We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

De Soutter AB-450 (Stryker AB450) 10.8V Ni-MH 1Ah Battery for Surgical Drill | Original Ref. 14510 | Ref. Cahnos 88881124

696,00 €

Rechargeable battery 10.8V Ni-MH, 1Ah for the De Soutter AB-450 aseptic surgical drill (original ref. 14510). Restores runtime and motor torque in trauma and large-bone procedures, with direct installation in the AH-450 and AH-700 aseptic housings. The Ni-MH chemistry offers very low memory effect, contains no cadmium and supports repeated charge cycles with the De Soutter CA-450 adapter and BC-700 charger. Reliable, traceable and competitively priced spare part for medical electronics services, theatre maintenance and hospital purchasing. Reference Cahnos 88881124; always order by reference to avoid confusion with other batteries in the De Soutter family.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88881124

Description

1. Reliable and traceable power for your De Soutter AB-450 surgical drill

At Cahnos we provide you with the rechargeable battery for the De Soutter AB-450 aseptic cordless surgical drill (historically marketed as Stryker AB450), corresponding to the manufacturer’s original reference 14510 (Ref. Cahnos 88881124). It is a nickel-metal hydride (Ni-MH) rechargeable battery of 10.8 V and 1 Ah (10.8 Wh) that restores to the equipment the autonomy and torque needed to work with total freedom of movement in the operating theatre.

It is the ideal solution for medical electronics services, operating theatre maintenance, traumatology and hospital purchasing departments that need to replace the battery of their De Soutter aseptic motors with a reliable, traceable part at a very competitive cost compared to the official replacement.

2. Technical explanation: how this battery works

The De Soutter AB-450 surgical drill is a cordless aseptic motor that houses the battery in a sealed housing (housing aseptic), so that the assembly can undergo the cleaning and sterilisation cycles of the operating theatre without separating electronics or battery from the instrument. This compact 10.8 V battery supplies power to the motor during drilling, milling and screwdriving in orthopaedic and large-bone surgery, maintaining the rotation speed and torque constantly, without interfering with the surgeon’s ergonomics or depending on an external power supply.

Ni-MH chemistry offers a very low memory effect, contains no cadmium and supports repeated charge and discharge cycles with the equipment’s own charger. When battery life is noticeably reduced or the motor loses power in long procedures, it is time to replace the battery with this reference. Installation is direct in the original aseptic housing AH-450 (ref. 14520) or AH-700 (ref. 16140), without tools or adaptations.

3. Technical Specifications

Pack data cross-checked with De Soutter’s official accessories catalogue (Accessories 162-EN, order code 14510) and with the technical documentation from biomedical spare parts manufacturers and specialised distribution.

Characteristic Specification
Application De Soutter AB-450 aseptic cordless surgical drill; handpieces MDX, KDX, CDX, RDX and TDZ
Reference Cahnos (SKU) 88881124
Original manufacturer reference 14510 (De Soutter order code)
Technology Ni-MH (nickel-metal hydride), rechargeable
Nominal voltage 10.8 V
Capacity 1 Ah (1,000 mAh)
Energy 10.8 Wh
Weight Approximately 0.3 kg (spare parts technical documentation: ≈ 0.247 kg)
Dimensions ≈ 48 x 49 x 57 mm (according to technical documentation from spare parts manufacturers; the original commercial datasheet did not declare them)
Compatible aseptic housings AH-450 (ref. 14520) and AH-700 (ref. 16140)
Charger De Soutter CA-450 adapter (ref. 14540) on BC-700 charger
Device manufacturer De Soutter
Presentation 1 unit
Recycling Manage in accordance with WEEE regulations

4. Equivalences and Cross-References

The original reference 14510 corresponds to the aseptic Ni-MH pack of 10.8 V / 1 Ah that De Soutter mounts in the AB-450 system, confirmed in the manufacturer’s official accessories catalogue (Accessories 162-EN: AB-450 Small aseptic battery, 10.8V NiMH, 1000 mAh, order code 14510) and in specialised distribution (Robin Medical Ltd identifies it as an OEM pack for the MDX, KDX, CDX, RDX and TDZ handpieces, with AH-450 ref. 14520 and AH-700 ref. 16140 housings). The code 14510 is not indexed as such in the GUDID/FDA database for this battery; its validation rests on the manufacturer’s official catalogue.

De Soutter does not publish an official equivalence table authorising third-party batteries for reference 14510. The replacement alternatives indicated below share application (AB-450 / ref. 14510), chemistry (Ni-MH), voltage (10.8 V) and dimensions (≈ 48 x 49 x 57 mm); they are classified as comparable by category, not 1:1 interchangeable, as they come from independent manufacturers and offer higher capacity (1.65 Ah vs 1 Ah):

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
AKKUmed (Akkuplanet GmbH) NiMH conversion for De Soutter AB-450 (ref. 14510) 110613-U / AKKP-110613 (GTIN 4064295009823) Comparable by category (not interchangeable 1:1) Ni-MH 10.8 V / 1.65 Ah, dimensions ≈ 48 x 49 x 57 mm, ≈ 0.247 kg, CE compliant; conversion (retrofit) service that requires sending the original battery; capacity higher than the original (1.65 Ah vs 1 Ah). Confirmed in the spare part manufacturer’s datasheet.
Akku Mäser de Soutter AB-450, ref. 14510 505557 Comparable by category (not interchangeable 1:1) Ni-MH 10.8 V / 1650 mAh, dimensions 48 x 49 x 57 mm, 0.247 kg; conversion replacement, not original, for the AB-450 (ref. 14510); capacity higher than the original. Confirmed in the spare part manufacturer’s datasheet.

There is no equivalence table validated by the manufacturer (De Soutter) for reference 14510; the cross-references indicated come from biomedical spare parts manufacturers and specialised distribution, so it is recommended to consult the technical department before use in tendering.

5. Selection tips and variants of interest

  • Identify the exact reference: check the label of the removed battery for code 14510 and the aseptic housing (AH-450, ref. 14520, or AH-700, ref. 16140). Always order by reference (SKU Cahnos 88881124) to avoid confusion with other batteries in the De Soutter family.
  • Respect chemistry and voltage: this battery is Ni-MH, 10.8 V. Do not install packs of a different chemistry or voltage, and do not use a charger other than the De Soutter CA-450 adapter (ref. 14540) with the BC-700 charger, even if the connector might appear compatible.
  • Do not confuse with other variants in the family: the De Soutter AB-702 (14.4 V, ref. 15350, Ref. Cahnos 88881125), AB-600 (9.6 V, ref. 11520, Ref. Cahnos 88888965) and SB-600 (9.6 V Ni-Cd, ref. 11630, Ref. Cahnos 88889778) batteries belong to other platforms, with different voltage or capacity, and are not interchangeable with the AB-450 battery without technical validation.
  • Replace when signs of wear appear: clearly reduced runtime or loss of torque in long procedures indicate that the battery has reached the end of its service life.
  • Storage: if the drill is to remain unused for long periods, recharge it periodically (every 2-3 months) and avoid deep discharges. At the end of its service life, take the battery to a WEEE collection point; never dispose of it as general waste.
  • Institutional orders: for consortia, tenders or maintenance contracts, contact our technical-commercial department at Cahnos to confirm exact compatibility with your batch of drills and obtain a formal quotation with special volume conditions.

Additional information

Manufacturer reference

14510 (De Soutter)

Application

De Soutter AB-450 aseptic cordless surgical drill (marketed as Stryker AB450); handpieces MDX, KDX, CDX, RDX and TDZ

Technology

Ni-MH (nickel-metal hydride), rechargeable

Nominal voltage

10.8 V

Capacity

1 Ah (1,000 mAh)

Energy

10.8 Wh

Weight

Approximately 0.3 kg (technical documentation: ≈ 0.247 kg)

Dimensions

≈ 48 x 49 x 57 mm

Rechargeable

Yes; De Soutter CA-450 charger/adapter (ref. 14540)

Compatible aseptic housing

AH-450 (ref. 14520) and AH-700 (ref. 16140)

Device manufacturer

De Soutter

Recycling

Manage in accordance with WEEE regulations

Charger

De Soutter CA-450 adapter (ref. 14540) with BC-700 charger

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “De Soutter AB-450 (Stryker AB450) 10.8V Ni-MH 1Ah Battery for Surgical Drill | Original Ref. 14510 | Ref. Cahnos 88881124”

Your email address will not be published. Required fields are marked *