips Intellivue MX40 (989803176201) | 6440 | Comparable by category (not interchangeable 1:1) | Li-ion 3.7 V / 1.9 Ah / 7 Wh documented in the replacement manufacturer’s catalogue; includes cross-references Anybattery 8723 and OSI B12077; verify compartment mechanics. |
| OSI Batteries | Replacement battery for Philips Intellivue MX40 (1 unit) | B12077 | Comparable by category (not interchangeable 1:1) | Li-ion 3.7 V / 2.0 Ah; replaces OEM 989803205801 according to the replacement manufacturer’s catalogue; it is not an original Philips part. |
There is no equivalence table validated by the manufacturer (Philips) cross-referencing the 04605A reference with third-party batteries; consult the technical department before use in a tender. Before any replacement, the following must be verified one by one: voltage (3.7 V), chemistry (Li-ion), connector and compartment dimensions.
5. Selection tips and variants of interest
- Confirm the exact monitor: this battery is for the Philips IntelliVue MX40 portable telemetry monitor (equipment 865350 / 865351). Verify the code printed on the removed battery (989803176201 / 989803174131 / 989803205801 / 453564413441) before ordering.
- Do not confuse Philips families: the transcription “04605A” matches the M4605A pack for the IntelliVue MP platform (10.8 V / 6 Ah), a different and non-interchangeable battery even though it is also for a Philips monitor. The MP2/X2 uses the M4607A and the Viridia platform uses the M3046A.
- Replace when signs of wear appear: clearly reduced battery life or low-battery warnings a few hours after charging indicate the end of the accumulator’s useful life. After installation, allow a full charge cycle to complete before a prolonged session in portable mode.
- Storage and recycling: keep the battery in a cool, dry place if it is not going to be used, and recharge it periodically to prevent degradation of the Li-ion chemistry. Take the exhausted pack to a collection point in accordance with WEEE regulations; never dispose of it in the general waste container.
- Institutional purchasing: for tenders, bids or ongoing supply contracts, contact our technical-commercial department stating the model, serial number and reference of the installed accumulator; we will confirm compatibility and offer special conditions for volume.





Reviews