Description
1. Original power for your Arjo Minstrel lift
Keep your Arjo Minstrel patient lift system operational with the original battery we supply under reference Cahnos 88888784, corresponding to the manufacturer’s reference TGT223. This rechargeable battery of 24 V and 5.5 Ah restores full autonomy to the equipment for lifting, verticalisation and patient transfer manoeuvres in hospitals, care homes and social-healthcare centres, without depending on the mains power supply.
It is the original spare part solution for maintenance services, biomedical engineering and purchasing departments that need a traceable, proven-quality replacement for their fleet of Arjo lifts, with the assurance provided by a component from the brand itself. Available with special conditions for consortia, tenders and maintenance contracts.
2. How this battery works in the lifting system
The Arjo Minstrel patient verticaliser/lift powers its lifting motor via an internal rechargeable battery when the equipment is not connected to the mains. When the battery life is noticeably reduced, the equipment warns of low battery prematurely or the lift becomes slow, it is time to replace the battery with this reference.
The pack delivers the nominal voltage of 24 V required by the motor from its internal cells. Replacement is carried out by removing the depleted battery from the compartment and installing the new one respecting the orientation and connector, without the need for tools or adaptations. After installation, a full charge is recommended before first use. The robust housing and protection against short circuits and overheating ensure safe operation in healthcare environments.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Application | Arjo Minstrel patient lift system (verticaliser), reference TGT223; also documented for Excelsior, Gemini and Minerva verticalisers according to authorised distribution |
| Original manufacturer reference | TGT223 (distribution alias SPL3024S) |
| Reference Cahnos (SKU) | 88888784 |
| Technology | Sealed lead-acid (SLA/VRLA AGM) according to the spare part’s technical data sheet; the historical commercial data sheet describes Ni-MH (check label) |
| Nominal voltage | 24 V |
| Capacity | 5.5 Ah |
| Theoretical energy | 132 Wh (24 V × 5.5 Ah) |
| Weight | ≈ 4.38 kg according to technical data sheet (historical commercial data sheet: ≈ 1.8 kg; check label) |
| Dimensions | 150 x 95 x 70 mm (commercial data sheet) |
| Device manufacturer | Arjo |
| Rechargeable | Yes; recharge with the lift charger |
| Installation | Direct replacement in the lift compartment, without tools |
| Presentation | 1 unit |
| Recycling | Manage in accordance with WEEE regulations |
Technical note: the historical commercial data sheet describes this battery as Ni-MH of approximately 1.8 kg with the indicated dimensions; however, the technical documentation of the spare part and specialised distribution catalogues identify the pack that replaces reference TGT223 as sealed lead-acid (SLA/VRLA AGM) of 24 V / 5.5 Ah with a weight close to 4.4 kg. Before replacing, check the label of the installed battery and the chemistry for which your equipment’s charger is adjusted.
4. Equivalences and Cross-References
The Arjo TGT223 reference (24 V / 5.5 Ah) has been cross-checked against biomedical battery manufacturers and specialised distribution catalogues. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the electrical platform and are classified as comparable by category, not 1:1 interchangeable, and must be validated field by field (voltage, chemistry, dimensions and connector) against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| MSP Medical | Battery Pack 24V/DC 5.5Ah for Arjo/Medibo patient lifts (replaces TGT.223) | MSP-A-MB-00100 (EAN 8719925310218) | Comparable by category (not interchangeable 1:1) | SLA/VRLA AGM 24 V / 5.4 Ah; designed for Arjo/Medibo Excelsior, Gemini and Minerva verticalisers/lifts; MDR compliant; same electrical platform (24 V) with slightly lower capacity (5.4 vs 5.5 Ah) and chemistry matching the technical documentation of the pack; check connector and dimensions. Confirmed in the spare part manufacturer’s data sheet. |
| ALCO / Direct Supply | Battery Pack 24V 5.5Ah for Arjo patient lifts | AL-26396 | Comparable by category (not interchangeable 1:1) | 24 V / 5.5 Ah for Arjo lifts, including Minstrel Single and Minstrel Double; corresponds to original reference NDA0200 (not TGT223); same voltage and capacity; verify fit, connector and chemistry on the specific unit. Confirmed in the distributor’s data sheet. |
There is no equivalence table validated by the manufacturer Arjo for this reference (TGT223); the cross-references indicated come from biomedical battery manufacturers and specialised distributors, so it is recommended to consult the technical department before use in tendering.
5. Selection tips and variants of interest
- Confirm the exact model of the equipment: this battery corresponds to Arjo reference TGT223 for the Minstrel system (alias SPL3024S in distribution). According to authorised distribution, the same pack is documented for Excelsior, Gemini and Minerva verticalisers.
- Verify the chemistry of the batch: check on the label whether the installed pack is sealed lead-acid (SLA/VRLA AGM) or Ni-MH and use the charger adjusted to that chemistry. Do not install a battery of another chemistry or voltage even if the connector might appear compatible.
- Replace upon signs of wear: clearly reduced battery life, premature low battery warnings or slow lifting indicate that the battery has reached the end of its service life (typically 2-3 years depending on intensity of use).
- Storage: if the lift is to remain unused for long periods, carry out a periodic recharge (every 2-3 months) and avoid deep discharges. At the end of its service life, dispose of the battery at a WEEE collection point; never discard it as municipal waste.
- Variants in our catalogue: you have the compatible version of this same reference (Ref. 88889873, 24 V / 5.5 Ah), the compatible Arjo NDA0100 battery (Ref. 88881140, 24 V / 4 Ah, also valid for Minstrel), the Arjo Sarita KTA0102 battery (Ref. 88881143, 24 V / 2.3 Ah), the Arjo Maxi Twin NEA0100 battery (Ref. 88881142 and 88888563, 12 V / 2.7 Ah) and the Arjo Tempo KPA0100 battery (Ref. 88881141 and 88888033, 12 V / 2.7 Ah). Do not interchange these references between models without technical validation.
- Institutional orders: for consortia, tenders or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility with your fleet of lifts and obtain a formalised quotation with special conditions by volume.





Reviews