Rechargeable Ni-MH battery 9.6V 2.4Ah for Carefusion / BD Alaris Asena Gateway syringe pump | Replaces 1000SP00605 and 1000SP01795 | Ref. 88881138

400,00 €

Rechargeable Ni-MH battery, 9.6 V and 2.4 Ah (≈23 Wh) for syringe pumps and Carefusion / BD Alaris Asena Gateway stations, Ref. Cahnos 88881138. Replaces the equipment’s original references 1000SP00605, 1000SP01795, 110475-O, 110475-U and 80203UNS02, restoring the pump’s full autonomy with automatic recharging when connected to the mains. Cadmium-free chemistry, very low memory effect and direct fit in the original compartment, without tools or adaptations. Ideal for hospitals, clinics, ICUs, oncology and intra-hospital transport; see B2B terms for fleet orders and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881138

Description

1. The reliable power source for your Asena Gateway pump

At Cahnos we offer you the rechargeable battery of 9.6 V and 2.4 Ah for the syringe pumps and stations of the Carefusion / BD Alaris Asena Gateway family (Ref. 88881138), infusion and perfusion equipment widely used in hospital wards, intensive care units, anaesthesia, oncology and emergency departments. It is a nickel-metal hydride (Ni-MH) accumulator, cadmium-free and with a very low memory effect, which restores the equipment to full battery operation, both for continuous treatments and for patient transfers without mains connection.

It is the practical solution for medical electronics maintenance services, biomedical engineering and hospital purchasing departments that need a proven and traceable spare part, consistently linked to the original equipment references 1000SP00605, 1000SP01795, 110475-O, 110475-U and 80203UNS02, at a very contained cost compared to the manufacturer’s official replacement.

2. How this battery works

The Asena Gateway syringe pump administers drugs and fluids at a controlled flow rate over prolonged periods using syringes of different sizes. To ensure continuity of infusion when the equipment is not connected to the mains, it incorporates an internal rechargeable battery that recharges automatically while the pump remains plugged in.

This Ni-MH accumulator of 9.6 V / 2.4 Ah (≈23 Wh) delivers the nominal voltage and capacity required by the equipment and is managed by the pump’s own charging circuit. The Ni-MH chemistry offers a stable discharge curve, absence of cadmium and a long service life with hundreds of charge and discharge cycles. When the autonomy is noticeably reduced or the pump warns of low battery prematurely, it is time to replace the pack with this reference. Installation is simple: the battery is inserted into the internal compartment of the equipment without the need for adjustments or special tools, and recharging is carried out in the pump itself when it is connected to the mains.

3. Technical Specifications

Ref. 88881138 corresponds to the rechargeable Ni-MH pack of 9.6 V / 2.4 Ah documented for the Asena Gateway family, with the nominal specifications of the original equipment battery (1000SP00605 / 1000SP01795) verified in technical sources from authorised distribution.

Characteristic Specification
Reference Cahnos (SKU) 88881138
Original equipment references it replaces 1000SP00605, 1000SP01795, 110475-O, 110475-U and 80203UNS02 (Carefusion / BD / Alaris Medicalsystems)
Accumulator type Ni-MH (nickel-metal hydride), rechargeable, cadmium-free
Nominal voltage 9.6 V
Nominal capacity 2.4 Ah (2,400 mAh / ≈23 Wh)
Pack configuration Pack of 1.2 V cells in series, according to the original version of the equipment
Approximate dimensions ≈75.3 x 53.3 x 31.6 mm (according to market spare parts; verify against the original part)
Approximate weight ≈0.36–0.39 kg
Compatibility Carefusion / BD Alaris Asena Gateway syringe pumps and stations (Gateway Workstation); documented use in Asena DS (verify batch and connector)
Recharge Automatic, integrated in the pump when connected to the mains
Installation Direct replacement in the battery compartment, without tools
Use Continuous infusion and perfusion in hospitals, clinics, ICU, oncology, anaesthesia, emergency departments and intra-hospital transport
Recycling Manage in accordance with WEEE regulations
Presentation 1 unit

Note: the voltage and capacity indicated correspond to the nominal specification of the original equipment battery (1000SP00605 / 1000SP01795, 9.6 V / 2,400 mAh) and of the documented market replacements. Always verify the compartment, the connector and the chemistry of the installed part before replacement.

4. Equivalences and Cross-References

Ref. Cahnos 88881138 corresponds to the 9.6 V / 2.4 Ah Ni-MH battery fitted in the Asena Gateway family, whose original factory part numbers are 1000SP00605, 1000SP01795, 110475-O, 110475-U and 80203UNS02, consistently verified in multiple technical sources from authorised distribution. No registration exists in GUDID/EUDAMED for this generic replacement; treat these codes as catalogue data and original equipment reference. The equipment manufacturer does not publish an official cross-reference table with third-party batteries; the alternatives listed below share chemistry (Ni-MH) and voltage (9.6 V) with this reference and are classified as comparable by category (not 1:1 interchangeable), and capacity, dimensions and connector must be verified against the specific equipment.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cameron Sino Ni-MH battery for Alaris Medical System Gateway Workstation (Typ 1000SP00605) / CareFusion Syringe Pump Asena Gateway CS-CFA475MD (also MED-CS-CFA475MD / CS-CFA475MD.2) Comparable by category (not interchangeable 1:1) Ni-MH 9.6 V / 2,500 mAh (≈25.2 Wh), ≈75.3 x 53.3 x 31.6 mm and ≈388 g; replaces 1000SP00605, 110475-O, 110475-U, 88881138, 1000SP01795 and 80203UNS02. Slightly higher capacity (2.5 vs 2.4 Ah) and pack dimensions according to assembly; verify connector and compartment according to batch. Confirmed in the battery manufacturer’s technical data sheet and authorised distribution.
Euro Energy (authorised distributor) Original battery for Carefusion / BD Asena Gateway Syringe Pump 02367 Comparable by category (not interchangeable 1:1) Corresponds to the original BD battery 1000SP01795: Ni-MH 9.6 V / 2,400 mAh (2.4 Ah), same chemistry, voltage and capacity as this reference; supplier’s own commercial number for the genuine part. Verified in the authorised distributor’s catalogue.

Other biomedical replacement assemblers operate in the market offering packs compatible with the Asena Gateway 9.6 V Ni-MH (e.g., AKKP-110475-O type replacements from AKKUmed associated with P/N 110475-O); their codes are not cited in the table as they do not always provide a stable reference with complete attributes in public sources, so they are considered pending confirmation with the manufacturer. There is no equivalence table validated by the equipment manufacturer (Carefusion / BD) that cross-references this reference with third-party batteries on a 1:1 basis; consult the technical department before use in tenders. Before a replacement, the following must be verified one by one: voltage (9.6 V), chemistry (Ni-MH), capacity (2.4 Ah or close), pack dimensions and connector against the specific equipment (Asena Gateway / Gateway Workstation / Asena DS).

5. Selection tips and variants of interest

  • Confirm the exact model of the pump: this 9.6 V / 2.4 Ah battery is the one indicated for the Asena Gateway station and syringe pumps (Gateway Workstation). Do not use it in the Asena GW volumetric pump (Graseby), which uses a different 7.2 V / 1.7 Ah battery (Ref. 88888022), nor in the Asena GS-GH syringe pumps (7.2 V / 2.7 Ah, Ref. 88888021) or Asena GP / GP+ (9.6 V / 2.1 Ah, Ref. 88890298), even though the connector may look similar.
  • Respect the voltage and chemistry: do not use batteries of a different voltage (7.2 V, 12 V) or a different chemistry (Li-ion, Ni-Cd) in this pump without prior technical validation, even if they fit physically; the equipment’s charging circuit is calibrated for 9.6 V Ni-MH.
  • Check the label on the fitted battery: confirm voltage (9.6 V), chemistry (Ni-MH) and part number (1000SP00605 / 1000SP01795 / 110475-O / 110475-U or another) before replacing.
  • Replace upon signs of wear: clearly reduced runtime or low-battery warnings within a few hours of charging indicate that the battery has reached the end of its service life. Perform a full charge after installation and avoid repeated deep discharges.
  • Always order by reference: quote code 88881138 or the equipment’s original reference (1000SP00605 / 1000SP01795 / 110475-O / 110475-U) to avoid confusion with other batteries in the Asena and Alaris family.
  • For mixed fleets: consult our catalogue of batteries for infusion and perfusion pumps; we stock spare parts for the Carefusion Alaris Asena (Gateway, GP, GS-GH, GW), Signature, Graseby, B. Braun, Terumo and Fresenius families, among others. For tenders or procurement procedures, contact our technical-commercial department to confirm compatibility with your equipment batch and formalised quotation.

Additional information

Accumulator type

Ni-MH (nickel-metal hydride), rechargeable, cadmium-free

Nominal voltage

9.6 V

Nominal capacity

2.4 Ah (2,400 mAh / ≈23 Wh)

Compatibility

Syringe pumps and stations Carefusion / BD Alaris Asena Gateway (Gateway Workstation); Asena DS according to batch

Dimensions

≈75.3 x 53.3 x 31.6 mm (according to market spare parts; verify against the original part)

Approximate weight

≈0.36–0.39 kg

Chemistry

Nickel-metal hydride (Ni-MH), cadmium-free

Recharge

Automatic, integrated in the pump when connected to the mains

Installation

Direct replacement in the battery compartment, without tools

Use

Continuous infusion and perfusion in hospitals, clinics, ICU, oncology, anaesthesia, emergency departments and intra-hospital transport

Recycling

RAEE/WEEE

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Ni-MH battery 9.6V 2.4Ah for Carefusion / BD Alaris Asena Gateway syringe pump | Replaces 1000SP00605 and 1000SP01795 | Ref. 88881138”

Your email address will not be published. Required fields are marked *