Description
1. Reliable backup power for your Hamilton ventilator
At Cahnos we offer the 14.4 V and 6.6 Ah (95 Wh) lithium-ion battery for Hamilton Medical C2, C3, C6 and S1 series medical ventilators, corresponding to the original manufacturer reference 369106 (Ref. Cahnos 88889247). It is the battery with which these ventilators maintain ventilation when there is no nearby power outlet: during an intra-hospital transfer, in emergency departments, in medical transport or in the event of a power supply failure. With Li-Ion chemistry, high energy density and automatic recharging in the equipment itself, it is the spare part that medical electronics services and hospital purchasing departments need to keep in stock to restore the ventilator to its original autonomy in a few minutes.
2. How this battery works in the ventilator
The ventilators in the Hamilton C2, C3, C6 and S1 family operate connected to the mains or powered by their internal rechargeable battery. While the equipment remains plugged in, the battery is automatically kept charged; when it is disconnected or in the event of a power cut, the battery takes over the power supply to the ventilation system without interrupting therapy and the equipment monitor displays the remaining autonomy. The Li-Ion chemistry delivers a stable voltage of 14.4 V with 6.6 Ah capacity (≈ 95 Wh), virtually no memory effect and integrated protection against overcharge and over-discharge. A degraded cell manifests itself as loss of autonomy, premature low-battery warnings or equipment alarms when disconnected from the mains; preventive replacement with this reference restores the ventilator to its factory performance with a direct fit in the original compartment, without tools or adaptations.
3. Technical Specifications
Data cross-checked against the original manufacturer reference 369106 and technical documentation from specialised biomedical distribution (OSI Batteries) and spare parts platforms.
| Parameter | Specification |
| Reference Cahnos (SKU) | 88889247 |
| Original manufacturer reference | Hamilton Medical 369106 (commercial numbering of the same pack: MSP369106) |
| Equipment manufacturer | Hamilton Medical |
| Application | Hamilton Medical C2, C3, C6 and S1 ventilators |
| Technology / Chemistry | Li-Ion (lithium-ion), rechargeable |
| Nominal voltage | 14.4 V |
| Nominal capacity | 6.6 Ah (6,600 mAh) |
| Nominal energy | ≈ 95 Wh (14.4 V × 6.6 Ah) |
| Pack dimensions | 167.2 × 107.0 × 21.0 mm |
| Approximate weight | 0.590 kg |
| Recharge | Automatic, integrated in the ventilator when connected to the mains |
| Installation | Direct replacement in the equipment compartment, without tools |
| Presentation | 1 unit |
| Recycling | Manage in accordance with WEEE regulations |
4. Equivalences and Cross-References
Reference 369106 is the original factory battery that this replacement reproduces, confirmed in official Hamilton Medical accessory catalogues and in specialised biomedical distribution. Reference 88889247 is the catalogue’s own coding from Cahnos; it is not an additional OEM code. Hamilton Medical does not publish an official equivalence table authorising third-party batteries for this pack; the cross-references indicated below share chemistry, voltage and functionality, and must be validated field by field (voltage, capacity, dimensions and connector) against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Hamilton Medical (original manufacturer) | Internal battery platform C2 / C3 / C6 / S1 (Li-Ion 14.4 V) | 369106 | Exact reference equivalence (same manufacturer) | Original factory reference: rechargeable Li-Ion, 14.4 V, 6.6 Ah (≈ 95 Wh). This is the reference that this replacement reproduces; verify the label on the removed pack. |
| Hamilton Medical (original manufacturer) | Internal battery platform C2 / C3 (Li-Ion 14.4 V) | MSP369106 | Exact reference equivalence (same manufacturer) | Commercial numbering of the same battery, consistently cited in specialised biomedical distribution (OSI Batteries, PartsSource) as a replacement for 369106; same chemistry and voltage. |
| OSI Batteries (Unipower) | Biomedical battery for Hamilton C2 / C3 ventilators | B12105 | Comparable by category (not interchangeable 1:1) | Li-Ion 14.4 V / 6.8 Ah; replaces 369106 according to the replacement manufacturer’s data sheet. Slightly higher capacity (6.8 Ah vs 6.6 Ah); validate connector, seating and equipment self-test. |
| Platform spare parts (Batterytype / DP Battery) | Replacement battery for Hamilton C2 / C3 / C6 / S1 | HA7494NOV_Oth / HAM22NO1548_Oth | Comparable by category (not interchangeable 1:1) | Li-Ion 14.4 V / 6.6 Ah (≈ 95 Wh), dimensions 167.2 × 107.0 × 21.0 mm, consistently cited on replacement platforms. Replacement manufacturer’s codings; confirm connector and charging electronics. |
There is no equivalence table validated by the manufacturer (Hamilton Medical) that cross-references 369106 with third-party batteries on a 1:1 basis; the cross-references indicated come from the replacement manufacturer and specialised biomedical distribution and must be checked with our technical department before use in tendering or replacement of equipment in service.
5. Selection tips and variants of interest
- Confirm the exact model of the equipment: this 14.4 V / 6.6 Ah battery corresponds to the Hamilton Medical C2, C3, C6 and S1 ventilators. Verify the reference printed on the label of the removed battery (369106 or MSP369106) before ordering.
- Do not confuse Hamilton ventilator families: the T1, C1 and MR1 series use a 10.8 V / 6.6 Ah Li-Ion battery (reference 369108, Ref. Cahnos 88881134), and the Hamilton Raphael ventilator fits a sealed lead-acid cell of 12 V / 2.3 Ah (Ref. Cahnos 88889715). None of these batteries is interchangeable with that of the C2/C3/C6/S1 without technical validation.
- Replace upon signs of wear: clearly reduced battery life or low-battery warnings within a few hours of charging indicate the end of the battery’s useful life; in normal clinical use, the recommended preventive replacement practice is every 2-3 years. After installation, connect the ventilator to the mains and allow a full charge cycle to complete before a prolonged session in battery mode.
- Storage: if the equipment is to remain unused for a long time, keep the battery in a cool, dry place with a partial charge and recharge it periodically to prevent degradation of the Li-Ion chemistry. Deliver the depleted pack to a collection point in accordance with WEEE regulations; never dispose of it in the general waste container.
- Institutional orders: for consortia, tenders or continuous supply contracts, contact our technical-commercial department stating the model, serial number and reference of the fitted battery; we will confirm compatibility and offer special volume conditions.