Description
1. The reliable power source for your Asena GP pump
This rechargeable 9.6 V, 2.1 Ah battery (code 88890298) is the spare part recommended for the infusion and perfusion pumps of the Carefusion / BD Alaris Asena GP and GP+ family, equipment widely used in hospital wards, intensive care units, oncology, anaesthesia and emergency departments. It is a nickel-metal hydride (Ni-MH) accumulator, cadmium-free and with a very low memory effect, which restores the equipment to full battery operation, both for continuous treatments and for patient transfers without mains connection. It is the practical solution for maintenance services, biomedical engineering and hospital purchasing departments that need a proven and traceable spare part, with the original equipment reference 1000SP01794.
2. Technical explanation: how this battery works
The Carefusion Alaris Asena GP pump administers drugs and fluids at a controlled flow rate over prolonged periods. To ensure continuity of infusion when the equipment is not connected to the mains, it incorporates an internal rechargeable battery that recharges automatically while the pump remains plugged in. This Ni-MH accumulator of 9.6 V / 2.1 Ah (≈20.2 Wh) delivers the nominal voltage and capacity required by the equipment and is managed by the pump’s own charging circuit: when battery life is noticeably reduced or the equipment warns of low battery prematurely, it is time to replace the pack. Installation is simple: it is inserted into the internal compartment of the pump without the need for adjustments or special tools, and recharging is carried out in the equipment itself when connected to the mains.
3. Technical Specifications
| Characteristic | Specification |
| Reference Cahnos (SKU) | 88890298 |
| Original equipment reference | 1000SP01794 (Carefusion / Alaris; previous designations 1000SP00487 and 1000SP01302) |
| Accumulator type | Ni-MH (nickel-metal hydride), rechargeable |
| Nominal voltage | 9.6 V |
| Nominal capacity | 2.1 Ah (2,100 mAh) |
| Approximate energy | ≈ 20.2 Wh |
| Compatibility | Carefusion / BD Alaris Asena GP and GP+ infusion and perfusion pumps; documented use in Gateway stations (verify batch and connector) |
| Approximate weight | ≈ 0.39 kg (according to technical data sheet from specialised distribution) |
| Recharge | Automatic, with the pump connected to the mains |
| Installation | Direct replacement in the pump’s battery compartment, without tools |
| Use | Continuous infusion and perfusion in hospitals, clinics, ICU, emergency departments and intrahospital transport |
| Presentation | 1 unit |
| Recycling | Manage in accordance with WEEE regulations |
4. Equivalences and Cross-References
Code 88890298 is the reference under which specialised distributors in the sector (e.g., VLAD, original battery range) catalogue this same 9.6 V / 2.1 Ah Ni-MH battery for the Asena GP pump, and it is consistently linked to the original equipment reference 1000SP01794 (with the earlier designations 1000SP00487 and 1000SP01302) in multiple independent sources. There is no registration in GUDID/EUDAMED for this spare part; treat these codes as catalogue data and original equipment reference. The references from other brands listed below belong to the same product category (9.6 V Ni-MH medical battery for the Asena GP / Gateway pump) and are classified as comparable by category, not 1:1 interchangeable; they require verification of capacity, dimensions and connector against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Medical Ni-MH battery for Alaris Medicalsystems Asena Syringe Pump GP / Gateway Workstation | CS-AMS324MD | Comparable by category (not interchangeable 1:1) | Ni-MH 9.6 V / 2,500 mAh (24 Wh), ≈75 × 54 × 33 mm; replaces 1000SP00487, 1000SP00605, 1000SP01302, ACMB1079, BATT/110324 and MB1079. Higher capacity (2.5 vs 2.1 Ah) and different pack dimensions; verify connector and compartment according to batch. Confirmed in the battery manufacturer’s datasheet and authorised distribution. |
| AKKUmed | Ni-MH battery for Alaris Medical System (Carefusion) Asena GP | 110324 | Comparable by category (not interchangeable 1:1) | Ni-MH 9.6 V / 2.7 Ah, ≈75 × 54 × 35 mm and ≈0.33 kg; original type 1000SP01794 (formerly 1000SP00487 and 1000SP01302). Same electrical performance in voltage but higher capacity and different brand assembly; verify connector and compartment dimensions. Confirmed in specialised distribution datasheets (AKKUmed / akkushop). |
| Axcom | Ni-MH battery for Carefusion Alaris Asena infusion pump GP | MB1079 | Comparable by category (not interchangeable 1:1) | Ni-MH 9.6 V / 2.7 Ah; OEM number type 1000SP01794 (formerly 1000SP00487 and 1000SP01302). Capacity higher than the original (2.7 vs 2.1 Ah); verified in the distributor’s datasheet (axcom-shop) with a 12-month warranty; check connector and compartment before replacing. |
There is no equivalence table validated by the equipment manufacturer (Carefusion / BD) for this reference; consult the technical department before use in tenders. Before a replacement, the following must be verified one by one: voltage (9.6 V), chemistry (Ni-MH), capacity, pack dimensions and connector against the specific equipment (Asena GP / GP+ / Gateway).
5. Selection tips and variants of interest
Confirm the exact pump model: this 9.6 V / 2.1 Ah battery is the one recommended for the Asena GP / GP+ family. Do not use it in the Asena GS-GH syringe pumps, which use a different 7.2 V / 2.7 Ah battery (Ref. 88888021), nor in the Asena GW volumetric pump (7.2 V / 1.7 Ah, Ref. 88888022), even though the connector may look similar.
Respect the voltage and chemistry: do not use batteries of a different voltage (7.2 V, 12 V) or a different chemistry (Li-ion, Ni-Cd) in this pump without prior technical validation, even if they fit physically; the equipment’s charging circuit is calibrated for 9.6 V Ni-MH.
Replace upon signs of wear: clearly reduced battery life or low battery warnings within a few hours of charging indicate that the accumulator has reached the end of its service life. Remember to give a full charge after installation and avoid repeated deep discharges.
Always order by reference: quote code 88890298 or the original equipment reference (1000SP01794 / 1000SP00487 / 1000SP01302) to avoid confusion with other batteries in the Asena and Alaris families.
For mixed fleets: consult our catalogue of batteries for infusion and perfusion pumps; we have spare parts for the Carefusion Alaris Asena (GP, GS-GH, GW, Gateway), Signature, IVAC 598, B. Braun, Terumo, Fresenius and other families. For tenders or bids, contact our technical-commercial department to confirm compatibility with your batch of equipment and a formalised quotation.