We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

GE HealthCare CardioCap 5 12V 2.6Ah sealed lead-acid (SLA) battery – Spare part MFR 17013 | Ref. 88888116

32,00 €

Replacement battery 12V 2.6Ah for GE HealthCare CardioCap 5 vital signs monitor, official factory reference MFR 17013 (Ref. Cahnos 88888116). Sealed lead-acid (SLA/VRLA) rechargeable technology, maintenance-free and with Faston 4.8 mm terminals, identical in chemistry, voltage and capacity to the one fitted as standard on the new equipment. Guarantees stable and continuous power backup in operating theatre, ICU, mobile units and intra-hospital transport, avoiding monitoring interruptions during transfers or power cuts. Verified against the official GE HealthCare catalogue (art. 17013).

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888116

Description

1. Replacement battery for CardioCap 5 monitor: reliable backup power

At Cahnos we offer you the replacement battery 12V 2.6Ah for the GE HealthCare CardioCap 5 vital signs monitor (Ref. Cahnos 88888116, factory reference MFR 17013). It is a sealed lead-acid (SLA/VRLA) rechargeable, maintenance-free accumulator, designed to keep patient monitoring running when the equipment is not connected to the mains: during internal transfers, in mobile units or in the event of a power cut.

Available with fast delivery for intensive care, anaesthesia, operating theatre, emergency, hospitalisation units, medical electronics companies and monitoring equipment maintenance contracts. Price per unit.

2. Technical explanation of the equipment and the battery

The GE HealthCare CardioCap 5 monitor is a patient monitoring system (ECG, saturation, non-invasive pressure, capnography and other parameters) commonly used in anaesthesia and intensive care. To ensure continuity of surveillance when the equipment is disconnected from the mains or during transport, it incorporates an internal rechargeable sealed lead battery of 12 V that acts as a backup source: while the monitor remains connected to the mains, the battery is kept on float charge; if the supply fails or the equipment is moved, the battery automatically takes over the power supply without interrupting monitoring.

The SLA/VRLA chemistry (valve-regulated, no free electrolyte) allows operation in any orientation, is maintenance-free and does not require water replenishment. According to the manufacturer’s official datasheet (GE HealthCare Service Shop, art. 17013), it is a rechargeable 12 V and 2.6 Ah battery with Faston tab 187 (4.8 mm) terminals, suitable for operation between -15 °C and 50 °C.

3. Technical Specifications

Data verified against the datasheet for article 17013 published by GE HealthCare Service Shop (equipment manufacturer).

Parameter Specification
Reference Cahnos (SKU) 88888116
Manufacturer reference (GE HealthCare) MFR 17013 (Battery 12V 2.6Ah Rechargeable Sealed Terminals)
Battery type Sealed lead-acid (SLA/VRLA), rechargeable, maintenance-free, leak-proof and spill-proof
Nominal voltage 12 V
Nominal capacity 2.6 Ah
Terminals Faston tab 187 (4.8 mm)
Compatibility GE HealthCare CardioCap 5 (CardioCap /5) and CardioCap monitors (patient monitoring range)
Operating temperature -15 °C to 50 °C
Recharge Automatic with the monitor connected to the mains; the equipment indicates the battery charge status
Compliance declared by GE HealthCare RoHS; JIS compliance; UL1778; UL94V-0 (flammability)
Intended use Hospital, ICU, operating theatre, anaesthesia, emergency, mobile units and intra-hospital transport
Presentation 1 unit

Compatibility note: confirm the exact model of your equipment (CardioCap 5 versus other series in the GE range) before replacing the battery, as well as the terminal orientation and the fixing in the original compartment.

4. Equivalences and Cross-References

The reference 17013 is confirmed in the official GE HealthCare parts catalogue (GE HealthCare Service Shop, US, UK and India editions) as a rechargeable sealed lead battery of 12 V / 2.6 Ah with Faston 4.8 mm terminals for the CardioCap 5 and CardioCap monitoring systems. In European distribution networks, the legacy code 897507 (associated with the Corometrics/Critikon/Marquette line of the brand) also circulates; this is data not verified against an official GE HealthCare source and must be confirmed before use.

GE HealthCare does not publish an official cross-reference table with third-party batteries. The alternatives indicated below share chemistry, voltage and capacity, but come from another cell manufacturer, so they are considered comparable at category level, not 1:1 interchangeable; before replacing, it must be validated field by field (voltage, capacity, dimensions, connector type and terminal orientation).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Yuasa NP series (VRLA, valve-regulated) NP2.6-12 Comparable by category (not interchangeable 1:1) Sealed lead-acid 12 V / 2.6 Ah, Faston 4.8 mm terminal (F1 / 0.187″); same chemistry and voltage as the original; verify housing dimensions, connector and terminal orientation before assembly.
Power Sonic PS series (general use) PS-1226 Comparable by category (not interchangeable 1:1) 12 V / 2.6 Ah, maintenance-free SLA, Faston 4.8 mm terminal (F1); standard format compatible in chemistry and voltage; validate dimensions and fixing in the monitor compartment.

There is no equivalence table validated by the manufacturer (GE HealthCare) that cross-references 17013 with third parties; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Identify the monitor: this battery corresponds to the CardioCap 5 / CardioCap monitors from GE HealthCare. If your equipment is from another series (Dash, Carescape, etc.), it is not interchangeable with this reference.
  • Check the label: confirm voltage (12 V), capacity (2.6 Ah) and terminal type (Faston 4.8 mm) before replacing the cell. Do not use batteries of a different chemistry without validation from the technical service.
  • Replacement: carry out the change with the monitor switched off and leave the equipment connected to the mains after assembly to complete the charge; check that the battery indicator reflects the new status.
  • Wear symptoms: clearly reduced autonomy or low battery warnings within a few hours of charging indicate that the accumulator has reached the end of its service life.
  • Other GE HealthCare family references in catalogue: we have spare parts for GE monitors (e.g. ref. 88881004 for Dash 2500, ref. 88881157 for B450 or ref. 88888819 for Carescape B650, among others). If you manage a mixed fleet, consult our catalogue of monitor batteries.
  • Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department indicating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order.

Additional information

Nominal voltage

12 V

Nominal capacity

2.6 Ah

Technology

Sealed lead-acid (SLA/VRLA), rechargeable, maintenance-free

Terminals

Faston tab 187 (4.8 mm)

Manufacturer reference

17013 (GE HealthCare)

Compatibility

Monitors: GE HealthCare CardioCap 5 (CardioCap /5) and CardioCap

Operating temperature

-15 °C to 50 °C

Rechargeable

Yes

Regulatory standard

RoHS; JIS; UL1778; UL94V-0

Intended use

Hospital, ICU, operating theatre, anaesthesia, emergency, mobile units and intra-hospital transport

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “GE HealthCare CardioCap 5 12V 2.6Ah sealed lead-acid (SLA) battery – Spare part MFR 17013 | Ref. 88888116”

Your email address will not be published. Required fields are marked *