Description
1. Commercial Introduction
Keeping your infusion pump Fresenius Optima MS running even when no mains power is available is a daily requirement in hospitals, clinics and patient transport services. With the rechargeable Ni-MH battery, 6 V and 3 Ah (Ref. Cahnos 88888176) you will have a reliable, maintenance-free, ready-to-install replacement that replaces the original equipment references 120238 / RC3000SC05AA.
It is the ideal solution for intensive care, emergency, oncology and hospitalisation units and medical electronics maintenance contracts that need to guarantee continuous patient infusion during transfers, supply interruptions or equipment mobilisation.
2. Technical explanation of the equipment and the battery
The Optima MS (Fresenius Vial / Fresenius Kabi) is a volumetric infusion pump that administers fluids, drugs and solutions at a controlled flow rate by means of a peristaltic mechanism, with safety functions such as occlusion and air detection. The pump has an internal rechargeable battery that acts as a backup power source: while the device remains connected to the mains, the battery recharges automatically; when the device is disconnected or in the event of a power cut, the battery takes over the power supply and the infusion is not interrupted.
This battery uses Ni-MH (nickel-metal hydride) chemistry, cadmium-free and with a very low memory effect, with 6 V nominal voltage and 3 Ah capacity (3000 mAh / 18 Wh). It provides up to the battery life declared by the equipment manufacturer depending on the programmed flow rate and recharges automatically with the pump connected to the mains. When battery life is noticeably reduced or the pump warns of low battery prematurely, it is time to replace the accumulator with this reference.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88888176 |
| Battery type | Ni-MH (nickel-metal hydride), rechargeable, maintenance-free |
| Nominal voltage | 6 V |
| Nominal capacity | 3 Ah (3000 mAh / 18 Wh) |
| Original manufacturer references replaced | 120238 / RC3000SC05AA |
| Approximate dimensions of the pack | ≈ 68 x 45 x 43 mm (according to cell manufacturer: 67.9 x 44.6 x 43.0 mm) |
| Approximate weight | ≈ 300–355 g |
| Chemistry | Ni-MH, cadmium-free, very low memory effect |
| Compatibility | Fresenius Optima MS volumetric infusion pump (also documented for Optima PT, Optima ST, Optima VS and MCM440 PT/OT, MCM550 ST) |
| Recharge | Automatic with the pump connected to the mains |
| Maintenance | Maintenance-free; check condition during periodic medical electronics inspections |
| Intended use | Hospital, ICU, emergency, oncology and intra-hospital transfers |
| Presentation | 1 unit |
Actual battery life depends on the programmed flow rate and the condition of the device; consult the Optima MS pump user manual for the battery operating times in each configuration.
4. Equivalences and Cross-References
Ref. Cahnos 88888176 corresponds to the 6 V / 3 Ah Ni-MH battery fitted as standard on the Fresenius Optima MS pump, whose original factory references are 120238 and RC3000SC05AA (consistently verified across multiple technical sources from European and American distributors). Fresenius Kabi does not publish an official cross-reference table for this accumulator; the alternatives listed below share chemistry, voltage, capacity and compatibility and are considered comparable by category, not 1:1 interchangeable, and the connector and orientation must be verified before installation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Ni-MH battery for Fresenius Optima MS / Optima PT-ST-VS / MCM440-550 | CS-FRV440MD | Comparable by category (not interchangeable 1:1) | Ni-MH 6 V / 3000 mAh (18 Wh), 67.9 x 44.6 x 43.0 mm, ~355 g; replaces 120238 and RC3000SC05AA; documented compatibility with Optima MS, PT, ST, VS and MCM440/550. Data cross-checked in the battery manufacturer’s technical data sheet. |
| Axcom | Ni-MH battery for Fresenius MCM 440 / MC 550 / Optima | MB440 | Comparable by category (not interchangeable 1:1) | Ni-MH 6 V / 3 Ah, compatible according to the data sheet with Optima MS, PT, ST, VS and MCM440/MCM550; verify pack dimensions and connector according to batch. Authorised distributor technical data sheet consulted. |
There is no equivalence table validated by the manufacturer (Fresenius Kabi) that cross-references this reference with third parties; the listed alternatives are comparable by category and must be checked against the technical data sheet and the equipment manual before use. Consult the technical department before using this reference in tenders.
Verification note: the code 120238 appears in some internal tables associated with the Applix family; the specialised sources consulted assign it to the 6 V / 3 Ah battery of the Optima and MCM440 pumps, so it must not be used for the 4.8 V / 1.2 Ah reference of the Applix Smart.
5. Selection tips and variants of interest
- Confirm the exact pump model: this battery corresponds to the Optima MS (6 V / 3 Ah, Ni-MH). Do not confuse it with the 12 V / 1.8 Ah battery for Fresenius Optima (Ref. 88888174) or with the 6 V / 1.8 Ah battery for Injectomat Agilia (Ref. 88888184), although the connector may look similar.
- Verify the fitted battery reference: check the codes 120238 or RC3000SC05AA on the accumulator label before replacing. Always respect the voltage (6 V) and the Ni-MH chemistry; do not use lead batteries or batteries of another voltage.
- Replace when signs of wear appear: clearly reduced battery life or low battery warnings a few hours after charging indicate that the accumulator has reached the end of its service life.
- After replacement: leave the pump connected to the mains to complete the charge and verify that the battery indicator reflects the new status before returning the device to service.
- Orders by reference: always quote the code 88888176 or that of the original reference (120238 / RC3000SC05AA) to avoid confusion with other batteries in the Fresenius family.
- Other variants of the same family in the catalogue: 88888174 (12 V / 1.8 Ah for Optima), 88888184 (6 V / 1.8 Ah for Injectomat Agilia), 88888173 (6 V / 1.3 Ah for Orchestra MVP-DPS), 88888186 (6 V / 1.2 Ah for Pilot A-C Prog 1) and 88888178 (4.8 V / 1.2 Ah for Applix Smart).
- If in any doubt, contact our technical department stating the model, serial number and reference of the fitted battery; we will confirm compatibility before you place the order.