Sealed lead battery 24 V 7 Ah for Puritan Bennett 840 (PB840/NPB840) ventilator by Medtronic/Covidien | Replaces ref. 4-070523 | Ref. 88888405

48,00 €

Sealed lead-acid battery (SLA/VRLA) 24 V and 7 Ah for the Medtronic/Covidien Puritan Bennett 840 (PB840/NPB840) ventilator, manufactured to replace the original reference 4-070523/4-070523-SP. It provides approximately 2 hours of autonomy to the ventilator’s auxiliary power supply system, ensuring uninterrupted critical ventilation in the event of mains power failure or during intra-hospital transport. Reference Cahnos 88888405.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888405

Description

Replacement battery for Puritan Bennett 840 ventilator

This sealed lead-acid (SLA/VRLA) battery, 24 V and 7 Ah, is the ideal replacement for the Medtronic/Covidien Puritan Bennett 840 ventilator (PB840 or NPB840), one of the most widely used ICU and transport ventilators in European hospitals. It replaces the original manufacturer reference 4-070523 / 4-070523-SP and restores the autonomy of the equipment’s auxiliary power supply system, so that mechanical ventilation is maintained without interruption during a mains failure, a transfer or a scheduled maintenance stop.

An aged battery is the most frequent cause of power supply alarms in these ventilators. Replacing it in time prevents the equipment from becoming inoperative at the critical moment and extends the service life of the device’s internal power supply.

What role does this battery play in the PB840?

The Puritan Bennett 840 incorporates an auxiliary power supply known as the BPS system (Battery Power Supply), which keeps the ventilator running when the alternating current is interrupted. The internal battery is a rechargeable element subjected to continuous charge and discharge cycles, so its capacity degrades over time and must be replaced preventively following the maintenance plan in the service manual.

  • Provides power backup to the ventilator during mains failures and intra-hospital transfers.
  • With this battery (24 V, 7 Ah), an approximate autonomy of 2 hours is recovered, the standard configuration of the 2-hour BPS system.
  • Replacement must be carried out by qualified biomedical technical staff according to the PB840 service manual (BPS system maintenance section, 8.18.3), then performing the ventilator self-test to verify correct operation.

Important technical clarification: the original reference 4-070523/4-070523-SP corresponds, according to the service manual and official manufacturer sources, to a sealed lead-acid (SLA/VRLA) battery of 24 V and 7 Ah with approximately 2 hours of autonomy. The data in this datasheet have been cross-checked against these sources to avoid specification errors.

Technical specifications

Characteristic Specification
Battery type Sealed lead-acid (SLA/VRLA) rechargeable
Nominal voltage 24 V
Nominal capacity 7 Ah
Approximate autonomy 2 hours (internal battery of the BPS system)
Original manufacturer reference 4-070523 / 4-070523-SP
Compatible device Medtronic/Covidien Puritan Bennett 840 ventilator (PB840 / NPB840); Puritan Bennett 700/800 ecosystem to be verified by service manual
Use Backup power for critical ventilation (ICU, emergency, transport)
SKU Cahnos 88888405

Equivalences and cross-references

Manufacturer / Brand Family / Model Code / Reference Equivalence Level Technical Differences / Remarks
Medtronic / Covidien (Puritan Bennett) PB840 2-hour internal battery 4-070523 / 4-070523-SP Exact reference equivalence (original reference replaced by this unit) Original SLA/VRLA battery, 24 V and 7 Ah, for the PB840 BPS system; this Cahnos unit replaces it with equivalent performance.
Medtronic / Covidien (Puritan Bennett) PB840 4-hour internal battery 10025355 Comparable by category (not interchangeable 1:1) Original higher-capacity variant (24 V, 18 Ah, 4-hour autonomy) for the same ventilator; same function but different capacity, weight and dimensions.
OSI Batteries (USA) Biomedical Battery PB840 B11218 Comparable by category (not interchangeable 1:1) Aftermarket replacement of 24 V and 7 Ah SLA/VRLA for the 4-070523; independent manufacture; verify harness, connector and trolley housing before mounting.
R&D Batteries PB840 2 Hour Battery Replacement 5110 Comparable by category (not interchangeable 1:1) Aftermarket replacement 24 V and 7 Ah SLA for the 4-070523-SP; not approved by the device manufacturer; validate with ventilator self-test.
Medical Batteries (Canada) SLA battery with fuse and harness BD35110 Comparable by category (not interchangeable 1:1) 24 V and 7 Ah SLA; replaces 4-070523-SP; includes fuse and harness; Health Canada licence; verify connector compatibility.
Partopia Medical PB840 Ventilator Battery PM0139 Comparable by category (not interchangeable 1:1) Replacement battery 24 V and 7 Ah SLA/VRLA for PB840; independent manufacture; confirm installation with technical staff.

There is no equivalence table validated by the manufacturer for this family; consult the technical department before using in tenders. Note: the code 10097559 circulating associated with the PB840 family corresponds to the ventilator’s galvanometric oxygen sensor, not the battery; do not confuse when processing spare parts orders.

Selection tips and variants of interest

  • Confirm the exact model of your ventilator (PB840, PB740, PB760) and the BPS system configuration (2 hours or 4 hours) before ordering the spare part; the reference 4-070523/4-070523-SP corresponds to the standard 2-hour configuration.
  • If your facility needs longer autonomy for long transfers or evacuations, consider the original 4-hour variant (ref. 10025355, 24 V and 18 Ah), comparable by category but not interchangeable 1:1 with this unit.
  • Schedule preventive replacement according to the maintenance plan in the service manual and record the installation date; SLA batteries progressively degrade their capacity with charge cycles.
  • After installation, run the ventilator self-test to verify the battery status and the absence of power supply alarms before returning the equipment to service.
  • Manage the used battery as lead-acid waste in accordance with current regulations on waste electrical and electronic equipment (WEEE).

Additional information

Battery type

Sealed lead-acid (SLA/VRLA) rechargeable

Nominal voltage

24 V

Capacity

7 Ah

Battery life

Approximately 2 hours

Manufacturer reference

4-070523 / 4-070523-SP

Compatibility

Medtronic/Covidien Puritan Bennett 840 ventilator (PB840/NPB840); verify 700/800 ecosystem with service manual

Application

Backup power for critical ventilation (ICU, emergency, transport)