We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

6V 1.2Ah sealed lead-acid battery for Fresenius Pilot A-C Prog 1 syringe pump | Cell A506/1.2S · Format NP1.2-6 | Ref. 88888186

56,00 €

Rechargeable sealed lead-acid battery, 6V and 1.2Ah (NP1.2-6 format) for the Fresenius Pilot A-C Prog 1 syringe pump, corresponding to the A506/1.2S cell referenced in the equipment. Maintenance-free spare part that guarantees the continuity of infusion and perfusion during transfers or power cuts, with automatic recharging when the pump is connected to the mains and direct replacement in the original compartment. Ref. 88888186. Ideal for ICU, emergency, anaesthesia, oncology and hospitalisation.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88888186

Description

1. Commercial Introduction

Keeping your Fresenius Pilot A-C Prog 1 syringe pump running even when mains power is unavailable is a daily requirement in hospitals, clinics and ambulance services. With the rechargeable 6V 1.2Ah battery (Ref. Cahnos 88888186) you will have a reliable, maintenance-free, ready-to-install replacement that matches the sealed lead cell fitted as standard on this device and referred to in the market as A506/1.2S.

It is the ideal solution for intensive care, emergency, anaesthesia, oncology, hospitalisation units and medical electronics maintenance contracts that need to ensure continuous patient infusion during transfers, power interruptions or equipment mobilisation.

2. Technical explanation of the equipment and the battery

The Fresenius Pilot A-C Prog 1 is a syringe pump for infusion and perfusion from the Fresenius Kabi family (formerly Fresenius Vial) that administers drugs parenterally continuously or intermittently (anaesthetics, sedatives, analgesics, cytostatics and others), with syringes of different sizes, programmable flow rates, occlusion detection and end-of-infusion and low battery alarms.

The pump incorporates an internal rechargeable battery that acts as a backup power source: while the device remains connected to the mains, the battery charges automatically; when the pump is disconnected, moved or in the event of a power cut, the battery takes over powering the syringe motor and control system without interrupting the infusion. This battery uses sealed lead-acid (SLA/VRLA) chemistry in a standard NP1.2-6 cell format, completely sealed, maintenance-free and delivering stable current suitable for the device’s motorised system. When the battery life is noticeably reduced or the pump gives a premature low battery warning, it is time to replace the battery with this reference.

3. Technical Specifications

Ref. 88888186 corresponds to the 6V 1.2Ah sealed lead battery documented in our catalogue for the Fresenius Pilot A-C Prog 1 syringe pump. The dimensions correspond to the standard NP1.2-6 cell and the numbering A506/1.2S (Exide Sonnenschein dryfit) cited in the device reference; data verified against the official technical data sheets of the cell manufacturers.

Parameter Specification
Reference Cahnos (SKU) 88888186
Battery type Sealed lead-acid (SLA/VRLA), AGM, rechargeable, maintenance-free
Nominal voltage 6 V
Nominal capacity 1.2 Ah (1200 mAh)
Cell format NP1.2-6 (standard cell 6 V / 1.2 Ah)
Cell numbering cited on the equipment A506/1.2S (Exide Sonnenschein dryfit) / A506/1.25
Approximate dimensions 97.3 x 25.5 x 54.9 mm
Approximate weight 0.29 kg
Terminals Faston 4.8 mm (F1)
Charge voltage (float) 6.75 – 6.90 V at 25 ºC (standard cell datasheet)
Charge voltage (cyclic) 7.20 – 7.50 V at 25 ºC (standard cell datasheet)
Compatible equipment Syringe infusion/perfusion pump Fresenius Pilot A-C Prog 1 (A506/1.25)
Recharge Automatic with the pump connected to the mains
Maintenance Maintenance-free; periodic inspection in medical electronics programmes
Intended use Hospital, ICU, emergency, anaesthesia, oncology and intra-hospital transport
Presentation 1 unit

Behaviour during operation:

Condition Behaviour
Device connected to the mains The battery recharges automatically; the screen indicator shows the charge status
Device disconnected or power cut The battery powers the syringe motor without interrupting the perfusion
Battery life Depends on the programmed flow rate and the battery condition; consult the pump manual (low battery warning on screen)
Replacement Direct in the original compartment, without modifying the device; recommended with the pump switched off

4. Equivalences and Cross-References

Ref. Cahnos 88888186 is documented as the 6V 1.2Ah sealed lead battery for the Fresenius Pilot A-C Prog 1 pump. The cell fitted as standard corresponds to the standard NP1.2-6 format and the Exide Sonnenschein A506/1.2S numbering, cited in the device’s commercial reference as A506/1.25. Fresenius Kabi does not publish an official cross-reference table for this battery; the cells listed below share chemistry, voltage, capacity and dimensions with our replacement and are considered comparable by category, not 1:1 interchangeable, and the connector and orientation must be verified before installation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Yuasa NP series (general purpose / standby) NP1.2-6 Comparable by category (not interchangeable 1:1) 6 V, 1.2 Ah, sealed lead-acid AGM (VRLA), 97 x 25 x 54.5 mm, Faston 4.8 mm terminal (F1), maintenance-free. Same electrical performance and very close dimensions; verify orientation and wiring. Official Yuasa technical data sheet consulted.
Power Sonic PS series (general use) PS-612 Comparable by category (not interchangeable 1:1) 6 V, 1.2 Ah, sealed lead-acid AGM (VRLA), 97.0 x 23.9 x 50.8 mm (lower overall height), F1 terminal. Official Power Sonic datasheet consulted.
Exide Sonnenschein A500 dryfit series (gel) A506/1.2S Comparable by category (not interchangeable 1:1) 6 V, 1.2 Ah (C20), gel (GEL) dryfit technology, 97.3 x 25.5 x 55.6 mm, 4.8 mm connector, approx. 0.33 kg. Cell numbering cited in the device reference (A506/1.25). Official Exide technical data sheet consulted.

There is no equivalence table validated by the manufacturer (Fresenius Kabi) that cross-references this part with third parties; the cells listed are comparable by category and must be verified against the technical data sheet and the device manual before use. It is recommended to confirm the numbering stamped on the fitted cell before replacing. Consult with the technical department before using this reference in tenders.

5. Selection tips and variants of interest

  • Confirm the exact pump model: this battery is the one indicated for the Fresenius Pilot A-C Prog 1 syringe pump (6V / 1.2Ah, sealed lead). Other pumps of the brand use cells of different capacity or chemistry; do not assume interchangeability without checking the compartment.
  • Check the label of the fitted cell: confirm voltage (6 V), chemistry (sealed lead) and numbering (NP1.2-6, A506/1.2S or other) before replacing. Do not use batteries of other chemistry or voltage without validation from the technical service.
  • Replace when signs of wear appear: clearly reduced battery life or low battery warnings a few hours after charging indicate that the battery has reached the end of its service life.
  • After replacement: leave the pump connected to the mains to complete the charge and verify that the battery indicator reflects the new status before returning the device to service.
  • Storage: keep the battery in a dry place, at room temperature and with periodic charges if the device remains unused, to extend its service life.
  • Other variants of the same family in catalogue: 88888173 (6V / 1.3Ah for Orchestra MVP-DPS), 88888184 (6V / 1.8Ah for Injectomat Agilia), 88888187 (6V / 3.5Ah for Programme 2), 88888176 (6V / 3Ah for Optima MS) and 88888174 (12V / 1.8Ah for Optima). Do not interchange these references between models.
  • Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department indicating the model, serial number and reference of the fitted battery; we will confirm compatibility before formalising the order.

Additional information

Battery type

Sealed lead-acid (SLA/VRLA), AGM, rechargeable, maintenance-free

Nominal voltage

6 V

Nominal capacity

1.2 Ah (1200 mAh)

Cell format

NP1.2-6 (standard cell 6 V / 1.2 Ah)

Equipment cell reference

A506/1.2S (Exide Sonnenschein dryfit) / A506/1.25

Dimensions

97.3 x 25.5 x 54.9 mm

Weight

0.29 kg

Terminals

Faston 4.8 mm (F1)

Compatibility

Syringe infusion/perfusion pump Fresenius Pilot A-C Prog 1

Recharge

Automatic with the pump connected to the mains

Float charge voltage

6.75 – 6.90 V at 25 ºC (standard cell datasheet)

Cyclic charge voltage

7.20 – 7.50 V at 25 ºC (standard cell datasheet)

Maintenance

Maintenance-free; periodic inspection in medical electronics programmes

Intended use

Hospital, ICU, emergency, anaesthesia, oncology and intra-hospital transport

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “6V 1.2Ah sealed lead-acid battery for Fresenius Pilot A-C Prog 1 syringe pump | Cell A506/1.2S · Format NP1.2-6 | Ref. 88888186”

Your email address will not be published. Required fields are marked *