Stryker Flyte MFR 0408-660-000 Li-Ion 7.4V 5.0Ah (Power Pack Extended Life) Battery for Surgical Helmet and Personal Protection | Ref. 88881180

376,00 €

Rechargeable Li-Ion battery 7.4 V / 5.0 Ah (37 Wh) for the Stryker Flyte system: surgical helmet (Casque Chirurgical Flyte) and personal protection system with integrated airflow. Replaces the original reference 0408-660-000 (Power Pack Extended Life), compatible with the Stryker Steri-Shield charger (0408-655 family). Dimensions 79 x 41 x 43 mm and 0.221 kg; extended battery life for full operating theatre days without depending on the mains power supply. Traceable spare part for hospital purchasing, medical electronics services and maintenance of personal protective equipment.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881180

Description

1. Replacement battery for the Stryker Flyte system

At Cahnos we make available the rechargeable lithium-ion battery for the Stryker Flyte system (original manufacturer reference 0408-660-000), the “Power Pack Extended Life” accumulator with which Stryker equips its Flyte surgical helmet (Casque Chirurgical Flyte) and its Flyte personal protection system.

It is the spare part required by medical electronics services, operating theatre maintenance, sterilisation units and hospital purchasing departments to restore full autonomy to protection equipment with integrated airflow, with the reliability of a traceable component and at a very competitive cost compared with the official replacement via the manufacturer.

2. Technical explanation of the equipment

The Stryker Flyte is a surgical helmet and personal protection system (GMDN: Surgical helmet system; Stryker UDI registration in GUDID, primary DI 04546540591654, catalogue No. 0408660000) that integrates cap, visor, frontal light and an airflow ventilation system that helps maintain a sterile field for the surgical team. The battery is housed in the power pack (Power Pack) and powers the system without cables or dependence on the mains supply.

This battery uses lithium-ion chemistry in a 2S configuration (two cells in series) to deliver 7.4 V nominal with 5.0 Ah capacity (≈37 Wh) and incorporates integrated protection electronics against overcharge, overdischarge and overcurrent. It works with the Stryker Steri-Shield 8-bay charger (family 0408-655). When the helmet’s autonomy is noticeably reduced or the equipment does not complete the full operating theatre day, it is time to replace the battery with this reference. Installation is direct in the original pack compartment, without tools or adaptations.

3. Technical Specifications

It replaces the original reference 0408-660-000 with the same performance and compatibility as the pack supplied with the new equipment.

Parameter Specification
Device manufacturer Stryker Corporation
Original manufacturer reference 0408-660-000 (Power Pack, Extended Life)
UDI catalogue number (GUDID) 0408660000 — primary DI 04546540591654
SKU Cahnos 88881180
Battery type Rechargeable, with integrated protection electronics
Technology Lithium-ion (Li-Ion), 2S configuration
Nominal voltage 7.4 V
Capacity 5.0 Ah (5000 mAh)
Energy 37 Wh (Stryker GUDID UDI record: 39 Wh)
Dimensions (length x width x height) 79 x 41 x 43 mm
Approximate weight 0.221 kg
Application Stryker Flyte surgical helmet (Casque Chirurgical Flyte) and Flyte personal protection system
Compatible charger Stryker Steri-Shield 8-bay, family 0408-655 (230 V version: 0408-655-001)
Regulatory classification FDA GUDID Class I (GMDN: Surgical helmet system); non-implantable
Presentation 1 unit

Note: reference 0408-660-000 corresponds to a single battery pack (unit), not a batch. The catalogue data sheet states 37 Wh (5.0 Ah x 7.4 V); the Stryker UDI record in GUDID identifies the pack as “Power Pack, Extended Life 7.4V 39Wh”. Always verify the reference printed on the removed pack before placing the order.

4. Equivalences and Cross-References

Reference 0408-660-000 is the 7.4 V Power Pack Extended Life that Stryker fits to the Flyte surgical helmet and the Flyte personal protection system. The third-party alternatives cited below have been checked against battery manufacturers’ data sheets and specialist distribution and are classified as comparable by category, not 1:1 interchangeable: they share chemistry (Li-Ion), voltage (7.4 V) and target platform, but come from independent manufacturers and may vary slightly in declared capacity and dimensions.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cameron Sino Li-Ion medical battery for Stryker Casque Chirurgical Flyte / Flyte Personal Protection System CS-SKR408MD (EAN 4894128164777) Comparable by category (not interchangeable 1:1) Direct replacement, Li-Ion 7.4 V / 5200 mAh / 38.48 Wh; dimensions 79.70 x 41.50 x 44.00 mm, grey. Capacity slightly higher than the original (5200 vs 5000 mAh) and differences of tenths of a mm; consistently documented across several specialist distributors. Verify fit and BMS behaviour during the first cycle.

On the market there are compatible products from other brands (FOUNCY, SPANN, BELLV, XSPLENDOR, KingSener, MedicalBatteryDirect, among others) that cover reference 0408-660-000 with 5200 mAh cells, but as they do not have a uniform, verifiable public reference code they are not included in the table.

There is no equivalence table validated by the manufacturer (Stryker) that authorises third-party packs for reference 0408-660-000 or that cross-references this battery with other systems; the above alternatives come from battery manufacturers and specialist distribution and are offered as comparable by category. Consult our technical department before using this reference in tenders or maintenance contracts.

5. Selection tips and variants of interest

  • Identify the exact reference: check the code 0408-660-000 and the model of your equipment (Casque Chirurgical Flyte or Flyte Personal Protection System) on the label of the removed pack. Always order by SKU Cahnos 88881180 to avoid confusion.
  • Do not confuse with other Stryker operating theatre batteries: Stryker cordless surgical motors and drills (e.g. 4112, 4115, 7126, 7222 or 6212) use voltages of 9.6–10.8 V with different Ni-Cd, Ni-MH or Li-Ion chemistries and are not interchangeable with the Flyte pack (7.4 V).
  • Correct charger: use the Stryker Steri-Shield charger (0408-655 family; European version 0408-655-001, 230 V, 50-60 Hz, 0.9 A) and complete the charge cycle before first use. If a third-party replacement is used, a full charge-discharge cycle is recommended so that the equipment BMS recalibrates.
  • Li-Ion battery maintenance: avoid repeated deep discharges, recharge it when the equipment indicates low battery and keep it in a cool, dry place (ideally at 40–60% charge) if it is to be stored.
  • Plan rotation stock in PPE fleets: with two packs per unit (one in use and one charging), stoppages during long operating theatre sessions are eliminated. For mixed fleets or institutional orders, contact our technical-commercial department to confirm compatibility and a formal quotation.

Additional information

Battery type

Rechargeable lithium-ion (Li-Ion), 2S configuration

Nominal voltage

7.4 V

Capacity

5.0 Ah (5000 mAh)

Energy

37 Wh (Stryker GUDID UDI record: 39 Wh)

Manufacturer reference

0408-660-000 (Power Pack Extended Life)

Compatibility

Stryker Flyte (Casque Chirurgical Flyte), Flyte Personal Protection System

Application

Surgical helmet / personal protection system with airflow

Dimensions

79 x 41 x 43 mm

Weight

0.221 kg

Compatible charger

Stryker Steri-Shield 8-bay, family 0408-655 (230 V: 0408-655-001)

Regulatory classification

FDA GUDID Class I (GMDN: Surgical helmet system)