We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Ni-MH battery 12V 2.5Ah for Dräger Babylog Carina ventilator | Replaces original ref. 5703153 (5703153-05/-08) | Ref. Cahnos 88889296

288,00 €

Replacement Ni-MH 12V 2.5Ah battery for the Dräger Babylog Carina ventilator, compatible with the manufacturer’s original reference 5703153 (variants 5703153-04/-05/-07/-08). Designed to ensure continuity of neonatal and infant ventilation during intra-hospital transfers, patient mobilisation or mains power interruptions, with automatic recharging while the equipment remains connected to the mains. Nickel-metal hydride chemistry, nominal voltage 12 V, capacity 2.5 Ah and compact dimensions of 114.4 × 93.3 × 24.5 mm. Direct replacement of the original accumulator without modifying the equipment. Ideal solution for neonatology units, NICUs, critical care services, medical transport and medical electronics maintenance programmes, with a very competitive quality-price ratio compared with the original part. Ref. Cahnos 88889296.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88889296

Description

1. Reliable power for your Dräger Babylog Carina ventilator

At Cahnos we offer the replacement battery for the Dräger Babylog Carina neonatal and infant ventilator (Ref. Cahnos 88889296), which replaces the manufacturer’s original reference 5703153 in its documented variants 5703153-04, -05, -07 and -08. This 12 V, 2.5 Ah nickel-metal hydride (Ni-MH) accumulator restores the equipment’s full autonomy so that assisted ventilation is not interrupted during intra-hospital transfers, patient mobilisation or power supply cuts. It is the spare part that returns your ventilator to full operability with an excellent quality-price ratio, without compromising the reliability required for life support. Ideal solution for neonatology services, neonatal intensive care units (NICU), medical transport and medical electronics departments.

2. How this battery works in your equipment

The Dräger Babylog Carina is a ventilator designed for invasive and non-invasive ventilation (NIV) of neonates and infants, commonly used in NICUs and neonatal transport. When the equipment is disconnected from the mains, its internal power supply module relies on the accumulator to sustain the control electronics, ventilation, monitoring and safety alarms without interruption.

This pack uses nickel-metal hydride (Ni-MH) chemistry, which provides stable current delivery, good energy density and robust behaviour against the memory effect compared with classic nickel-cadmium chemistries. The accumulator is rechargeable: while the ventilator remains connected to the mains, the equipment itself keeps the battery charged automatically. When the autonomy is noticeably reduced or the ventilator warns of low battery prematurely, it is time to replace the pack with this reference. Replacement is carried out in the equipment’s original compartment, without the need to modify the device.

3. Technical Specifications

Parameter Specification
Application Dräger Babylog Carina ventilator (neonatal and infant ventilation, invasive and non-invasive)
Original manufacturer reference 5703153 (documented variants: 5703153-04, -05, -07, -08)
Technology Nickel-Metal Hydride (Ni-MH), rechargeable
Nominal voltage 12 V
Nominal capacity 2.5 Ah (2500 mAh)
Theoretical energy 30 Wh (12 V × 2.5 Ah)
Weight Approximately 0.590 kg
Dimensions 114.4 × 93.3 × 24.5 mm
Rechargeable Yes; automatic recharging when the equipment is connected to the mains
Installation Direct replacement in the battery compartment, no modifications required
Device manufacturer Dräger
SKU Cahnos 88889296

Technical data taken from the product data sheet and cross-checked against specialised technical distribution sources. Always verify the label of the battery fitted in your equipment before placing the order.

4. Equivalences and Cross-References

Reference 5703153 is consistently documented in the spare parts market as the original battery for the Dräger Carina ventilator (NIV ventilator), in its variants 5703153-04, -05, -07 and -08, with Ni-MH chemistry, 12 V and 2.5 Ah. There is no equivalence table validated by Dräger itself that authorises third-party batteries for this reference; the alternatives indicated below come from independent biomedical spare parts manufacturers and distributors and have been cross-checked against their product data sheets. Before replacing, always confirm chemistry, voltage, capacity, connector and dimensions against the removed part.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Dräger (device manufacturer) Carina ventilator internal battery (NIV ventilator) 5703153 (variants -04 / -05 / -07 / -08) Exact reference equivalence (same manufacturer) Original Ni-MH 12 V / 2.5 Ah battery; this is the reference that our spare part replaces. Confirm the variant stamped on the fitted battery.
OSI Batteries (biomedical spare part) Draeger Carina NIV Ventilator Battery OM11759 Comparable by category (not interchangeable 1:1) Ni-MH 12 V / 2.5 Ah; spare part that replaces the original part 5703153-05. Verify connector and housing before replacing.
Partopia Medical (biomedical spare part) Carina NIV Ventilator Battery PM0329 Comparable by category (not interchangeable 1:1) Ni-MH 12 V / 2.5 Ah; OEM reference document 5703153-05. Confirm dimensions, connector and equipment charging protocol.

Furthermore, the cross-reference codes 02271 and 8415290-08 frequently appear in the spare parts market associated with this same accumulator; they have not been verified against the official data sheet of the spare part manufacturer —and 8415290-08 corresponds in other listings to 24 V batteries of the Babylog family— so they should be treated as indicative references pending confirmation with the supplier before use. There is no equivalence table validated by the manufacturer (Dräger) that cross-references this reference with third-party brands; consult the technical department of Cahnos before using in tenders.

5. Selection tips and variants of interest

  • Identify the exact reference of your battery: confirm the number stamped on the fitted battery (5703153, 5703153-05, 5703153-08 or another) before ordering the spare part. This battery corresponds to the Dräger Babylog Carina ventilator; do not confuse it with the Babylog VN5000 battery (24 V), which is not interchangeable.
  • Verify voltage, chemistry and connector: the Carina uses a 12 V Ni-MH pack with a specific connector. Do not replace with batteries of another voltage or chemistry even if the housing looks similar, unless validated by the technical service.
  • Ni-MH maintenance: avoid repeated deep discharges and keep the accumulator charged if the equipment is to remain unused for several days, to extend its service life. Performance depends on the cycle history and ambient temperature.
  • After installation: leave the ventilator connected to the mains to complete the charge and carry out an autonomy test before returning the equipment to clinical service.
  • Recycling: dispose of the exhausted battery at an authorised collection point in accordance with WEEE regulations.
  • Institutional orders: for tenders, continuous supply contracts or bidding processes, contact the technical-commercial department of Cahnos to validate exact compatibility with your equipment fleet and obtain a formalised quotation under B2B conditions.

Additional information

Technology

Nickel-Metal Hydride (Ni-MH) rechargeable

Nominal voltage

12 V

Capacity

3 Ah (3000 mAh)

Energy

36 Wh

Manufacturer reference

5703153, 5703153-04, 5703153-05, 02271, OM11759

Compatibility

Dräger Babylog Carina ventilator (neonatal and infant ventilation, invasive and non-invasive)

Weight

Approximately 0.590 kg

Dimensions

114.4 × 93.3 × 24.5 mm

Use

Neonatal and infant ventilation in NICU, neonatology, critical care and medical transport

Device manufacturer

Dräger

Rechargeable

Yes; automatic recharging when the equipment is connected to the mains

Original manufacturer reference

5703153 (variants 5703153-04, -05, -07, -08)

Nominal capacity

2.5 Ah (2500 mAh)

Theoretical energy

30 Wh (12 V × 2.5 Ah)

Installation

Direct replacement in the battery compartment

Recycling

WEEE

Alimentacion

Rechargeable battery

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Ni-MH battery 12V 2.5Ah for Dräger Babylog Carina ventilator | Replaces original ref. 5703153 (5703153-05/-08) | Ref. Cahnos 88889296”

Your email address will not be published. Required fields are marked *