Battery Arjo Enterprise 8000 S9097 (LINAK BA20001-00) 24V 1.3Ah Lead-Acid for Patient Lift | Ref. 88881188

160,00 €

Arjo Enterprise 8000 back-up battery (S9097) with a voltage of 24 V and 1.3 Ah, built with sealed lead-acid cells (SLA/VRLA AGM) and mounted in the LINAK BA20001-00 battery box. It ensures the operation of the bed lifting system when the mains power supply fails or during patient transfer between departments. It directly replaces the original Arjo S9097 reference and fits Enterprise 5000, 8000 and 9000 beds and lifting systems. Rechargeable, maintenance-free, with protection against short circuits and overheating.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881188

Description

1. Back-up battery for Arjo Enterprise 8000 patient lifting

Ensure the continuity of care of your Arjo Enterprise 8000 beds and patient lifting systems with this rechargeable back-up battery, original reference S9097 (SKU Cahnos 88881188). Designed to intervene automatically in the event of a power supply failure or during patient transport between units, it prevents the lifting system from becoming inoperative at the worst possible moment.

It is the direct replacement for the pack fitted to the bed, and installation requires no adjustments or special tools, which makes replacement easy for the technical service or the facility’s maintenance team.

2. Technical explanation of the component

The S9097 pack is the reserve battery for the lifting system of the Arjo Enterprise acute care beds. It is housed in the LINAK battery box (item BA20001-00) and is activated when the equipment is left without mains power, keeping the lifting actuators operational for the time needed to complete the manoeuvre or transfer.

Internally it consists of two sealed lead-acid (SLA/VRLA AGM) 12 V cells connected in series, which together provide the nominal 24 V, with a capacity of 1.3 Ah. As it uses sealed AGM technology, it requires no maintenance, does not leak and can be installed in any orientation inside the bed housing with complete safety.

3. Technical Specifications

Application Arjo Enterprise 8000 patient bed and lifting system (also Enterprise 5000 and 9000 depending on authorised distributor)
Original Arjo reference S9097
Component reference (LINAK) BA20001-00 / BA2016-0200-000
Technology Sealed lead-acid, AGM/VRLA (SLA) — maintenance-free
Nominal voltage 24 V (2 cells of 12 V in series)
Capacity 1.3 Ah (1.2 Ah in compatible third-party substitutes)
Theoretical energy ≈ 31 Wh (24 V × 1.3 Ah)
Type Rechargeable back-up battery for lifting
Function Back-up in the event of a power cut and during bed transport
Connection Plug/terminal compatible with the LINAK BA20001-00 battery box
Maintenance Maintenance-free, sealed cell

Technical note: although some older commercial datasheets describe this pack as Ni-MH, the technical documentation from the component manufacturer (LINAK) and authorised distribution catalogues identify it as a sealed lead-acid SLA/VRLA AGM 24 V battery, a fact verified against multiple sources.

4. Equivalences and Cross-References

The cross-references verified in public sources (component manufacturer catalogue, authorised distributors and specialised technical store) are listed below. None of these equivalences replaces the final validation by the equipment’s technical service.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
LINAK Battery box / Battery Box for Enterprise beds (lifting system) BA20001-00 (box) and BA2016-0200-000 (complete pack) Exact reference equivalence Original component fitted in the Arjo S9097 pack: 24 V, 1.3 Ah, sealed lead-acid; same fit and connector.
MSP Medical MSP back-up battery for Enterprise beds MSP-A-AH-04400 (EAN 8719925310140) Comparable by category (not interchangeable 1:1) Declared substitute for the S9097 for Enterprise 5000 and 8000; 24 V / 1.2 Ah SLA/VRLA AGM; slightly lower capacity (1.2 vs 1.3 Ah).

There is no equivalence table validated by the manufacturer Arjo for this reference; the cross-references indicated come from the component manufacturer LINAK and authorised distributors, so it is recommended to consult the technical department before using it in a tender.

5. Selection tips and variants of interest

Before replacing the battery, check the working voltage (24 V) and the bed model (Enterprise 5000, 8000 or 9000) on the equipment nameplate; the S9097 pack is specific to the lifting system and is not interchangeable with other Arjo 12 V or higher-capacity batteries. If your fleet includes other Arjo lifting equipment, please consider the following variants available in our catalogue:

  • Arjo Marisa NDA0100 battery (Ref. 88888718): 24 V / 4 Ah Ni-MH, for Arjo Marisa lifting systems.
  • Arjo Sarita KTA0102 battery (Ref. 88881143): 24 V / 2.3 Ah Ni-MH, for Arjo Sarita lifting systems.
  • Arjo Minstrel TGT223 battery (Ref. 88888784): 24 V / 5.5 Ah Ni-MH, for Arjo Minstrel lifting systems.

To ensure exact compatibility with your equipment, please consult our technical department: we will confirm the fit, connector and correct reference before placing the order.

Additional information

Application

Arjo Enterprise 8000 patient bed and lifting system (also Enterprise 5000 and 9000 depending on distributor)

Manufacturer reference

S9097

LINAK reference

BA20001-00 / BA2016-0200-000

Technology

Sealed lead-acid (SLA/VRLA AGM)

Nominal voltage

24 V (2 cells of 12 V in series)

Capacity

1.3 Ah

Energy

≈ 31 Wh (24 V × 1.3 Ah)

Product type

Rechargeable back-up battery

Use

Back-up in the event of a power cut and during bed transport

Maintenance

Maintenance-free, sealed cell

Connection

Compatible with LINAK BA20001-00 battery box

Reviews

There are no reviews yet.

Be the first to review “Battery Arjo Enterprise 8000 S9097 (LINAK BA20001-00) 24V 1.3Ah Lead-Acid for Patient Lift | Ref. 88881188”