We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Original Philips Trilogy 100 battery | Ref. 1043570 – Li-ion 14.4 V 4 Ah for Trilogy 100, 200, 202 and T70 Cough Assist ventilators (Ref. Cahnos 88881034)

792,00 €

Original lithium-ion battery for Philips Trilogy ventilators: 14.4 V and 4 Ah (57.6 Wh), factory reference 1043570. Direct-fit replacement that restores the device’s standard battery life for continuous ventilation, intra-hospital transfers and operation without mains power in ICU, emergency departments and patient transport. Compatible with Trilogy 100, 200, 202 and T70 Cough Assist. Ref. Cahnos 88881034, price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881034

Description

1. Backup power for your Philips Trilogy ventilator

The original Philips Trilogy 100 battery (factory reference 1043570) is the standard accumulator with which the ventilator maintains ventilation when there is no nearby power socket: during an intra-hospital transfer, in an ambulance, on a ward without a stable mains supply or in the event of a power failure. With lithium-ion chemistry, 14.4 V and 4 Ah (57.6 Wh), it is the technical-commercial spare part that medical electronics departments need to keep in stock to restore the equipment’s original autonomy in a few minutes.

At Cahnos we work with institutional purchasing, ventilator fleets and tenders: this spare part is supplied as a unit, with the warranty and technical advice from our department to confirm compatibility with your batch of equipment before placing the order.

2. How this battery works in the ventilator

Ventilators in the Philips Trilogy family (Trilogy 100, 200, 202) and the cough assist unit T70 Cough Assist operate connected to the mains or powered by their internal rechargeable battery. While the equipment remains plugged in, the battery is automatically kept charged; when it is unplugged or in the event of a power cut, the battery takes over powering the compressor and the ventilation system without interrupting therapy.

Li-ion chemistry delivers a stable voltage of 14.4 V with 4 Ah capacity (57.6 Wh), high energy density, virtually no memory effect and integrated protection against overcharge and over-discharge. A degraded cell manifests as loss of autonomy, premature low-battery warnings or equipment alarms when it is disconnected from the mains; preventive replacement with this reference restores the ventilator to its factory performance in seconds and without tools.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) 88881034
Original manufacturer reference 1043570
Application Philips Trilogy 100, 200, 202 and T70 Cough Assist ventilators
Technology Li-Ion (lithium-ion), rechargeable
Nominal voltage 14.4 V
Nominal capacity 4 Ah (4000 mAh)
Nominal energy 57.6 Wh (14.4 V × 4 Ah)
Approximate weight 0.65 kg
Rechargeable Yes (automatic recharging with the device connected to the mains)
Installation Direct fit into the equipment compartment, without tools
Maintenance Maintenance-free
Presentation 1 unit
Recycling Management in accordance with WEEE regulations

Note: third-party spare parts for this platform are usually marketed in capacities of 5200 mAh (74.88 Wh) and 6800 mAh (97.92 Wh) with equivalent 14.4 V cells; the original factory reference is the 4 Ah one described in this datasheet.

4. Equivalences and Cross-References

The official manufacturer reference is 1043570, corresponding to the internal battery of the Trilogy platform (Trilogy 100 Breathe, Trilogy 100, Trilogy 200/202 and T70 Cough Assist). In the compatibility tables of specialised biomedical distribution, the alternative OEM codes M3969, 1043670, 1055804 and 1113780 consistently appear for this same pack, as does the code 88881034 itself in the platform’s replacement listings. There is no equivalence table validated by the manufacturer (Philips/Respironics) that authorises third-party batteries; cross-references from other manufacturers are limited to the same product category and must always be checked against the label of the removed pack and with our technical department before use in a tender.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Philips (original manufacturer) Internal battery for the Trilogy platform (Trilogy 100 Breathe / Trilogy 100 / Trilogy 200 / Trilogy 202 / T70 Cough Assist) 1043570 Exact reference equivalence (same manufacturer) Original factory reference: Li-ion, 14.4 V, 4 Ah (57.6 Wh), rechargeable. This is the reference reproduced by this spare part; check the label of the removed pack.
Philips (original manufacturer) Internal battery for the Trilogy platform M3969 Exact reference equivalence (same manufacturer) OEM alternative consistently cited as a replacement for the 1043570 in the compatibility tables of specialised biomedical distribution.
Philips (original manufacturer) Internal battery for the Trilogy platform 1043670 / 1055804 / 1113780 Exact reference equivalence (same manufacturer) Alternative part numbers for the same pack cited in those tables; same chemistry and voltage. Confirm the reference printed on the batch label.
Cameron Sino (replacement) Replacement battery for Philips Trilogy 100 / BiPAP A30 / A40 / T70 ventilator MED-CS-PHT100MX / MED-CS-PHT100MD Comparable by category (not interchangeable 1:1) Li-ion 14.4 V in capacities of 6800 mAh (97.92 Wh) and 5200 mAh (74.88 Wh); dimensions 153.3 × 44.0 × 58.0 mm. Replaces the 1043570 and other OEMs according to the replacement manufacturer’s datasheet; capacity different from the original, verify connector, seating and equipment self-test before replacing.

There is no equivalence table validated by the manufacturer (Philips) that officially cross-references the 1043570 with third-party batteries; the replacement codes cited come from replacement battery manufacturers and from compatibility tables in specialised distribution and must be checked with the technical department before use in a tender or replacement of an in-service device.

5. Selection tips and variants of interest

Confirm the exact model before ordering: this battery corresponds to the Philips Trilogy 100 (Breathe), Trilogy 200, Trilogy 202, T70 Cough Assist ventilators and equipment on the same platform (BiPAP A30/A40, CoughAssist E70). Always verify the reference stamped on the label of the removed battery (1043570, M3969, 1043670, 1055804 or 1113780) and the ventilator model.

Do not confuse Philips ventilator families: the Philips Respironics V60 uses the 11 Ah battery (reference 1076374, available at Cahnos as 88881344), a pack of different capacity and platform; neither battery is interchangeable with the other.

Replace when signs of wear appear: clearly reduced autonomy or low-battery warnings a few hours after charging indicate the end of the accumulator’s useful life; in normal clinical use the recommended practice is preventive renewal every 2-3 years. After installation, connect the ventilator to the mains and allow a full charge cycle to complete before a prolonged session in battery mode.

Storage: if the equipment is to remain unused for a long time, keep the battery in a cool, dry place with a partial charge and recharge it periodically to prevent degradation of the Li-ion chemistry. Take the exhausted pack to a collection point in accordance with WEEE regulations; never dispose of it in the general waste container.

For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department stating the model, serial number and reference of the fitted battery; we will confirm compatibility and offer you special conditions for volume.

Additional information

Product type

Replacement (spare) battery for medical ventilator

Manufacturer reference

1043570 (Philips/Respironics Trilogy platform)

Alternative OEM references

M3969, 1043670, 1055804, 1113780

Technology

Li-ion (lithium-ion), rechargeable

Nominal voltage

14.4 V

Nominal capacity

4 Ah (4000 mAh)

Nominal energy

57.6 Wh

Weight

Approx. 0.65 kg

Compatibility

Philips Trilogy 100 (Breathe), Trilogy 200, Trilogy 202 and T70 Cough Assist ventilators; associated BiPAP A30/A40 and CoughAssist E70 platform

Rechargeable

Yes (automatic recharging with the device connected to the mains)

Installation

Direct fit into the equipment compartment, without tools

Maintenance

Maintenance-free

Recycling

RAEE/WEEE

Intended use

Mechanical ventilation and respiratory support in ICU, emergency departments, medical transport and home ventilation

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Original Philips Trilogy 100 battery | Ref. 1043570 – Li-ion 14.4 V 4 Ah for Trilogy 100, 200, 202 and T70 Cough Assist ventilators (Ref. Cahnos 88881034)”

Your email address will not be published. Required fields are marked *