We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Stryker 4112 Battery (MFR 4112000000) Ni-Cd 9.6V 0.6Ah for Wireless Surgical Motor STR-4000 | Ref. Cahnos 88889208

360,00 €

Rechargeable nickel-cadmium (Ni-Cd) battery, 9.6V and 0.6Ah for the Stryker 4112 wireless surgical motor/drill (STR-4000 motor series). Traceable replacement that substitutes the manufacturer’s original reference 4112000000 and restores the equipment’s required autonomy in the operating theatre, without depending on mains power or power cables. Direct installation in the motor’s original compartment, without tools or adaptations, and compatible with the chargers of the Stryker 4112 family. Ref. Cahnos 88889208: guaranteed delivery, proven quality and technical advice for medical electronics services, operating theatre maintenance, traumatology and hospital purchasing.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88889208

Description

1. Replacement battery for the Stryker 4112 surgical motor

At Cahnos we offer the rechargeable battery for the Stryker 4112 surgical motor (Ref. Cahnos 88889208), corresponding to the original manufacturer reference 4112000000. It is a nickel-cadmium (Ni-Cd) battery of 9.6V and 0.6Ah that allows working with complete freedom of movement in the operating theatre, without power cables or mains dependency.

It is the ideal solution for medical electronics departments, operating theatre maintenance, traumatology and hospital purchasing that need to replace the battery of their Stryker 4112 series drills with a reliable, traceable part at a very competitive cost compared to the official spare part.

2. Technical explanation

The Stryker 4112 belongs to the family of cordless surgical motors (Cordless Driver, STR-4000 series) from Stryker Instruments, commonly used in orthopaedic and large bone surgery (drilling, reaming and screw insertion). The motor is powered by a rechargeable battery pack attached to the instrument body: while the battery is charged, the equipment provides constant torque and rotational speed without interfering with the surgeon’s ergonomics.

This battery uses nickel-cadmium (Ni-Cd) chemistry, 9.6V nominal voltage and 0.6Ah capacity, with an approximate weight of 0.325 kg. When the motor’s runtime decreases noticeably or the equipment does not maintain torque during long procedures, it is time to replace the battery with this reference. Installation is direct in the motor’s original compartment, without tools or adapters.

3. Technical Specifications

Parameter Specification
Application Stryker 4112 surgical drill/motor (STR-4000 cordless motor series)
Original manufacturer reference 4112 / 4112000000
Reference Cahnos (SKU) 88889208
Battery type Rechargeable battery
Technology Nickel-cadmium (Ni-Cd)
Nominal voltage 9.6 V
Capacity 0.6 Ah (600 mAh)
Approximate weight 0.325 kg
Rechargeable Yes (chargers from the Stryker 4112 family)
Use Power supply for surgical drills and motors in the operating theatre
Presentation 1 unit

Note: reference 4112000000 corresponds to a single battery pack (unit). Always check the reference printed on the removed battery before placing the order.

4. Equivalences and Cross-References

The original reference 4112 (4112000000) is the Ni-Cd pack of 9.6V / 0.6Ah that Stryker mounts on its 4112 series cordless motors. This same electrical format matches that of the Stryker 4212 motor (MFR 4212000000, also 9.6V / 0.6Ah Ni-Cd), which shares chemistry, voltage and capacity; in fact, spare parts such as the Unipower B11036 are expressly documented for both models (Ref. Cahnos of the 4212 variant: 88881068).

The third-party alternatives listed below have been cross-referenced against battery manufacturer datasheets and specialist distribution (R&D Batteries, BatteryTex, OSI Batteries, NCE Empowering Safety, MedEquip Depot, PartsSource) and are classified as comparable by category, not interchangeable 1:1: they share chemistry (Ni-Cd), voltage (9.6V) and compatibility with the Stryker 4112, but come from independent manufacturers and may vary in declared capacity (0.65Ah vs 0.6Ah), format (complete vs insert) or service conditions (rebuild with previous core).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
R&D Batteries Stryker Instruments 4112 (STR-4000) – Complete 5758-A Comparable by category (not interchangeable 1:1) Complete direct replacement spare part, Ni-Cd 9.6V / 0.65Ah (capacity slightly higher than original); consistently documented in several specialist sources (BatteryTex, R&D, PartsSource) and includes new housing.
R&D Batteries Stryker Instruments 4112 – Insert 5758-I Comparable by category (not interchangeable 1:1) Insert/cell only: requires the original housing and connector (core required) for assembly; Ni-Cd 9.6V / 0.65Ah. It is not a complete 1:1 spare part.
OSI Batteries Stryker 4112 Battery Equivalent STR-4000 Comparable by category (not interchangeable 1:1) Biomedical replacement battery for Stryker 4112, Ni-Cd 9.6V / 0.65Ah; verify connector and compartment dimensions before replacing.
NCE Empowering Safety Stryker Instruments 4112 (STR-4000) Complete N1485 Comparable by category (not interchangeable 1:1) Complete spare part, Ni-Cd 9.6V / 0.65Ah, according to battery manufacturer datasheet; appears as a cross-reference of 5758-A in R&D Batteries.
Unipower Ni-Cd battery for Stryker 4112 / 4212 B11036 Comparable by category (not interchangeable 1:1) Documented for Stryker 4112 and 4212 motors (same electrical format 9.6V / 0.6Ah Ni-Cd); rebuild service on the original battery sent by the customer.
MK Battery Equivalent medical battery of 5758-I BMED11036 Comparable by category (not interchangeable 1:1) Appears as a cross-reference of the 5758-I insert in the R&D Batteries catalogue; confirm specifications with the supplier before replacing.

There is no equivalence table validated by the device manufacturer (Stryker) that authorises third-party packs for reference 4112000000 or that cross-references this battery with motors from other manufacturers (e.g. De Soutter, Zimmer, Conmed); the previous alternatives come from battery manufacturers and specialist distribution and are offered as comparable by category. Consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Identify the exact reference: check the code 4112 / 4112000000 on the label of the removed battery. Always order by reference (SKU Cahnos 88889208) to avoid confusion with other batteries in the Stryker family.
  • Do not confuse with other variants of the family: the Stryker 4115 (9.6V / 1.3Ah Ni-Cd, Ref. Cahnos 88889207), 6126 (9.6V / 2Ah Ni-MH), 6212 (9.6V / 1.3Ah Li-Ion) or 7126/7222 (10.8V Li-Ion) batteries belong to other platforms, with different chemistry, capacity or voltage, and are not interchangeable with the 4112.
  • Ni-Cd battery maintenance: avoid repeated deep discharges, recharge the battery when the motor loses power and do not store it fully discharged to extend its service life.
  • Replace upon signs of wear: clearly reduced runtime or loss of torque during long procedures indicate that the battery has reached the end of its service life.
  • Mixed fleets and institutional orders: if you manage fleets of Stryker motors from several series or need volume pricing, contact our technical-commercial department to confirm compatibility and a formal quotation.

Additional information

Battery type

Rechargeable Ni-Cd

Nominal voltage

9.6 V

Capacity

0.6 Ah (600 mAh)

Application

Stryker 4112 surgical drill/motor (STR-4000 cordless motor series)

Manufacturer reference

4112 / 4112000000

Weight

0.325 kg

Rechargeable

Yes (chargers from the Stryker 4112 family)

Use

Power supply for surgical drills and motors in the operating theatre

Technology

Nickel-cadmium (Ni-Cd)

Approximate weight

0.325 kg

Compatibility

Stryker 4112 surgical drill/motor (STR-4000 series)

Presentacion

Unit

Alimentacion

Rechargeable battery

Reviews

There are no reviews yet.

Be the first to review “Stryker 4112 Battery (MFR 4112000000) Ni-Cd 9.6V 0.6Ah for Wireless Surgical Motor STR-4000 | Ref. Cahnos 88889208”

Your email address will not be published. Required fields are marked *