We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Compatible Battery Arjo Sarita (KTA0102) 24V 2.3Ah Ni-MH for Patient Hoist | Ref. 88881143

280,00 €

Compatible battery for the Arjo Sarita patient hoist that directly replaces the original accumulator, reference KTA0102. Rechargeable Ni-MH technology, 24 V and 2.3 Ah (55.2 Wh), with dimensions of 120 x 95 x 55 mm and an approximate weight of 1.1 kg. Direct replacement in the equipment compartment, without tools, and recharging via the hoist’s own charger. Traceable solution for medical electronics maintenance and Arjo fleets in hospitals, care homes and social healthcare centres. Ref. Cahnos 88881143.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881143

Description

1. Reliable power for your Arjo Sarita lift

Keep your Arjo Sarita patient lifting system operational with this compatible 24 V 2.3 Ah battery (Ref. Cahnos 88881143). It is the direct replacement for the original accumulator with reference KTA0102 and restores the lift’s full autonomy for patient lifting, transfer and repositioning manoeuvres in hospitals, care homes, social healthcare centres and home care, without depending on the mains supply.

A practical solution for maintenance services, biomedical engineering and institutional purchasing departments that need traceable, proven-quality spare parts for their fleet of Arjo equipment. Available with fast delivery and suitable for medical electronics maintenance programmes and volume orders.

2. How this battery works in the lifting system

The Arjo Sarita patient lifting system is a patient lift that allows safe lifting and transfer of people with reduced mobility. The lifting motor is powered by an internal rechargeable battery when the equipment is not connected to the mains: as soon as the autonomy drops noticeably or the lift warns of low battery prematurely, it is time to replace the accumulator with this reference.

This battery delivers the nominal voltage of 24 V and the capacity of 2.3 Ah (55.2 Wh) required by the equipment. The Ni-MH (nickel-metal hydride) chemistry offers a very low memory effect, contains no cadmium and supports repeated charge and discharge cycles with the lift’s own integrated charger. Replacement is carried out by removing the exhausted battery from the compartment and installing the new one respecting the orientation and the connector, without the need for tools or adaptations. After installation, a full charge is recommended before first use.

3. Technical Specifications

Characteristic Specification
Application Arjo Sarita Patient Lifting System
Original reference Arjo Sarita (KTA0102)
Technology Ni-MH (Nickel-Metal Hydride), rechargeable
Nominal voltage 24 V
Capacity 2.3 Ah (2300 mAh)
Energy 55.2 Wh
Weight Approximately 1.1 kg
Dimensions 120 x 95 x 55 mm
Device manufacturer Arjo
Installation Direct replacement in the battery compartment, without tools
Presentation 1 unit
Recycling Manage in accordance with WEEE regulations

Technical note: on the market, spare parts for this same original reference KTA0102 are mostly documented in sealed lead-acid (VRLA/SLA AGM) version, 24 V / 2.3 Ah (2.9 Ah according to distribution source), with greater weight and different chemistry from the Ni-MH pack in this data sheet. Before replacing, check the chemistry, connector and dimensions of the battery fitted in your unit to ensure compatibility with the lift charger.

4. Equivalences and Cross-References

The reference for the Arjo Sarita lifting system (24 V / 2.3 Ah battery, OEM KTA0102) has been cross-checked against replacement battery manufacturers and specialist distribution catalogues. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the electrical platform (24 V, 2.3 Ah) and are classified as comparable by category, not 1:1 interchangeable, and must be validated field by field with the technical department before use in tendering.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
MSP (Medical Spare Parts) Replacement battery for Arjo lift (Sarita and Trixie) MSP-A-AH-00500 Comparable by category (not interchangeable 1:1) Replaces the original KTA0102 for Sarita and Trixie according to the manufacturer’s technical data sheet (datasheet MSP-A-AH-00500-EN); 24 V / 2.3 Ah in sealed VRLA/SLA chemistry as opposed to the Ni-MH pack in this data sheet. Check charger, connector and dimensions.
OSI Batteries Replacement biomedical battery for Arjo Sarita Lift PLB00500 Comparable by category (not interchangeable 1:1) 24 V / 2.9 Ah VRLA rechargeable; replaces OEM KTA0102 (Sarita Lift) according to authorised distribution cross-references. Chemistry, weight and dimensions differ from the Ni-MH pack in this data sheet; check compartment and connector.
Partopia Medical Battery for Arjo Sarita / Trixie Lift PM0855 (aliases 5050F / 5050-F) Comparable by category (not interchangeable 1:1) 24 V / 2.3 Ah VRLA rechargeable; replaces OEM KTA0102 according to the spare part manufacturer’s data sheet. Chemistry differs from the Ni-MH pack in this data sheet; check charger, connector and dimensions.

There is no equivalence table validated by the equipment manufacturer (Arjo) for this reference; consult the technical department before use in tendering. The 1:1 replacement must be validated field by field (voltage 24 V, chemistry of the fitted battery, capacity 2.3 Ah, dimensions and connector) against the specific equipment.

5. Selection tips and variants of interest

Confirm the reference of the fitted accumulator: this 24 V / 2.3 Ah battery is the one indicated for the Arjo Sarita patient lifting system (OEM KTA0102). Check the number printed on the original battery label before ordering.

Verify the chemistry of the batch: if your unit is fitted with a sealed lead-acid pack (VRLA), the charger is specific to that chemistry; do not install an accumulator of a different chemistry or voltage without prior technical validation, even if the connector may appear compatible.

Replace upon signs of wear: clearly reduced autonomy, premature low battery warnings or slow lifting indicate that the accumulator has reached the end of its service life.

Storage: if the lift is to remain unused for long periods, recharge it periodically (every 2-3 months) and avoid deep discharges. At the end of its service life, dispose of the battery at a WEEE collection point; never discard it as municipal waste.

Other variants of the Arjo family in our catalogue: Arjo Marisa NDA0100 battery (Ref. 88888718), 24 V / 4 Ah Ni-MH; Arjo Minstrel TGT223 battery (Ref. 88888784), 24 V / 5.5 Ah Ni-MH; Arjo Parker battery (Ref. 88888028), 24 V / 2.5 Ah; Arjo Enterprise 8000 S9097 battery (Ref. 88881188), 24 V / 1.3 Ah; and Arjo Tempo KPA0100 (Ref. 88888033) and Arjo Maxi Twin NEA0100 (Ref. 88881142) batteries, 12 V / 2.7 Ah.

To guarantee exact compatibility with your equipment, please consult our technical department: we will confirm the fit, connector and correct reference before the order is finalised, and we will advise you on institutional orders and tenders.

Additional information

Technology

Ni-MH (nickel-metal hydride), rechargeable

Nominal voltage

24 V

Capacity

2.3 Ah (2300 mAh)

Energy

55.2 Wh

Weight

Approximately 1.1 kg

Dimensions

120 x 95 x 55 mm

Application

Arjo Sarita patient lifting system (replaces original reference KTA0102)

Manufacturer reference

Arjo KTA0102

Compatibility

Arjo Sarita patient lift (OEM KTA0102); family also documented for Trixie according to spare parts manufacturers; not interchangeable with other models in the Arjo family (Marisa, Tempo, Maxi Twin, Minstrel) without technical validation

Rechargeable

Yes; recharge with the lift charger

Installation

Direct replacement in the lift compartment, without tools

Recycling

Manage in accordance with WEEE regulations