Ni-Cd Battery 19.2V 1.8Ah for Electrocardiograph GE Healthcare MAC PC / MAC 6 | Replaces Ref. 3807-001 | Ref. 88888221

130,00 €

Rechargeable nickel-cadmium (Ni-Cd) battery, 19.2 V and 1.8 Ah for the GE Healthcare MAC PC electrocardiograph (Marquette / Hellige family), also compatible with the MAC 6 recorder. Replaces the original equipment reference 3807-001 and restores the device’s full battery life for continuous diagnostic sessions in the clinic, hospitalisation and intra-hospital transport. High-quality replacement, with Cs format cells, direct installation in the battery compartment and automatic recharging while the equipment remains connected to the mains. Ref. Cahnos 88888221.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88888221

Description

1. Commercial Introduction

Keeping the electrocardiograph always operational is essential in any cardiology department, and the internal battery is the component that ensures diagnostic continuity when the device is not connected to the mains. With this rechargeable nickel-cadmium (Ni-Cd) battery of 19.2 V and 1.8 Ah for the GE Healthcare MAC PC (Ref. Cahnos 88888221), your department will have a reliable, high-quality replacement ready to install, suitable for hospitals, clinics, cardiology outpatient departments, emergency services and medical electronics maintenance contracts.

It is the practical solution for keeping your fleet of MAC PC family electrocardiographs operational during patient transfers, power cuts or off-grid operation, with automatic recharging while the device remains plugged in. The code 88888221 is the reference under which this replacement is supplied in the authorised distribution network, replacing the original equipment reference GE/Marquette 3807-001.

2. Technical explanation of the equipment and the battery

The GE Healthcare MAC PC electrocardiograph (manufactured by the Marquette family, later integrated into GE Healthcare, with Hellige/Marquette origins) is a 12-lead electrocardiographic recording and interpretation device used in cardiology outpatient departments, emergency departments and hospitalisation. To ensure operability when the device is disconnected from the mains, it incorporates an internal rechargeable battery that acts as a portable power source: while the electrocardiograph is connected to the mains, the accumulator remains on charge; if the supply fails or the device is moved, the battery automatically takes over the power supply without interrupting the examination.

This replacement is a rechargeable pack with nickel-cadmium (Ni-Cd) chemistry that delivers a nominal voltage of 19.2 V and a capacity of 1.8 Ah (approximately 34.6 Wh), made up of Cs-format (sub-C) cells. Ni-Cd chemistry is a mature and robust technology, suitable for frequent charge and discharge cycles in healthcare environments, with good current delivery and tolerance to deep discharges. It is housed in the device’s battery compartment and is replaced directly, without tools or adaptations. Before replacing, confirm the reference 3807-001 on the original battery label and the exact device model (MAC PC or MAC 6).

3. Technical Specifications

Data cross-checked with the distribution technical data sheet for the replacement (same SKU 88888221) and with the specifications of the original equipment reference.

Parameter Specification
Product type Rechargeable internal battery for electrocardiograph
Reference Cahnos (SKU) 88888221
Original equipment reference it replaces 3807-001 (GE Healthcare / Marquette)
Technology / Chemistry Ni-Cd (nickel-cadmium), rechargeable
Nominal voltage 19.2 V
Nominal capacity 1.8 Ah (1,800 mAh)
Approximate energy 34.6 Wh (19.2 V × 1.8 Ah)
Cell format Cs (sub-C); Saft-type cells according to distribution data sheet
Approximate weight 0.752 kg
Recharge Automatic with the electrocardiograph connected to the mains supply
Installation Direct replacement in the equipment battery compartment, without tools
Compatible devices GE Healthcare MAC PC and MAC 6 (Marquette / Hellige family); also documented for MAC 12 in distribution
Intended use Cardiology outpatient departments, emergency departments, hospitalisation, intra-hospital transport and medical electronics maintenance
Presentation 1 unit

4. Equivalences and Cross-References

The reference 3807-001 is the code for the original battery of the GE/Marquette MAC PC and MAC 6 and is consistently documented in authorised and specialised spare parts distribution as a 19.2 V, 1.6 Ah Ni-Cd rechargeable battery for these electrocardiographic recorders (also referenced as B10412 in aftermarket listings for the same battery). GE Healthcare does not publish an official cross-reference table with third-party batteries; the references listed below share chemistry (Ni-Cd) and voltage (19.2 V) with this replacement, but must be validated field by field (actual capacity, connector, dimensions and terminal orientation) before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GE Healthcare / Marquette (equipment manufacturer) Original MAC PC / MAC 6 battery (19.2 V Ni-Cd) 3807-001 Comparable by category (not interchangeable 1:1) Original electrocardiograph reference replaced by this replacement; same Ni-Cd chemistry and 19.2 V voltage, documented capacity of 1.6 Ah (this replacement: 1.8 Ah). Verify connector, dimensions and terminal orientation of the device. Consistently confirmed in multiple independent distribution sources.
Carley Lamps Replacement battery for Marquette Electronics 3807-001 CL50015 Comparable by category (not interchangeable 1:1) Ni-Cd 19.2 V / 1.6 Ah with wiring and connector; replaces the 3807-001. Lower capacity (1.6 vs 1.8 Ah) and aftermarket construction; verify connector and fit in the compartment before replacing. Confirmed in the battery manufacturer’s data sheet.
Standardised aftermarket (BatteryTex / Davis Medical / RD Batteries) Replacement battery for Mac PC, Mac 6 (3807-001) 5125 Comparable by category (not interchangeable 1:1) Widely used aftermarket code for this battery, documented as Ni-Cd 19.2 V / 1.6 Ah for MAC PC and MAC 6. Third-party capacity and construction; validate connector and dimensions against the specific equipment.
Beck-Lee Generic replacement battery for MAC PC, MAC 6, MAC 12 MNC38071L Comparable by category (not interchangeable 1:1) Ni-Cd 19.2 V / 1.5 Ah documented for MAC PC, MAC 6 and MAC 12. Capacity lower than that of this replacement; verify connector and fit before replacing. Authorised distributor code, cited for reference only.

There is no equivalence table validated by the equipment manufacturer (GE Healthcare) that cross-references this part with third-party batteries; the references indicated have been verified against manufacturer and specialised distribution catalogues, but 1:1 replacement must be validated field by field (voltage, chemistry, capacity, pack dimensions and connector) against the specific equipment. Consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Verify the exact model of the equipment: this 19.2 V / 1.8 Ah battery is the one indicated for the GE Healthcare MAC PC electrocardiograph and the MAC 6 recorder (also documented for MAC 12 in distribution). Do not install it in other models of the MAC family that use different batteries, such as the MAC 5000 (18 V / 3.5 Ah Ni-MH, ref. 900770-001, available at Cahnos as 88888228) or the Cardiosmart MAC 1200 (18 V / 1.8 Ah, refs. 88888210 / 88888911); always check the label on the equipment and the original battery.
  • Confirm the stamped reference: if the removed battery shows the code 3807-001 (or its variant B10412), it may be the original battery that this replacement substitutes; contact our technical-commercial department to confirm before placing the order.
  • Replace upon signs of wear: clearly reduced battery life, premature low-battery warnings or excessive charging times indicate that the Ni-Cd battery has reached the end of its useful life.
  • Maintenance of Ni-Cd chemistry: perform periodic full cycles and avoid leaving the electrocardiograph for a long time with the battery completely discharged; this extends the useful life of the pack. Comply with nickel-cadmium battery recycling regulations.
  • After replacement: leave the equipment connected to the mains to complete the charge and verify that the battery indicator reflects the new state before returning it to service.
  • Purchases for fleets and tenders: for electrocardiograph fleets, maintenance contracts or public tenders, request special conditions, availability and documentation (declaration of conformity and safety data sheet) from our technical-commercial team.

Additional information

Product type

Rechargeable internal battery for electrocardiograph

Manufacturer reference

3807-001 (Marquette / GE Healthcare); alternative part numbers B10412 and AS10412

Chemistry

Ni-Cd (nickel-cadmium), rechargeable

Nominal voltage

19.2 V

Nominal capacity

1.8 Ah (1,800 mAh)

Pack configuration

Cs-format cells in series

Dimensions

160 x 90 x 23 mm

Weight

0.75 – 0.80 kg

Rechargeable

Yes (automatic recharging with the device connected to the mains)

Compatibility

GE Healthcare MAC PC and MAC 6 (Marquette / Hellige family); also documented for MAC 12 in distribution

Application

12-lead ECG recording and interpretation in cardiology, emergency and outpatient departments

Original equipment reference

3807-001 (GE Healthcare / Marquette)

Approximate energy

34.6 Wh

Cell format

Cs (sub-C); Saft-type cells according to distribution data sheet

Approximate weight

0.752 kg

Recharge

Automatic with the electrocardiograph connected to the mains supply

Installation

Direct replacement in the battery compartment, without tools

Use

Cardiology outpatient departments, emergency departments, hospitalisation and medical electronics maintenance

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Ni-Cd Battery 19.2V 1.8Ah for Electrocardiograph GE Healthcare MAC PC / MAC 6 | Replaces Ref. 3807-001 | Ref. 88888221”