Description
1. Commercial Introduction
At Cahnos we offer you the Ni-MH rechargeable battery of 6 V and 1.8 Ah for the Fresenius Kabi Injectomat Agilia syringe pump (Ref. 88888184), a high-performance compatible spare part designed to keep infusion and perfusion running when the equipment is not connected to the mains. The reference covers the original manufacturer numbers Z178130, RC1800AA05AA and 110238, commonly cited in the spare parts market for this family of equipment, and is also documented for Agilia Vial Injectomat S, MCM Injectomat S and Infusionspumpe MCM440. Available with delivery in 24/72 h for intensive care, anaesthesia, oncology, emergency, hospitalisation units and medical electronics maintenance programmes.
2. Technical explanation of the equipment
The Fresenius Kabi Injectomat Agilia syringe pump administers medications parenterally continuously or intermittently (anaesthetics, sedatives, analgesics, catecholamines and others), with syringes of different sizes and programmable flow rates. Its internal battery acts as a backup source: when the pump is disconnected from the mains, moved to the patient or there is a power cut, the battery automatically takes over the power supply to the syringe motor and control system without interrupting the infusion.
This battery uses nickel-metal hydride (Ni-MH) chemistry, rechargeable, with no significant memory effect and stable current delivery, suitable for the motorised system of the pump. It recharges automatically while the equipment remains connected to the mains. When the pump’s autonomy is noticeably reduced or the equipment warns of low battery, it is time to replace the cell to ensure safety and continuity of the infusion.
3. Technical Specifications
Ref. 88888184 corresponds to a Ni-MH battery of 6 V and 1.8 Ah documented in our catalogue and in specialised technical distribution for the equipment of the Agilia family from Fresenius Kabi. The original cell of the equipment corresponds to the standard AA high-capacity format (H-AA1800B), with a specific connector for the contact block of the pump compartment.
| Parameter | Specification |
| Reference Cahnos | 88888184 (internal SKU 0159027) |
| Battery type | Nickel-metal hydride (Ni-MH), rechargeable |
| Nominal voltage | 6 V DC |
| Nominal capacity | 1.8 Ah (1800 mAh) |
| Original references covered | Z178130, RC1800AA05AA, 110238, H-AA1800B |
| Compatible equipment | Fresenius Kabi Injectomat Agilia (syringe pump); Agilia Vial Injectomat S; MCM Injectomat S; Infusionspumpe MCM440 |
| Approximate cell dimensions | 72.2 x 51.6 x 15.4 mm (according to documented compatible cell; verify with the mounted part) |
| Approximate weight | 0.25 kg |
| Chemistry / memory effect | Ni-MH, cadmium-free, very low memory effect |
| Rechargeable | Yes; automatic recharging when the equipment is connected to the mains |
| Presentation | Unit |
| Intended use | ICU, emergency, anaesthesia, oncology, hospitalisation and intra-hospital transport |
4. Equivalences and Cross-References
Ref. 88888184 is documented in our catalogue as the compatible 6 V and 1.8 Ah battery for the Fresenius Injectomat Agilia syringe pump, covering OEM numbers Z178130, RC1800AA05AA and 110238, consistently confirmed in authorised technical distribution catalogues and specialised industry databases (reference Z178130 also appears as a manufacturer reference in our internal documentation). Fresenius Kabi does not publish an official cross-reference table for this battery; the alternatives indicated share chemistry and voltage with our spare part and require field-by-field verification before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Fresenius Kabi (equipment manufacturer) | Original Injectomat Agilia battery | Z178130 | Comparable by category (not interchangeable 1:1) | Original equipment reference covered by this battery: Ni-MH 6 V, 1.8 Ah. Same electrical performance; our spare part is not manufactured by Fresenius Kabi. Confirmed in internal documentation and authorised technical distribution. |
| Fresenius Kabi (equipment manufacturer) | Original battery for Agilia family (Vial/MCM) | RC1800AA05AA, 110238, H-AA1800B | Comparable by category (not interchangeable 1:1) | Alternative numbers for the same accumulator consistently cited by specialised technical distributors for Injectomat Agilia, Agilia Vial Injectomat S and MCM Injectomat S. Verify the number engraved on the mounted battery. |
| Camero (Cameron Sino) | CS Series for Fresenius Agilia | CS-FRV238MD | Comparable by category (not interchangeable 1:1) | Replacement battery Ni-MH 6 V / 2100 mAh (12.6 Wh), 72.2 x 51.6 x 15.4 mm, ~0.25 kg; replaces the same OEM references (Z178130, RC1800AA05AA, 110238, H-AA1800B). Capacity slightly higher than 1.8 Ah; verify compartment and connector (positive terminal orientation on the left). Manufacturer/distribution data sheet consulted. |
There is no equivalence table validated by the manufacturer (Fresenius Kabi) that cross-references this reference with third parties; the references indicated have been verified against internal documentation and authorised technical distribution catalogues, but 1:1 substitution must be validated field by field (Ni-MH chemistry, 6 V voltage, capacity, dimensions, connector type and terminal orientation). Consult the technical department before using in a tender.
5. Selection tips and variants of interest
- Identify the exact equipment: this battery is the one specified for the Injectomat Agilia syringe pump and associated equipment (Agilia Vial Injectomat S, MCM Injectomat S, Infusionspumpe MCM440). Other pumps from the brand (Orchestra MVP-DPS, Pilot A-C, Optima, Programa 2) use cells of different capacity or chemistry; do not assume interchangeability without checking the compartment.
- Check the label on the fitted battery: confirm the voltage (6 V), chemistry (Ni-MH) and part number (Z178130, RC1800AA05AA, 110238 or another) before replacing. Do not use lead batteries or batteries of a different voltage without validation from the technical service department.
- After replacement: perform a recommended full charge (at least 12-16 h after a full discharge) and an autonomy test before returning the pump to clinical service.
- Storage: store the battery in a dry place, at room temperature, and with periodic charges if the equipment remains unused, to extend its service life.
- Variants of the same family in Cahnos: battery 6 V / 1.3 Ah for Orchestra MVP-DPS (Ref. 88888173), 6 V / 1.2 Ah for Pilot A-C Prog 1 (Ref. 88888186), 6 V / 3.5 Ah for Programa 2 (Ref. 88888187), 6 V / 3 Ah for Optima MS (Ref. 88888176) and 12 V / 1.8 Ah for Optima (Ref. 88888174). Do not interchange these references between models.
- Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formal quotation.