Description
1. Backup battery for your Fukuda Denshi DS5100 monitor
At Cahnos we offer you the rechargeable nickel-metal hydride (Ni-MH) battery, 12 V and 3.8 Ah, for the Fukuda Denshi DS5100 vital signs monitor, identified by the original reference 10TH-2400A-WC1-1 and by the Cahnos reference 88881345.
It is the replacement part that guarantees the equipment’s operability in portable mode: continuous monitoring of ECG, SpO₂, blood pressure and respiration without interruptions when the monitor is disconnected from the mains or moved within the facility. A critical component for emergency departments, ICUs, operating theatres, inpatient wards and medical transport units that need to keep the monitoring fleet always available.
2. Technical explanation: how this battery works
The Fukuda Denshi DS5100 vital signs monitor incorporates an internal rechargeable battery that powers the device’s electronics and the screen when there is no mains power. This pack provides a nominal voltage of 12 V and a capacity of 3.8 Ah (3800 mAh), which supplies approximately 45.6 Wh of useful energy to sustain prolonged monitoring sessions in critical conditions.
Ni-MH chemistry offers good energy density, low self-discharge and no memory effect, with a stable discharge curve that allows the device and its charger to operate within the parameters specified by the manufacturer. Charging is performed by the monitor itself when the mains cable is connected. Replacement is carried out in the device’s specific compartment without specialised tools; it is recommended to check the label of the removed battery and complete a charge cycle before putting the monitor into service.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88881345 |
| Original manufacturer reference | 10TH-2400A-WC1-1 (Fukuda Denshi) |
| Documented factory designations | BATT/110354, EE090103, 10TH-3500A-WC1, B11466 (same pack family, according to specialised distribution) |
| Product type | Rechargeable replacement battery for vital signs monitor |
| Technology | Ni-MH (nickel-metal hydride) |
| Nominal voltage | 12 V |
| Capacity | 3.8 Ah (3800 mAh) |
| Energy | ≈ 45.6 Wh |
| Dimensions approx. (L x W x H) | 84.8 x 68–69.8 x 34.2 mm (according to specialised distribution catalogue; verify compartment dimension) |
| Approximate weight | ≈ 570 g |
| Rechargeable | Yes, integrated charging via the monitor |
| Compatible equipment | Vital signs monitor Fukuda Denshi DS5100 (Denshi 5100 Monitor, Denshi DS5100E Monitor) |
| Application | Power supply in portable mode: ECG, SpO₂, blood pressure and respiration; emergency departments, ICU and medical transport |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations |
4. Equivalences and Cross-References
Code notice: the reference that identifies this battery in the distribution chain is 10TH-2400A-WC1-1, corresponding to the Fukuda Denshi DS5100 monitor. Specialised distribution sources consistently document the original designations BATT/110354, EE090103, 10TH-3500A-WC1 and B11466 for the same equipment family; as they have not been cross-checked against the official Fukuda Denshi data sheet, they are classified as unverified and must be validated against the label of the removed battery.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Fukuda Denshi | Original DS-5100 battery (Denshi 5100 / DS5100E) | BATT/110354 | Not verified | Code documented by specialised distribution as an original part for the DS-5100, alongside 10TH-2400A-WC1-1; same Ni-MH chemistry, 12 V / 3.8 Ah. Not cross-checked against the manufacturer’s official data sheet. Validate against the label of the removed pack. |
| Fukuda Denshi | Original DS-5100 battery (Denshi 5100 / DS5100E) | EE090103 | Not verified | Factory designation cited alongside 10TH-2400A-WC1-1 for the DS-5100 in distribution catalogues. Same nominal ratings (12 V / 3.8 Ah). Validate the code printed on the batch. |
| Fukuda Denshi | Original DS-5100 battery (Denshi 5100 / DS5100E) | 10TH-3500A-WC1 | Not verified | Cited alongside 10TH-2400A-WC1-1 and B11466 as an original part for the DS-5100 family. Validate the code printed on the label before replacing. |
| Fukuda Denshi | Original DS-5100 battery (Denshi 5100 / DS5100E) | B11466 | Not verified | Code documented for the same DS-5100 equipment family in distribution sources. Same pack configuration. Validate against the removed battery. |
| Cameron Sino | Ni-MH replacement for Fukuda Denshi DS-5100 | CS-FXS510MD | Comparable by category (not interchangeable 1:1) | Third-party Ni-MH replacement, 12 V / 3800 mAh (45.6 Wh), with declared dimensions 84.8 x 69.8 x 34.2 mm and EAN 4894128110712; according to its manufacturer, it replaces 10TH-2400A-WC1-1, BATT/110354, EE090103, 10TH-3500A-WC1 and B11466. Verify fit, connector and authenticity before fitting. |
There is no equivalence table validated by the equipment manufacturer that cross-references this reference with third parties; consult the technical department before using it in tenders. Numerous generic 3800 mAh replacements are available on the market that declare compatibility based on reference 10TH-2400A-WC1-1; they are not listed because no verified official technical data sheet from the pack manufacturer itself is available.
5. Selection tips and variants of interest
- Verify the exact model of the device: this battery is the one indicated for the Fukuda Denshi DS5100 (and the Denshi 5100 / DS5100E variants). Before purchasing, confirm the monitor’s label.
- Check the reference printed on the original battery: if it matches 10TH-2400A-WC1-1, or the documented designations BATT/110354, EE090103, 10TH-3500A-WC1 or B11466, this spare part is the direct replacement.
- Do not confuse it with other monitoring batteries: each equipment family supports a specific voltage and capacity. The 14.8 V batteries of the DS-7100 (ref. Cahnos 88888938) or the 9.6 V batteries of the CardiMax electrocardiographs are not interchangeable without prior technical validation.
- Ni-MH pack maintenance: perform full charge cycles, avoid prolonged deep discharges and, if the equipment is to remain unused for several weeks, leave the battery charged and check the level periodically. If the battery life drops markedly, replace the pack.
- Environmental management: take the exhausted battery to a specialised collection point (WEEE); do not dispose of it in the general waste container.
- Institutional purchasing: for tenders, ongoing supply contracts or large volumes, contact our technical-commercial department to confirm the exact reference, compatibility and formal quotation.





Reviews