Description
1. The reliable power source for your Arjo Parker lift
Keep your Arjo Parker patient lift system operational with this original 24 V and 2.5 Ah battery (Ref. Cahnos 88888028). This rechargeable nickel-metal hydride (Ni-MH) battery restores the equipment’s full autonomy for patient lifting, moving and transfer manoeuvres in hospitals, care homes, social healthcare centres and home care, without relying on the mains supply.
It is the practical solution for maintenance services, biomedical engineering and institutional purchasing teams that need traceable spare parts with proven quality to keep their fleet of Arjo equipment operational. Available with fast delivery and suitable for medical electronics maintenance programmes and volume institutional orders.
2. Technical explanation: how this battery works
The Arjo Parker patient lift system (Parker bath) is a patient mobility and hygiene aid that allows people with reduced mobility to be lifted, transferred and immersed. The lift motor is powered by an internal rechargeable battery when the equipment is not connected to the mains: as soon as the autonomy drops noticeably or the lift gives a premature low-battery warning, it is time to replace the battery with this reference.
This battery delivers the nominal 24 V and the 2.5 Ah (60 Wh) capacity required by the equipment. The Ni-MH chemistry offers a very low memory effect, contains no cadmium and supports thousands of charge and discharge cycles with the lift’s own integrated charger. Replacement is carried out by removing the depleted battery from the compartment and installing the new one, respecting the orientation and connector, with no need for tools or adaptations. After installation, a full charge is recommended before first use.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Application | Arjo Parker Patient Lift System (Parker bath) |
| Reference Cahnos (SKU) | 88888028 |
| Original reference | Arjo Parker (verify the number stamped on the fitted battery) |
| Technology | Ni-MH (nickel-metal hydride), rechargeable |
| Nominal voltage | 24 V |
| Capacity | 2.5 Ah (2500 mAh) |
| Nominal energy | 60 Wh |
| Weight | Approximately 1.2 kg |
| Dimensions | 125 x 95 x 55 mm |
| Device manufacturer | Arjo |
| Rechargeable | Yes; automatic recharging with the lift charger |
| Installation | Direct replacement in the battery compartment, without tools |
| Presentation | 1 unit |
| Recycling | Manage in accordance with WEEE regulations |
Technical note: on the market, some spare parts for this same Parker application are documented in sealed lead-acid (VRLA) version, 24 V / 2.5 Ah, with greater weight and larger dimensions. Before replacing, check the chemistry, connector and dimensions of the battery fitted in your unit to ensure compatibility with the lift charger.
4. Equivalences and Cross-References
The Arjo Parker lift system reference (24 V / 2.5 Ah battery) has been cross-checked against specialist distribution catalogues and battery spare part manufacturers. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the electrical platform (24 V, 2.5 Ah) and are classified as comparable by category, not 1:1 interchangeable, and must be validated with the technical department before use in tendering.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| OSI Batteries | Biomedical replacement battery for Arjo-Century Parker Lift | B11578 | Comparable by category (not interchangeable 1:1) | VRLA (sealed lead-acid) 24 V / 2.5 Ah; same voltage and capacity but different chemistry, weight (≈2.1 kg vs 1.2 kg) and dimensions from the Ni-MH pack in this datasheet; check connector and compartment. Confirmed in the spare part manufacturer’s datasheet. |
| MSP (Medical Spare Parts) | Ni-MH pack 24 V / 2.5 Ah for Arjo lifts (Carendo, Carevo, Carino, Maxi Twin) | MSP-A-AH-00300 | Comparable by category (not interchangeable 1:1) | Ni-MH 24 V / 2.5 Ah; same electrical performance and chemistry as this datasheet, but different equipment family (Carendo/Carino/Maxi Twin vs Parker); replaces NEA0100 / NEA0100-083; check connector and dimensions. Confirmed in the spare part manufacturer’s datasheet. |
| Axcom Power Solutions | Ni-MH battery 24 V / 2.5 Ah for Arjo Maxi Twin, Maxi Twin Compact, Carino, Carendo and Carevo | MB083 (EAN 4260201689503) | Comparable by category (not interchangeable 1:1) | Ni-MH 24 V / 2.5 Ah, with warranty and declaration of conformity; equipment family different from Parker; check fit in the battery compartment. Confirmed in the spare part manufacturer’s datasheet. |
The number 88888028 under which this battery is supplied also matches the specialist distribution code used by VLAD/Exalium for the 24 V / 2.5 Ah battery of the Arjo Parker bath (documented in that catalogue in lead retrofit version), which reinforces the identification of the Parker family as supporting data. There is no equivalence table validated by the equipment manufacturer (Arjo) for this reference; consult the technical department before use in tendering. The indicated references have been cross-checked against technical datasheets from battery manufacturers and authorised distribution catalogues, but 1:1 replacement must be validated field by field (voltage 24 V, chemistry of the fitted battery, capacity 2.5 Ah, dimensions and connector) against the specific equipment.
5. Selection tips and variants of interest
- Confirm the exact equipment model: this 24 V / 2.5 Ah battery is the one indicated for the Arjo Parker patient lift system (Parker bath). Do not install it in other models in the Arjo family that use different packs, such as the Maxilift (24 V / 4 Ah, Ref. KKA1100, available at Cahnos as 88888029), even if the compartment may look similar.
- Verify the chemistry of the batch: if your unit is fitted with a sealed lead-acid (VRLA) pack, the charger is specific to that chemistry; do not install a battery of a different chemistry or voltage without prior technical validation, even if the connector may appear compatible.
- Replace upon signs of wear: clearly reduced runtime, premature low-battery warnings or slow lifting indicate that the battery has reached the end of its service life.
- Storage: if the lift is to remain unused for long periods, recharge it periodically (every 2-3 months) and avoid deep discharges. At the end of its service life, take the battery to a WEEE collection point; never dispose of it as household waste.
- Always order by reference: quote code 88888028 or the reference stamped on the fitted battery (Arjo Parker) to avoid confusion with other batteries in the Arjo family (Marisa, Maxi Twin, Opera/Tempo, Maxilift).
- Institutional orders: for consortia, tenders or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility with your batch of lifts and obtain a formal quotation with special volume-based conditions.