Description
1. Commercial Introduction
At Cahnos we offer you the replacement lithium-ion battery of 10.8 V and 3.8 Ah (41 Wh) for the vital signs monitor GE HealthCare Carescape B450, Ref. Cahnos 88881157. This battery reproduces the specifications of the original GE factory part (ref. 2062895-001, model FLEX-3S2P) and restores the equipment’s full autonomy when it is disconnected from the mains: internal transfers, intra-hospital transport, mobile units and power cuts. Available with fast delivery for intensive care, anaesthesia, operating theatre, emergency, hospitalisation services, medical electronics companies and monitoring equipment maintenance contracts. Price per unit.
2. Technical explanation of the equipment and the battery
The GE HealthCare CARESCAPE B450 monitor is a flexible acuity patient monitoring system (ECG, saturation, non-invasive pressure, temperature and other parameters) designed to maintain continuity of clinical data both at the bedside and during transport. To guarantee uninterrupted monitoring when the equipment is disconnected from the mains or moved, it incorporates an internal rechargeable battery that acts as a backup source: while the monitor remains connected to the power supply, the battery stays charged; if the supply fails or the patient is transferred, the battery automatically takes over the power supply without interrupting monitoring.
This replacement is a pack of 6 18650 cells in 3S2P configuration (3 in series × 2 in parallel) with lithium-ion chemistry, nominal voltage of 10.8 V and capacity of 3.8 Ah (≈41 Wh). As documented in the official GE HealthCare data sheet (GE HealthCare Service Shop, art. 2062895-001), it incorporates SMBUS communication interface, integrated charge level indication window and visibility LED, and operates in a temperature range of -20 °C to 60 °C. Li-ion chemistry offers high energy density, low self-discharge, no memory effect and a longer cycle life than nickel technologies. Replacement is carried out directly in the equipment compartment, without tools or adaptations.
3. Technical Specifications
Data cross-checked against the official data sheet for GE part 2062895-001 published on GE HealthCare Service Shop and against battery manufacturer data sheets and authorised technical distribution for third-party cross-references.
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88881157 |
| Manufacturer reference (GE HealthCare) | 2062895-001 (Battery FLEX-3S2P 10.8V 18650 Li-Ion SMBUS) |
| Other part numbers for the same battery | FLEX-3S2P, 101818-42336, U80296-1R01, 02379, 3ICR19/66-2 |
| Battery type | Rechargeable lithium-ion (Li-Ion) battery pack |
| Nominal voltage | 10.8 V |
| Nominal capacity | 3.8 Ah (3,800 mAh) |
| Energy | ≈41 Wh (41.04 Wh) |
| Cell configuration | 6 18650 cells, 3S2P configuration |
| Interface / management | SMBUS; charge level window and illuminated LED indicator |
| Operating temperature (official GE datasheet) | -20 °C to 60 °C |
| Approximate dimensions (distribution) | 152.1 x 59.2 x 21.6 mm |
| Approximate weight (distribution) | ≈320 g |
| Compatibility | GE HealthCare CARESCAPE B450 vital signs monitor |
| Recharge | Automatic with the monitor connected to the mains |
| Compliance declared by GE HealthCare | UL-1642, UL-2054, UN-3480, GB-31241-2014, IS-16046-2015, IEC 62133, IEC 61000-4-2; lead-free; RoHS and REACH |
| Installation | Direct replacement in the monitor compartment, without tools |
| Intended use | Hospital, ICU, operating theatre, anaesthesia, emergency, mobile units and intra-hospital transport |
| Presentation | 1 unit |
Compatibility note: confirm the exact model of your equipment (CARESCAPE B450) and the reference printed on the removed battery before replacing. Batteries for the B650/B105/B125 (ref. 2036984-001) are not interchangeable with this battery.
4. Equivalences and Cross-References
Reference 2062895-001 is confirmed in the official GE HealthCare parts catalogue (GE HealthCare Service Shop) as a rechargeable Li-Ion battery of 10.8 V / 3.8 Ah with SMBUS interface for the CARESCAPE B450 monitor, under the model designation FLEX-3S2P. GE HealthCare does not publish an official cross-reference table with third-party batteries; the alternatives indicated have been cross-checked against battery manufacturer data sheets and authorised technical distribution, share chemistry, voltage, capacity and pack format (6 18650 cells, 3S2P) and are considered comparable at category level, not 1:1 interchangeable. Before replacing, validation must be carried out field by field (voltage, capacity, dimensions, connector and SMBUS protocol).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GE HealthCare (part numbers for the same accumulator) | FLEX-3S2P battery for the CARESCAPE B450 monitor (Li-Ion 10.8 V / 3.8 Ah) | FLEX-3S2P, 101818-42336, U80296-1R01, 02379, 3ICR19/66-2 | Comparable by category (not interchangeable 1:1) | Part numbers of the same original piece documented in GE HealthCare Service Shop and in authorised distribution listings; identical chemistry, voltage and capacity. Confirm the equipment’s batch label before ordering. |
| Cameron Sino | Replacement battery for GE Carescape B450 Monitor | CS-GMB450MD | Comparable by category (not interchangeable 1:1) | Li-Ion 10.8 V / 3,800 mAh (41.04 Wh), dimensions 152.10 x 59.20 x 21.60 mm, replaces FLEX-3S2P, 2062895-001, 3ICR19/66-2 and 02379; verified in manufacturer data sheet and authorised distribution. Validate SMBUS, connector and compartment fit. |
| Kingsener | FLEX-3S2P battery for GE Healthcare Monitor B450 | FLEX-3S2P (Kingsener listing) | Comparable by category (not interchangeable 1:1) | Li-Ion 10.8 V / 3.80 Ah (41 Wh), 6 18650 cells, replaces FLEX-3S2P, 101818-42336, U80296-1R01 and 2062895-001; third-party construction with 1-year warranty. Confirm chemistry, connector and SMBUS protocol before replacing. |
| R&D Batteries | OEM replacement battery for GE Carescape B450 FLEX-3S2P | 6541 | Comparable by category (not interchangeable 1:1) | 10.8 V / 3.8 Ah Li-Ion documented as a replacement for the 2062895-001 (source, with Cameron Sino CS-GMB450MD cross-reference); same chemistry, voltage and nominal capacity. Verify connector, dimensions and fixing in the compartment. |
There is no equivalence table validated by the manufacturer (GE HealthCare) that cross-references this reference with third-party batteries; consult the technical department before using it in a tender.
5. Selection tips and variants of interest
- Identify the monitor: this battery corresponds to the GE HealthCare CARESCAPE B450 monitor. If your device is from another series (CARESCAPE B650, B105, B125, Dash, etc.), it is not interchangeable with this reference; the B650 / B105 / B125 uses battery ref. 2036984-001.
- Check the label: confirm the engraved reference (2062895-001, FLEX-3S2P, 101818-42336, U80296-1R01 or another) as well as voltage (10.8 V), capacity (3.8 Ah) and Li-Ion chemistry before replacing. Do not use accumulators of a different voltage even if the connector looks similar.
- Safe replacement: carry out the change with the monitor switched off; after assembly, leave the device connected to the mains to complete the charge and check that the battery indicator reflects the new status before returning it to service.
- Wear symptoms: clearly reduced battery life, premature low-battery warnings or excessive charging times indicate that the Li-Ion accumulator has reached the end of its useful life (typically 500-800 cycles depending on use).
- Other GE HealthCare family references in catalogue: we have spare parts for GE monitors, e.g. ref. 88888819 for CARESCAPE B650 (11.1 V / 6 Ah), ref. 88888214 for Dash 3000-4000 (11.1 V / 3.5 Ah), ref. 88881004 for Dash 2500 or ref. 88888116 for CardioCap 5. If you manage a mixed fleet, consult our catalogue of vital signs monitor batteries.
- Environmental management: deliver the exhausted battery to a specialised collection point (WEEE); do not place it in the general waste container.
- Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department stating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order.





Reviews