We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable Battery Edan M3 MFR TWSLB-008 Li-Ion 14.8V 4.4Ah (65.12Wh) for Vital Signs Monitors M3, M3A and M3B | Ref. 88888817

128,00 €

Rechargeable lithium-ion battery TWSLB-008, 14.8 V and 4.4 Ah (65.12 Wh), direct replacement for the original reference for Edan M3, M3A and M3B vital signs monitors. Designed to maintain continuous monitoring in emergency departments, patient transfers and power cuts, with integrated automatic recharging and direct mounting in the equipment compartment, without tools or adaptations. Ref. Cahnos 88888817.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888817

Description

1. Reliable power for your Edan vital signs monitor

The Edan M3 MFR TWSLB-008 battery (ref. Cahnos 88888817) is the power replacement for Edan vital signs monitors of the M3 series: M3, M3A and M3B. Designed for emergency services, hospitalisation wards, consultations and intra-hospital transport, it ensures the monitor remains operational when disconnected from the mains: patient transfers, supply interruptions or critical situations where monitoring continuity cannot allow pauses.

It is a rechargeable lithium-ion cell, ready to install and compatible with the equipment’s original charger. It directly replaces the original reference TWSLB-008 and provides a generous energy reserve for prolonged off-grid working sessions.

2. How this battery works

The Edan vital signs monitors of the M3 series are portable bedside and transport devices that integrate a screen, parametric modules (ECG, SpO2, NIBP, temperature) and signal processing electronics. To operate without depending on the mains, they incorporate an internal rechargeable lithium-ion (Li-ion) battery, a chemistry that offers high energy density in a light and compact format, without memory effect and with a stable discharge curve: the voltage remains practically constant until the end, avoiding abrupt cuts in the middle of a monitoring session.

This cell delivers a nominal voltage of 14.8 V with a capacity of 4.4 Ah (4,400 mAh), which represents a total energy of 65.12 Wh. It recharges automatically while the monitor remains connected to its charger or to the mains. When autonomy is noticeably reduced or the equipment warns of low battery after a few hours of charging, it is time to replace the accumulator. The internal management system (BMS) supervises the charging and discharging of the cell, adding an extra layer of security to the set.

3. Technical Specifications

Characteristic Specification
Reference Cahnos (SKU) 88888817
Original equipment reference (OEM) TWSLB-008 (also in distribution HYLB-1049 / HYLB-1264)
Application Edan M3, M3A and M3B vital signs monitors
Battery type Lithium-ion (Li-ion), rechargeable
Nominal voltage 14.8 V
Capacity 4.4 Ah (4,400 mAh)
Energy 65.12 Wh
Weight Approximately 0.396 kg
Dimensions 146.8 x 69.9 x 20.9 mm
Device manufacturer Edan
Integrated protections BMS: overcharge, over-discharge, overheating and short-circuit
Presentation Unit

Note: the voltage, capacity and energy indicated correspond to the declared specification for reference TWSLB-008. Always check the compartment and connector of your unit before replacement.

4. Equivalences and Cross-References

Reference TWSLB-008 is the code under which Edan identifies the internal battery of the vital signs monitors of the M3 series (M3, M3A and M3B). In specialised distribution, the same pack is also documented under the codes HYLB-1049 and HYLB-1264, as well as the numbers 21.21.064168 and 009-CA00045 in third-party catalogues; none of these extensions has been verified against an official Edan table, so they are considered pending confirmation with the manufacturer before use.

There is no equivalence table validated by Edan that authorises third-party batteries for the TWSLB-008. The reference listed below comes from a replacement battery manufacturer that declares it replaces this pack and is classified as comparable by category (not 1:1 interchangeable); before replacing, each must be verified one by one: voltage, capacity, chemistry (Li-ion), connector and compartment dimensions.

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
Cameron Sino Medical Series (Edan) CS-EDM310MD Comparable by category (not interchangeable 1:1) Li-ion 14.8 V / 5,200 mAh (76.96 Wh); declared as a replacement for TWSLB-008 and HYLB-1049 for Edan M3 in multiple specialised distribution datasheets; declared dimensions ≈146.5 x 72.0 x 19.0 mm and ≈516 g. Capacity higher than the original cell (5.2 Ah vs 4.4 Ah): check connector, charging protocol and fit in the compartment before replacement.

There is no equivalence table validated by the manufacturer that authorises third-party batteries; consult the technical department before use in tenders. Before any replacement with other brand spare parts, voltage, capacity, chemistry, connector and dimensions must be checked against the specific unit.

5. Selection tips and variants of interest

Identify the exact model: this battery corresponds to the Edan M3, M3A and M3B vital signs monitors. Also check the label of the installed battery: the original reference may appear as TWSLB-008, HYLB-1049 or HYLB-1264. Do not swap it for batteries from other models of the same brand without technical validation: each monitor mounts a cell with specific voltage, capacity and dimensions.

Battery care: keep the cell charged if the equipment is to remain idle for long periods and replace the battery when autonomy is noticeably reduced or the equipment indicates low battery. Use only the monitor’s original charger to respect the Li-ion charging parameters and avoid habitual deep discharges.

Variants of the same Edan family in Cahnos: Edan M9 MFR HYLB-231 battery (ref. 88881198, 14.8 V / 2.6 Ah), Edan SE-1200 series MFR TNSLB-005 battery (ref. 88881129, 14.4 V / 2.6 Ah), Edan SE-601 MFR HYLB-727 battery (ref. 88881059, 14.8 V / 5.2 Ah) and Edan 6010 MFR HYLB-722 battery (ref. 88890216, 14.4 V / 2.6 Ah). Do not interchange these references between models: each device accepts a specific voltage, capacity and geometry.

For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formal quotation.

Additional information

Application

Edan M3, M3A and M3B vital signs monitors

Manufacturer reference

TWSLB-008 (also in distribution HYLB-1049 / HYLB-1264)

Battery type

Lithium-ion (Li-ion), rechargeable

Nominal voltage

14.8 V

Capacity

4.4 Ah (4,400 mAh)

Energy

65.12 Wh

Dimensions

146.8 x 69.9 x 20.9 mm

Weight

Approximately 0.396 kg

Device manufacturer

Edan

Compatibility

M3, M3A, M3B

Integrated protections

BMS: overcharge, over-discharge, overheating and short-circuit

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Battery Edan M3 MFR TWSLB-008 Li-Ion 14.8V 4.4Ah (65.12Wh) for Vital Signs Monitors M3, M3A and M3B | Ref. 88888817”

Your email address will not be published. Required fields are marked *