Description
1. Backup battery for your Fukuda Denshi DS7100 monitor
At Cahnos we offer you the rechargeable lithium-ion battery of 14.8 V and 4.4 Ah for the vital signs monitor Fukuda Denshi DS7100 (Dynascope line), identified with the original reference T4AUR18650 and with the Cahnos reference 88888938.
It is the replacement that guarantees the equipment’s operability in portable mode: ECG, SpO₂, blood pressure and respiration monitoring without interruption when the monitor is disconnected from the mains or moved within the facility. A critical component for emergency departments, ICUs, operating theatres, hospital wards and medical transport units that need to keep the monitoring fleet always available.
2. Technical explanation: how this battery works
The Fukuda Denshi DS7100 vital signs monitor incorporates an internal rechargeable battery that powers the equipment’s electronics and the screen when there is no mains power. This battery provides a nominal voltage of 14.8 V (typical configuration of four 3.7 V nominal lithium-ion cells in series, 18650 format according to the T4AUR18650 nomenclature itself) and a capacity of 4.4 Ah, providing approximately 65 Wh of useful energy for prolonged monitoring sessions in critical conditions.
Li-Ion chemistry offers high energy density, low self-discharge and no memory effect, with a stable discharge curve that allows the equipment and its charger to work within the parameters specified by the manufacturer. Replacement is carried out in the monitor’s specific compartment without specialised tools; it is recommended to check the label of the removed battery and complete a charge cycle before putting the equipment into service.
3. Technical Specifications
Data cross-checked with the technical data sheet from specialised distribution for biomedical batteries for the same code (VLAD, reference 88888938) and with documentation from cell manufacturers and authorised distributors.
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888938 |
| Original manufacturer reference | T4AUR18650 (Fukuda Denshi) |
| Product type | Rechargeable replacement battery for vital signs monitor |
| Technology | Li-Ion (lithium-ion), 18650 format cells according to the reference nomenclature |
| Nominal voltage | 14.8 V |
| Capacity | 4.4 Ah |
| Approximate energy | ≈ 65 Wh |
| Dimensions approx. (L x W x H) | 130 x 77 x 18 mm (according to the specialised distribution data sheet) |
| Approximate weight | 0.41 kg |
| Rechargeable | Yes |
| Compatible equipment | Vital signs monitor Fukuda Denshi DS7100 (Dynascope) |
| Application | Power supply in portable mode; hospitals, emergency departments, ICU and medical transport |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations |
4. Equivalences and Cross-References
Code notice: the reference identifying this battery in the distribution chain (T4AUR18650) corresponds to the Fukuda Denshi DS7100 monitor. Specialised distribution sources document for the same DS-7100 / DS7100 Dynascope equipment family the original codes T4UR18650-F-2-4644 and MSE-OM11413; as they have not been cross-checked against the official Fukuda Denshi data sheet, they are classified as unverified and must be validated against the label of the removed battery. The references from other manufacturers listed below are classified as comparable by category, not 1:1 interchangeable, and require verification of dimensions, connector and housing before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Fukuda Denshi | Original DS-7100 Dynascope battery | MSE-OM11413 | Not verified | Code documented by specialised distribution as the original battery for the DS-7100; not cross-checked against the manufacturer’s official data sheet. Check the label of the removed battery before replacing. |
| Fukuda Denshi | Original DS-7100 Dynascope battery | T4UR18650-F-2-4644 | Not verified | Cited alongside MSE-OM11413 as an original part of the DS-7100 family; same voltage (14.8 V) and cell configuration. Validate the code printed on the monitor’s batch. |
| Cameron Sino | Li-Ion replacement for Fukuda Denshi DS-7100 | CS-FDS710MD | Comparable by category (not interchangeable 1:1) | Li-Ion 14.8 V / 4400 mAh (≈ 65 Wh) with dimensions 132.8 x 80.3 x 20.0 mm compared to the ≈ 130 x 77 x 18 mm of this data sheet and declared weight ≈ 380 g; according to its manufacturer it replaces T4UR18650-F-2-4644, MSE-OM11413, T10HRAAC-4781 and CSA27090. Verify fit and connector before mounting. |
There is no equivalence table validated by the equipment manufacturer that cross-references this reference with third parties; consult the technical department before using in tenders. In specialised distribution cross-reference tables, the OEM codes T10HRAAC-4781 and CSA27090 also appear for the same cell configuration; they have not been cross-checked against the official data sheet and must be validated against the batch label. Higher-capacity versions (14.8 V / 5400 mAh, ≈ 80 Wh, dimensions 132.8 x 80.3 x 20.0 mm) documented by specialised biomedical battery suppliers are also distributed for the same DS-7100; in all cases, cross-check the chemistry and capacity with the monitor’s charging electronics before replacing.
5. Selection tips and variants of interest
- Verify the exact model of the equipment: this battery is the one indicated for the Fukuda Denshi DS7100 (Dynascope). Before purchasing, confirm the monitor’s label.
- Check the reference printed on the original battery: if it matches T4AUR18650, or the documented codes T4UR18650-F-2-4644, MSE-OM11413, T10HRAAC-4781 or CSA27090, this spare part is the direct replacement.
- Do not confuse it with other monitoring batteries: each equipment family supports a specific voltage and capacity; batteries of 11.1 V, 12 V or 10.8 V from other monitors are not interchangeable without prior technical validation.
- Market data: some distribution datasheets associate the same battery format with the DS-7000/DS7001 line and the Dynascope bedside monitors from Fukuda Denshi; this information comes from commercial documentation, not from official manufacturer specification, and must be verified.
- After installation: perform a full charge cycle before putting the monitor into service and check the equipment’s battery indicator.
- Environmental management: deliver the depleted Li-Ion battery to a specialised collection point (WEEE); do not dispose of it in the general waste container.
- For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.