We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Original Arjo Minstrel TGT223 Battery 24V 5.5Ah for Patient Lifting | Brand Replacement | Ref. 88888784

720,00 €

Original Arjo battery for the Minstrel patient lift system (reference TGT223, distribution alias SPL3024S). Rechargeable battery of 24 V and 5.5 Ah that restores the equipment’s full autonomy for patient lifting, verticalisation and transfer manoeuvres in hospitals, care homes and social healthcare centres, without relying on the mains electricity supply. Tool-free direct replacement in the lift compartment, and recharging via the equipment’s own charger. Original brand spare part, traceable, suitable for maintenance services, biomedical engineering and Arjo equipment fleets. Before replacing, check the label on the fitted battery and the chemistry for which your lift’s charger is set. Ref. Cahnos 88888784.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88888784

Description

1. Original power for your Arjo Minstrel lift

Keep your Arjo Minstrel patient lift system operational with the original battery we supply under reference Cahnos 88888784, corresponding to the manufacturer’s reference TGT223. This rechargeable battery of 24 V and 5.5 Ah restores full autonomy to the equipment for lifting, verticalisation and patient transfer manoeuvres in hospitals, care homes and social-healthcare centres, without depending on the mains power supply.

It is the original spare part solution for maintenance services, biomedical engineering and purchasing departments that need a traceable, proven-quality replacement for their fleet of Arjo lifts, with the assurance provided by a component from the brand itself. Available with special conditions for consortia, tenders and maintenance contracts.

2. How this battery works in the lifting system

The Arjo Minstrel patient verticaliser/lift powers its lifting motor via an internal rechargeable battery when the equipment is not connected to the mains. When the battery life is noticeably reduced, the equipment warns of low battery prematurely or the lift becomes slow, it is time to replace the battery with this reference.

The pack delivers the nominal voltage of 24 V required by the motor from its internal cells. Replacement is carried out by removing the depleted battery from the compartment and installing the new one respecting the orientation and connector, without the need for tools or adaptations. After installation, a full charge is recommended before first use. The robust housing and protection against short circuits and overheating ensure safe operation in healthcare environments.

3. Technical Specifications

Characteristic Specification
Application Arjo Minstrel patient lift system (verticaliser), reference TGT223; also documented for Excelsior, Gemini and Minerva verticalisers according to authorised distribution
Original manufacturer reference TGT223 (distribution alias SPL3024S)
Reference Cahnos (SKU) 88888784
Technology Sealed lead-acid (SLA/VRLA AGM) according to the spare part’s technical data sheet; the historical commercial data sheet describes Ni-MH (check label)
Nominal voltage 24 V
Capacity 5.5 Ah
Theoretical energy 132 Wh (24 V × 5.5 Ah)
Weight ≈ 4.38 kg according to technical data sheet (historical commercial data sheet: ≈ 1.8 kg; check label)
Dimensions 150 x 95 x 70 mm (commercial data sheet)
Device manufacturer Arjo
Rechargeable Yes; recharge with the lift charger
Installation Direct replacement in the lift compartment, without tools
Presentation 1 unit
Recycling Manage in accordance with WEEE regulations

Technical note: the historical commercial data sheet describes this battery as Ni-MH of approximately 1.8 kg with the indicated dimensions; however, the technical documentation of the spare part and specialised distribution catalogues identify the pack that replaces reference TGT223 as sealed lead-acid (SLA/VRLA AGM) of 24 V / 5.5 Ah with a weight close to 4.4 kg. Before replacing, check the label of the installed battery and the chemistry for which your equipment’s charger is adjusted.

4. Equivalences and Cross-References

The Arjo TGT223 reference (24 V / 5.5 Ah) has been cross-checked against biomedical battery manufacturers and specialised distribution catalogues. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the electrical platform and are classified as comparable by category, not 1:1 interchangeable, and must be validated field by field (voltage, chemistry, dimensions and connector) against the specific equipment before replacement.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
MSP Medical Battery Pack 24V/DC 5.5Ah for Arjo/Medibo patient lifts (replaces TGT.223) MSP-A-MB-00100 (EAN 8719925310218) Comparable by category (not interchangeable 1:1) SLA/VRLA AGM 24 V / 5.4 Ah; designed for Arjo/Medibo Excelsior, Gemini and Minerva verticalisers/lifts; MDR compliant; same electrical platform (24 V) with slightly lower capacity (5.4 vs 5.5 Ah) and chemistry matching the technical documentation of the pack; check connector and dimensions. Confirmed in the spare part manufacturer’s data sheet.
ALCO / Direct Supply Battery Pack 24V 5.5Ah for Arjo patient lifts AL-26396 Comparable by category (not interchangeable 1:1) 24 V / 5.5 Ah for Arjo lifts, including Minstrel Single and Minstrel Double; corresponds to original reference NDA0200 (not TGT223); same voltage and capacity; verify fit, connector and chemistry on the specific unit. Confirmed in the distributor’s data sheet.

There is no equivalence table validated by the manufacturer Arjo for this reference (TGT223); the cross-references indicated come from biomedical battery manufacturers and specialised distributors, so it is recommended to consult the technical department before use in tendering.

5. Selection tips and variants of interest

  • Confirm the exact model of the equipment: this battery corresponds to Arjo reference TGT223 for the Minstrel system (alias SPL3024S in distribution). According to authorised distribution, the same pack is documented for Excelsior, Gemini and Minerva verticalisers.
  • Verify the chemistry of the batch: check on the label whether the installed pack is sealed lead-acid (SLA/VRLA AGM) or Ni-MH and use the charger adjusted to that chemistry. Do not install a battery of another chemistry or voltage even if the connector might appear compatible.
  • Replace upon signs of wear: clearly reduced battery life, premature low battery warnings or slow lifting indicate that the battery has reached the end of its service life (typically 2-3 years depending on intensity of use).
  • Storage: if the lift is to remain unused for long periods, carry out a periodic recharge (every 2-3 months) and avoid deep discharges. At the end of its service life, dispose of the battery at a WEEE collection point; never discard it as municipal waste.
  • Variants in our catalogue: you have the compatible version of this same reference (Ref. 88889873, 24 V / 5.5 Ah), the compatible Arjo NDA0100 battery (Ref. 88881140, 24 V / 4 Ah, also valid for Minstrel), the Arjo Sarita KTA0102 battery (Ref. 88881143, 24 V / 2.3 Ah), the Arjo Maxi Twin NEA0100 battery (Ref. 88881142 and 88888563, 12 V / 2.7 Ah) and the Arjo Tempo KPA0100 battery (Ref. 88881141 and 88888033, 12 V / 2.7 Ah). Do not interchange these references between models without technical validation.
  • Institutional orders: for consortia, tenders or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility with your fleet of lifts and obtain a formalised quotation with special conditions by volume.

Additional information

Application

Patient lifting system (verticaliser) Arjo Minstrel, reference TGT223; also documented for Excelsior, Gemini and Minerva verticalisers according to authorised distribution

Manufacturer reference

TGT223 (distribution alias SPL3024S)

Technology

Sealed lead-acid (SLA/VRLA AGM) according to technical data sheet; historical commercial data sheet: Ni-MH (check label)

Nominal voltage

24 V

Capacity

5.5 Ah

Energy

132 Wh (24 V x 5.5 Ah)

Weight

≈ 4.38 kg according to technical data sheet (historical commercial data sheet: ≈ 1.8 kg)

Dimensions

150 x 95 x 70 mm (commercial data sheet)

Device manufacturer

Arjo

Rechargeable

Yes; recharge with the lift charger

Installation

Direct replacement in the lift compartment, without tools

Recycling

Manage in accordance with WEEE regulations

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Original Arjo Minstrel TGT223 Battery 24V 5.5Ah for Patient Lifting | Brand Replacement | Ref. 88888784”

Your email address will not be published. Required fields are marked *