Description
1. Reliable power for your Accuvac Rescue suction unit
The rechargeable 12 V and 3 Ah battery for the Weinmann Accuvac Rescue mucus suction unit (Ref. 88888639) is the power replacement indicated to restore full operability to one of the reference portable suction units in emergency care. It reproduces the performance of the equipment’s original pack (manufacturer references WM10647 and WM15830, cell code N-3000CR F2X5) so that your device recovers its full autonomy without changing equipment. A rechargeable replacement, with direct installation and a very advantageous price-quality ratio compared to the official replacement, designed for maintenance services, biomedical engineering and hospital purchasing departments.
2. How this battery works in your suction unit
The Weinmann Accuvac Rescue is an autonomous secretion suction unit that works by means of a membrane pump driven by an electric motor powered by an internal battery pack. This pack of Ni-Cd (nickel-cadmium) chemistry supplies 12 V and approximately 3 Ah to generate the vacuum —adjustable between –0.05 and –0.8 bar— that extracts blood, secretions and food debris from the airway through the catheter and suction tube, collecting them in the collection jar without depending on the mains power supply.
The equipment has intelligent charging: when connected to a 12.0–13.8 V DC source (connection cable WM 10650 or mains charger WM 2610), the battery recharges automatically in about 2.5 hours. The capacity indicator shows the state of charge as a percentage and must be recalibrated each time a new pack is installed. Remember that, according to the WEINMANN IFU, self-discharge can reach 50% after 1.5 months without use at 20 °C, so it is advisable to keep the equipment connected to the charger during periods of inactivity.
3. Technical Specifications
Pack data cross-checked with the authorised distribution technical data sheet (document 88888639, 12 V 3 Ah battery for Accuvac Rescue suction unit) and with the WEINMANN Emergency IFU for the ACCUVAC Rescue.
| Characteristic | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888639 |
| Equipment manufacturer reference | WM10647 / WM15830 (original battery: N-3000CR F2X5) |
| Battery type | Ni-Cd (nickel-cadmium), rechargeable |
| Nominal voltage | 12 V |
| Nominal capacity | 3 Ah (3000 mAh); the equipment IFU lists the pack as 2.8 Ah Ni-Cd |
| Dimensions (L × W × H) | Approx. 131 × 54 × 50 mm (original Weinmann: 126 × 52 × 50 mm) |
| Approximate weight | 0.83 kg (original: 0.85 kg) |
| Connector / installation | X102 connector; direct mounting in the compartment, without tools |
| Charging voltage | 12.0 – 13.8 V DC (minimum supply of 3.2 A) |
| Weight-bearing time | Approx. 2.5 h (full charge) |
| Battery life | Approx. 45 min at maximum vacuum after 2 h of charging (according to IFU) |
| Pack service life | Approx. 400 charge/discharge cycles in about 3 years (according to IFU) |
| Compatible equipment | Weinmann Accuvac Rescue mucus suction unit; verify compartment and connector |
| Use | Suction of secretions in hospitals, emergency care, ambulances and mobile care |
| Presentation | Unit |
ACCUVAC Rescue equipment data (according to WEINMANN IFU, doc. WM 16136): maximum vacuum 0.8 bar (80 kPa), free-flow flow rate greater than 20 l/min at 12 V, motor power 50 W, maximum consumption 3.7 A, class II / BF / IPX1 classification in accordance with EN 60601-1 and EN ISO 10079-1 (high vacuum / high flow).
4. Equivalences and Cross-References
Ref. 88888639 corresponds to the standard format of the 12 V / 3 Ah Ni-Cd pack that powers the Weinmann Accuvac Rescue suction unit. The documented original equipment reference is WM10647 / WM15830 and the original cell code is N-3000CR F2X5. Warning: the designation «MFR WM11647» that appears in some distribution data sheets cannot be verified in public manufacturer sources and is probably an erroneous transcription of WM10647; it should not be used in orders or tenders without prior confirmation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Weinmann (original equipment battery) | Accuvac Rescue battery pack | WM10647 / WM15830 (cell N-3000CR F2X5) | Exact reference equivalence (original part from the equipment manufacturer) | Original Ni-Cd 12 V 3 Ah pack, approx. 126 × 52 × 50 mm and 0.85 kg; it is the part that this replacement reproduces (in authorised distribution also as 110084-O / MB1015-O). Verify batch and connector before replacement. |
| Axcom | Accuvac Rescue compatible | MB1015 (EAN 4260201680180) | Comparable by category (not interchangeable 1:1) | Ni-Cd 12 V 3 Ah, 0.85 kg, documented as compatible with WM10647 / WM15830 and with the manufacturer’s declaration of conformity. Confirmed in authorised distribution data sheet; verify dimensions and connector against the equipment. |
| Cameron Sino | Medical Replacement Battery | CS-WM1583MD | Comparable by category (not interchangeable 1:1) | Ni-MH 12 V 3000 mAh, 127.2 × 50.3 × 51 mm, 0.955 kg; replaces WM10647 / N-3000CR F2X5 for Accuvac Rescue, WM15830 and 29288. Confirmed in authorised distribution data sheet; verify chemistry (Ni-MH vs Ni-Cd) and the equipment’s charging system. |
There is no equivalence table validated by the equipment manufacturer (WEINMANN Emergency) that authorises third-party batteries; consult the technical department before use in tenders. Before a replacement, each of the following must be verified one by one: voltage (12 V), capacity (2.8–3.0 Ah), chemistry (Ni-Cd in the original; alternatives may be Ni-MH), connector (X102) and compartment dimensions (~126–131 × 52–54 × 50 mm).
5. Selection tips and variants of interest
Identify the exact model of your equipment: this battery is the one indicated for the Weinmann Accuvac Rescue (equipment refs. WM 10600, WM 10620, WM 10811 and WM 10812; original battery WM10647 / WM15830). Do not replace it with batteries of a different chemistry or voltage: for example, the Accuvac Basic uses a sealed lead-acid cell of 12 V 3.4 Ah (Ref. 88889560) and the Accuvac Pro a specific unit (Ref. 88889273); an incorrect replacement may damage the device’s charging system.
Maintenance: after installing a new pack, recalibrate the capacity indicator following the IFU. Do not fully discharge the battery (recharge it when the LED indicates 30 % and, at the latest, when the red LED at 10 % lights up), do not store it discharged and perform a periodic recharge every 6 weeks during periods of inactivity. At the end of its service life, dispose of it at a WEEE collection point.
Variants of the same family on Cahnos: the battery for the Accuvac Basic (Ref. 88889560), that for the Accuvac Pro (Ref. 88889273) and packs for other portable suction units such as the Asskea DC30 (Ref. 88888039) or the ATMOS Atmoport 2-S (Ref. 88888043). They are not interchangeable with this reference without technical verification.
For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility with your equipment fleet, delivery times and a formal quotation.





Reviews
There are no reviews yet.