We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Ni-MH Battery 9.6 V / 1.7 Ah for TAEMA Osiris 3 Ventilator (Air Liquide) | Replacement KY564600 / PS024 · Ref. Cahnos 88888630

48,00 €

Rechargeable nickel-metal hydride (Ni-MH) battery of 9.6 V and 1.7 Ah for the TAEMA Osiris 3 emergency and transport ventilator (Air Liquide), a direct replacement for the original part numbers KY564600 / PS024. With AA-format cells, compact dimensions of 56×28×52 mm and weighing only 208 g, it guarantees ventilator autonomy during mains power failures in emergency care, intra-hospital transport, ICU and post-anaesthesia care units. European assembly with Saft cells and CE declaration of conformity from the replacement manufacturer; compatibility verified with the Osiris 3 platform (Air Liquide/TAEMA respiratory care and ventilation). Ref. Cahnos 88888630.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888630

Description

1. Replacement battery for TAEMA Osiris 3 respirator

Keep your TAEMA Osiris 3 respirator always operational with this 9.6 V, 1.7 Ah nickel-metal hydride (Ni-MH) replacement battery, specifically for the Air Liquide respiratory and ventilation family. It is a reliable and economical spare part that directly replaces the original reference KY564600 (also coded as PS024 in specialist distribution) and guarantees continuity of care in emergencies, pre- and intrahospital transport, critical care units and postoperative wards. A practical solution for maintenance services, biomedical engineering and hospital purchasing departments that need standardised and traceable spare parts, with CE declaration of conformity and Saft cells of European assembly.

2. How this battery works in your ventilation equipment

The Osiris 3 is a compact and portable medical ventilator from TAEMA (hospital subsidiary of the Air Liquide group), designed for emergency ventilation and transport of adult and paediatric patients, both in prehospital settings and in intensive care and postoperative recovery. The equipment allows volume-controlled ventilation with pure oxygen or a mixture of ambient air and oxygen, with volume monitoring and audible and visual alarm system. The internal rechargeable battery ensures continuity of ventilation when the respirator is not connected to the mains: the pack recharges automatically while the equipment remains plugged into its power supply. For stable and safe operation in critical situations, it is essential that the battery maintains the correct nominal voltage (9.6 V), the Ni-MH chemistry and the same type of connector and equipment compartment.

3. Technical Specifications

Characteristic Value
Reference Cahnos (SKU) 88888630
Original reference KY564600 (coded PS024 in distribution)
Application TAEMA Osiris 3 Respirator / Osiris 3 Ventilator (Air Liquide)
Device manufacturer Air Liquide (TAEMA)
Technology Nickel-Metal Hydride (Ni-MH)
Nominal voltage 9.6 V
Capacity 1.7 Ah (1700 mAh)
Energy 16.3 Wh approx.
Cells 8 cells of 1.2 V in series (AA format)
Dimensions 56 mm (L) x 28 mm (W) x 52 mm (H)
Weight 0.208 kg approx.
Type Rechargeable
Presentation Unit

4. Equivalences and Cross-References

Code verification: reference KY564600 consistently appears as the original reference for the battery pack of the TAEMA Osiris 3 respirator in the technical data sheet of the authorised distributor VLAD (document 88888630, Ni-MH 9.6 V / 1.7 Ah battery, Saft cells, Exalium Premium model, with CE declaration of conformity) and as equivalent coding PS024 in specialist distribution sources. The codes Cameron Sino CS-TRS300MD and CS-ART300MD have been cross-checked in the brand’s authorised distribution catalogues (EAN 4894128229353 for CS-TRS300MD). No registration in GUDID/FDA or EUDAMED is recorded for KY564600; treat this reference as catalogue data, not regulatory data.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Cameron Sino CS-TRS300MD (Taema Osiris 3 / PS024) CS-TRS300MD Comparable by category (not interchangeable 1:1) Replaces KY564600 / PS024; same voltage of 9.6 V, Ni-MH chemistry and compatibility with Osiris 3, but capacity of 2000 mAh (higher) and dimensions of 58.4 x 51.4 x 29.3 mm with weight of approx. 306 g vs 56 x 28 x 52 mm / 208 g. Verify the equipment’s charging electronics before replacing.
Cameron Sino MED-CS-ART300MD (Air Liquide Blease 5500 Osiris 3) CS-ART300MD Comparable by category (not interchangeable 1:1) Same Osiris 3 platform (Taema Respirator / Ventilator Osiris 3 and Blease 5500 Osiris 3); replaces YR109301 / YR109301031404. Ni-MH 9.6 V with 1500 mAh (lower capacity) and dimensions of 56.8 x 50.3 x 28.5 mm. Confirm connector and compartment of the equipment.
AolsteCell PS024 Medical Battery (Air Liquide KY564600) AOM10979 Not verified Commercial spare part advertised for KY564600 / PS024 on Osiris 3 (9.6 V, 2000 mAh, 8 declared cells); however, the distributor’s data sheet text mentions lithium-ion cells versus the Ni-MH chemistry declared in the table, and does not specify dimensions. Confirm chemistry, connector and dimensions with the manufacturer before replacement.

There is no equivalence table validated by the manufacturer (Air Liquide/TAEMA) for this reference; consult the technical department before use in tenders. Additionally, there are compatible spare parts for KY564600 on the market from the Exalium Premium range and from specialist distributors: check voltage, chemistry, capacity and connector in each technical data sheet before replacement. Commercial spare parts in this family are usually available between 1500 and 2000 mAh.

5. Selection tips and variants of interest

Always identify the exact model of your equipment: this 9.6 V / 1.7 Ah battery is the one indicated for the TAEMA Osiris 3 respirator. The battery for the Osiris 2 respirator (Ni-Cd, 9.6 V, 1 Ah; ref. KY50900, Ref. Cahnos 88888629) belongs to the same Osiris family but is not interchangeable with this unit without prior technical verification of the equipment.

Verify the voltage (9.6 V) and the connector type before replacing. Ni-MH batteries do not have the memory effect of Ni-Cd, but suffer from self-discharge when idle: keep the respirator connected to the mains when not in use to preserve the charge and perform full charge cycles periodically.

After installing a new pack, allow the Osiris 3 to complete its power-on self-test without interruption; in some cases the battery management system requires one or two complete charge-discharge cycles to accept the new cell and calibrate the autonomy indicator.

If you require greater autonomy, consider 2000 mAh Ni-MH replacement batteries only if the equipment’s charging electronics allow it; if in doubt, consult the technical service. For transport and emergency care equipment, it is recommended to keep a spare battery and check the low-battery indicator before each departure.

For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formal quotation.

Additional information

Manufacturer reference

KY564600 (also coded as PS024 in commercial spare parts)

Device manufacturer

Air Liquide (TAEMA)

Compatibility

TAEMA Osiris 3 Respirator / Osiris 3 Ventilator

Technology

Nickel-Metal Hydride (Ni-MH)

Nominal voltage

9.6 V

Capacity

1.7 Ah (1700 mAh)

Energy

16.3 Wh approx.

Cells

8 cells of 1.2 V in series (AA format)

Dimensions

56 x 28 x 52 mm

Weight

0.208 kg approx.

Product type

Rechargeable

Use

Emergency respirator, intrahospital transport, ICU and postoperative

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Ni-MH Battery 9.6 V / 1.7 Ah for TAEMA Osiris 3 Ventilator (Air Liquide) | Replacement KY564600 / PS024 · Ref. Cahnos 88888630”

Your email address will not be published. Required fields are marked *