Description
1. Commercial Introduction
At Cahnos we offer you the rechargeable 6 V, 1.3 Ah battery for the Codan Argus 600S syringe pump (Ref. 88888262), a compatible sealed lead-acid, maintenance-free replacement, designed to keep infusion and perfusion running when the device is not connected to the mains. Available with delivery in 24/72 h for intensive care, anaesthesia, oncology, emergency departments, hospitalisation units and medical electronics maintenance programmes.
2. Technical Explanation
The Codan Argus 600S syringe pump, manufactured by ARGUS Medical AG (a member of the Codan group), administers drugs via parenteral and enteral routes continuously or intermittently (anaesthetics, sedatives, analgesics, catecholamines and others). Its internal battery allows the device to continue infusing safely during transfers, in rooms without mains power or in the event of a power cut.
This sealed lead-acid battery recharges automatically while the pump remains connected to the mains. According to the manufacturer’s service manual, with the standard 6 V/1.2 Ah battery the typical battery life is around 2 hours at a rate of 5 ml/h; when the discharge time falls below this value, the manual recommends replacing the battery (original part 12,032). After replacement, it is advisable to recalibrate the battery capacity indication from the configuration menu (index 368 / address 200) and perform the standard safety check (SSC), which the manufacturer recommends every 24 months or 10,000 hours of operation. Our reference 88888262 offers 1.3 Ah nominal capacity, slightly higher than the original, in the same cell format (NP1.2-6) and without the need to modify the device.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888262 |
| Battery type | Sealed lead-acid, rechargeable, maintenance-free |
| Nominal voltage | 6 V |
| Nominal capacity | 1.3 Ah |
| Compatible cell format | NP1.2-6 (approx. 97 x 55 x 24 mm; weight approx. 0.29 kg) |
| Compatibility | Codan Argus 600S syringe pump (ARGUS Medical AG, Codan group) |
| Original device references | 12,032 (standard battery 6 V/1.2 Ah) and 12,026 (high energy 6 V/4 Ah) |
| Typical battery life | Approx. 2 h at 5 ml/h (according to ARGUS 600 S service manual) |
| Recharge | Automatic with pump connected to mains; after complete discharge, full charge recommended at least 16 h |
| Installation | Direct replacement in the original compartment; recommended to be carried out with the device switched off and subsequent verification by authorised technical personnel |
| Maintenance | Maintenance-free; capacity recalibration (index 368 / address 200) and standard safety check (SSC) every 24 months or 10,000 h of operation |
4. Equivalences and Cross-References
The commercial reference 88888262 corresponds to a compatible 6 V/1.3 Ah battery for the Codan Argus 600S syringe pump. The device manufacturer identifies the original standard battery as part 12,032 (6 V/1.2 Ah) according to its service manual; replacement with a slightly higher capacity cell (1.3 Ah) is compatible and common in the spare parts market. It has also been verified that the standard cell format used is NP1.2-6, a reference used by specialised technical distributors to list batteries for this same pump.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| ARGUS Medical AG (Codan group) | ARGUS 600 S standard battery (original device battery) | 12,032 | Comparable by category (not interchangeable 1:1) | Original device battery, 6 V/1.2 Ah; our ref. 88888262 offers 6 V/1.3 Ah nominal, compatible with the same compartment and connector |
| ARGUS Medical AG (Codan group) | ARGUS 600 S high energy battery | 12,026 | Comparable by category (not interchangeable 1:1) | 6 V/4 Ah, much higher battery life (approx. 8 h); requires 4 Ah battery cover (part 11,267) and recalibration of the capacity menu |
| Technical distributors (Vlad / Ammirata) | Compatible Argus 600S battery, NP1.2-6 format | 88890369 / PS612ST | Comparable by category (not interchangeable 1:1) | Same sealed lead-acid chemistry and NP1.2-6 format; before replacing, check connector, terminal orientation and fixing in the compartment |
| Yuasa | Sealed lead-acid battery NP series | NP1.2-6 | Comparable by category (not interchangeable 1:1) | Standard cell 6 V/1.2 Ah, 97 x 25 x 54.5 mm; NP1.2-6 format documented for this pump; requires assembly with the original device connector |
| Panasonic Energy | Sealed lead-acid battery LC series | LC-R061R3P | Comparable by category (not interchangeable 1:1) | 6 V/1.3 Ah, 97 x 24 x 55 mm, weight approx. 0.30 kg; same dimensions and chemistry; check terminals and fixing before mounting |
There is no equivalence table validated by the manufacturer that cross-references this commercial reference with third parties; the references indicated have been verified against the service manual, manufacturer technical data sheets and authorised distribution catalogues, but 1:1 substitution must be validated field by field (chemistry, voltage, capacity, dimensions, connector type and terminal orientation). Consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Check the exact model of your pump: this battery is intended for the Argus 600S syringe pump. Other pumps in the Codan group (e.g. Argus 707/708, volumetric pumps) use different batteries, such as reference 601259, 12 V, which are not interchangeable with this one.
- Battery life and capacity: if your service requires long periods without mains power (transfers, ambulances), consider the high-energy 6 V/4 Ah variant (original part 12,026), provided the device accepts the corresponding battery cover.
- After replacement: adjust the battery capacity indicator in the configuration menu (index 368 / address 200) and perform the standard safety check (SSC) according to the service manual: every 24 months or after 10,000 operating hours.
- Storage: keep the battery in a dry place, at room temperature and with periodic charges if the device remains unused, to extend its service life.
- Intended use: the pump accepts syringes from 10 to 60 ml with Luer-Lock type connection; always use consumables recommended by the device manufacturer.
- Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.





Reviews