Description
1. Backup power for your SPENCER NXT ventilators
At Cahnos we offer you the original replacement battery pack (reference 34019, SKU GM34019), designed as a replacement for the integrated power supply of the SPENCER NXT series electronic ventilators. It is the part indicated by the manufacturer to restore the original autonomy of the equipment in those ventilator codes that incorporate it: 34006 (SPENCER 170 NXT), 34007 (SPENCER 170 NXT KOMPAK) and 34009 (SPENCER 190 NXT). A traceable replacement, with direct fit and consistent quality, intended for emergency services, ambulances, civil protection, assisted transport units and medical electronics and hospital maintenance services.
2. Technical Explanation
The SPENCER NXT electronic ventilators incorporate a power supply module with an internal battery that automatically takes over the equipment’s power supply when no mains electricity is available. While the ventilator remains connected to the mains, the battery stays in charging mode; when it is disconnected, moved or in the event of a power cut, the battery pack powers the control electronics, the ventilator module, the screen and the monitoring systems without interrupting ventilation. This reference 34019 is the original replacement battery pack, designed to be installed in the equipment’s own housing, ensuring the ventilator continues to operate during patient transport. When the autonomy is noticeably reduced or the equipment warns of low battery prematurely, it is time to replace the accumulator with this original reference.
3. Technical Specifications
The replacement battery pack ref. 34019 is intended for SPENCER electronic ventilators whose equipment codes are detailed below.
Available references (compatible equipment)
| Equipment code | Compatible equipment |
|---|---|
| 34006 | SPENCER 170 NXT electronic ventilator |
| 34007 | SPENCER 170 NXT KOMPAK electronic ventilator |
| 34009 | SPENCER 190 NXT electronic ventilator |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 34019 |
| Designation | Battery pack, replacement for SPENCER ventilator |
| Sales unit | 1 pc |
| Device type | Spare part (replacement part) |
| EAN | 8023279340198 |
Note: always verify the equipment reference and the installed battery before placing the order, to confirm that the removed part corresponds to this replacement.
4. Equivalences and Cross-References
Reference 34019 is the distribution code for this replacement battery pack for the SPENCER NXT series electronic ventilators (170 NXT, 170 NXT KOMPAK and 190 NXT). We do not have a manufacturer-validated equivalence table that authorises the direct cross-reference of this reference with battery codes from other suppliers: each unit accepts a specific voltage, chemistry and connector, so the replacement must always be selected according to the exact model and code of the ventilator in use. Within the same manufacturer, the SPENCER NXT family is completed with the replacement corrugated tube (ref. 34035) and the patient circuit (valve + corrugated tube, ref. 34036), while the automatic ventilators in the range (SPENCER 118 NXT, codes 34016 and 34017) share the consumables ecosystem. For any replacement or comparison with third-party products, we recommend verifying compatibility against the manufacturer’s official datasheet before purchase or tender.
5. Selection tips and variants of interest
Identify the exact model of the equipment before replacing the battery: confirm that your ventilator corresponds to codes 34006 (SPENCER 170 NXT), 34007 (170 NXT KOMPAK) or 34009 (SPENCER 190 NXT) and note down the reference of the removed battery. Replace it upon signs of wear: clearly reduced autonomy, premature low battery warnings or the equipment switching off when disconnected from the mains indicate that the accumulator has reached the end of its service life. After installation, allow a full charge before putting the ventilator into service and carry out periodic checks following the manufacturer’s maintenance plan. It is advisable to have spare battery packs to ensure the continued operation of the equipment in emergency services, ambulances and emergency units. For equipment fleets, volume orders or tenders, contact our technical-commercial department: for this product we will confirm compatibility, lead times and B2B conditions.