GE Datex Aestiva 7000 / 7700 SLA 12V 2.3Ah Battery – Replaces Ref. 1503-3045-000 | Respiration and Ventilation | Ref. 88888128

25,60 €

Replacement 12 V 2.3 Ah sealed lead-acid (SLA) battery for the GE Datex Aestiva 7000 and Aestiva 7700 anaesthesia systems with ventilator, replacing original reference 1503-3045-000 (code Cahnos 88888128). Rechargeable, sealed and maintenance-free battery, designed to ensure continuity of ventilation and monitoring during in-hospital transfers, power cuts or critical situations in the operating theatre and ICU. Nominal energy of 27.6 Wh and approximate weight of 1.125 kg. Direct replacement in the original compartment; confirm the reference stamped on the fitted battery before finalising the order.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888128

Description

1. Reliable backup power for your GE Datex anaesthesia system

At Cahnos we offer the replacement sealed lead-acid (SLA) battery, 12 V and 2.3 Ah, for the anaesthesia systems with ventilator GE Datex Aestiva 7000 and Aestiva 7700 (Ref. Cahnos 88888128). This is the replacement that substitutes the original part 1503-3045-000 and keeps your equipment operational when no mains power is available: intrahospital transfers, operating theatre preparation, power cuts or any interruption in which ventilation cannot be paused. It is the ideal solution for anaesthesia departments, operating theatres, ICUs and medical electronics maintenance programmes, with a very competitive price-performance ratio compared with the original part without compromising the electrical performance required by the equipment.

2. How this battery works in the equipment

The GE Datex Aestiva 7000 and Aestiva 7700 systems integrate an anaesthesia ventilator that incorporates an internal sealed lead-acid (SLA/VRLA) battery as a backup power source. While the trolley remains connected to the mains supply, the accumulator is kept on float charge; if the supply fails or the equipment is moved to transfer the patient, the battery automatically takes over powering the control electronics, monitoring and ventilator without interrupting ventilation. SLA chemistry is completely sealed, maintenance-free, does not leak electrolyte and can operate in different positions, characteristics required by equipment that operates continuously in a hospital environment. With a nominal capacity of 2.3 Ah and a voltage of 12 V, it delivers a theoretical energy of 27.6 Wh. When the autonomy is appreciably reduced or the equipment warns of low battery prematurely, it is time to replace the cell with this reference.

3. Technical Specifications

Data cross-checked against the product data sheet, the GE Healthcare parts catalogue and authorised distribution sources for reference 1503-3045-000.

Parameter Specification
Reference Cahnos (SKU) 88888128
Original manufacturer reference 1503-3045-000 (GE Healthcare / Datex-Ohmeda; also listed as 1503-3045-000-S)
Battery type Sealed lead-acid (SLA/VRLA), rechargeable, maintenance-free
Nominal voltage 12 V
Nominal capacity 2.3 Ah (2,300 mAh)
Theoretical energy 27.6 Wh (12 V × 2.3 Ah)
Weight Approximately 1.125 kg
Indicative dimensions Approx. 178.9 × 66.3 × 35.3 mm according to authorised distribution (verify with the mounted part)
Connection Direct wiring with connectors (wire leads) according to specialised distribution; verify with the removed battery
Compatible equipment GE Datex Aestiva 7000 and Aestiva 7700 anaesthesia systems
Compatibility documented in distribution Aestiva 3000, Aestiva 5000, Aestiva/5, Aespire 7900, ARC Aestiva 7100, ARC Cap 5 / CardioCap 5 and Modulus SE (GE Healthcare / Datex-Ohmeda)
Recharge Automatic with the equipment connected to the mains
Recycling Management in accordance with WEEE regulations

4. Equivalences and Cross-References

Verification note: the original reference 1503-3045-000 appears in the official GE Healthcare parts catalogue as a 12 V rechargeable battery for anaesthesia machines, and specialised distribution (PartsSource) documents it as a sealed lead-acid cell, 12 V / 2.2 Ah, with wiring to connectors. The published capacity for this part number ranges from 2.2 Ah to 2.9 Ah depending on the cell version (2.3 Ah in this data sheet). GE Healthcare / Datex-Ohmeda does not publish an official equivalence table with third-party batteries; the following cross-references share SLA chemistry and 12 V voltage and must be validated field by field before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GS Yuasa NP series (standby and cyclic) NP2.3-12 Comparable by category (not interchangeable 1:1) Standard SLA cell, 12 V / 2.3 Ah, housing 178 × 34 × 64 mm, Faston 4.75 mm (F1) terminal, maintenance-free. Same cell family documented for 12 V breathing and ventilation equipment. Verified in official GS Yuasa datasheet; check connector and compartment housing.
GS Yuasa NP series (standby) NP2.1-12 Comparable by category (not interchangeable 1:1) 12 V / 2.1 Ah nominal (20 h rate), same housing and Faston F1 terminal. Capacity slightly lower than that of this data sheet; verify that the charging electronics and the equipment’s low-battery thresholds accept it.
Leoch LP series (general use) LP12-2.3 Comparable by category (not interchangeable 1:1) SLA/VRLA battery, 12 V / 2.3 Ah, cited in distributor data sheets as a cross-reference for 12 V / 2.3 Ah medical equipment. Verify terminals and dimensions before installation.
R&D Batteries Replacement for OEM part 1503-3045-000 5899 Comparable by category (not interchangeable 1:1) Third-party 12 V SLA replacement documented by its manufacturer for Aestiva/5, Aestiva 3000, Aestiva 5000 and Aespire 7900 with part number 1503-3045-000. Published capacity of 2.3 Ah (2.6–2.9 Ah in other versions); verify connector and fit.
OSI Batteries (Unipower) Biomedical repackager for the 1503-3045-000 family B11102 Not verified Repackager code consistently cited alongside 1503-3045-000, 5899 and OM11124 in multiple independent sources. No official technical data sheet from the pack manufacturer verified in this review; confirm with the replacement part manufacturer before use.

There is no equivalence table validated by the manufacturer (GE Healthcare / Datex-Ohmeda) cross-referencing this part number with third-party batteries; the cross-references indicated share chemistry (SLA/VRLA) and voltage (12 V), but 1:1 replacement must be validated field by field: voltage, capacity, dimensions, connector type and terminal orientation against the specific unit. Consult the technical department at Cahnos before use in tenders.

5. Selection tips and variants of interest

  • Identify the exact equipment: this 12 V / 2.3 Ah battery is the one indicated for GE Datex Aestiva 7000 and Aestiva 7700 systems. Do not confuse it with the one for the Aestiva 7100, which uses a 6 V / 4 Ah cell (Ref. Cahnos 88888456), nor with the one for the Datex Ohmeda Excel 7800, 4.8 V Ni-Cd. Always check the label of the installed battery.
  • Verify the marked reference: if the removed battery shows the code 1503-3045-000 (or 1503-3045-000-S), it is the original part that this replacement substitutes; contact our technical-commercial department if you have any doubts before placing the order.
  • Check the compartment and connector: review the connection type (direct wiring with connectors) and the dimensions against the removed part; do not force the installation of a cell with different terminals or height without technical validation.
  • After replacement: leave the equipment connected to the mains to complete a charge cycle and carry out an autonomy test before returning it to service; the equipment electronics recalibrate the low-battery thresholds after the first full cycle.
  • Storage: keep the battery in a dry place, at room temperature and with periodic charges if the equipment remains unused, to extend its service life. At the end of its service life, dispose of it at a WEEE collection point.
  • Variants of the same family at Cahnos: 6 V / 4 Ah battery for GE Datex Aestiva 7100 (Ref. 88888456), 12 V / 2.3 Ah battery for Hamilton Raphael ventilator (Ref. 88889715) and Yuasa 12 V cells in 2.1/2.3 Ah format (Refs. 33101010 / 33101011). Do not interchange these references between models.
  • Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial team stating the model, serial number and reference of the fitted battery; we will confirm compatibility before finalising the order.

Additional information

Manufacturer reference

1503-3045-000 (GE Healthcare / Datex-Ohmeda; also 1503-3045-000-S)

Technology

Sealed lead-acid (SLA/VRLA), rechargeable, maintenance-free

Nominal voltage

12 V

Nominal capacity

2.3 Ah (2,300 mAh)

Theoretical energy

27.6 Wh (12 V × 2.3 Ah)

Weight

Approximately 1.125 kg

Indicative dimensions

Approx. 178.9 × 66.3 × 35.3 mm (according to authorised distribution; verify with the mounted part)

Connection

Direct wiring with connectors (wire leads) according to specialised distribution

Compatibility

GE Datex Aestiva 7000 and Aestiva 7700 anaesthesia systems

Rechargeable

Yes; automatic recharging when the equipment is connected to the mains

Intended use

Ventilators and anaesthesia systems with ventilator in operating theatre, ICU and intra-hospital transport