We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable 8 V 3.2 Ah battery for Abbott LC4 / LifeCare 4200 and 5000 infusion pump | Ref. 88888003

40,00 €

Rechargeable 8 V 3.2 Ah battery (Ref. 88888003) for Abbott infusion pumps of the LC4 family, compatible with models LifeCare 4200 and 5000. Sealed lead-acid cell (VRLA), leak-proof, maintenance-free and with direct installation, ensuring continuity of infusion in ICU, hospitalisation wards and patient transfers during power cuts. Approximate dimensions 133.5 × 36.5 × 66.6 mm and 0.737 kg weight. High-reliability spare part for biomedical engineering services and hospital purchasing. Price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88888003

Description

1. Reliable power for your Abbott infusion pumps

The battery for Abbott pumps of the LC4 family (Ref. 88888003) is the power replacement indicated to keep the Abbott LifeCare 4200 and 5000 infusion pumps operational. It is a sealed lead-acid (VRLA) rechargeable cell, leak-proof and maintenance-free, which ensures the equipment’s power supply when it is not connected to the mains, during patient transfers or in the event of a power interruption in the unit. An essential spare part for maintenance services, biomedical engineering and hospital purchasing departments that need standardised, traceable and economical replacements.

2. How this battery works in your infusion pump

The LifeCare series pumps use a sealed, rechargeable lead-acid cell as an internal energy backup. The cell supplies a nominal voltage of 8 V with a capacity of 3.2 Ah, sufficient to power the control electronics, the drive motor and the pump interface during operation without mains power. Its sealed (VRLA) construction allows spill-free mounting and installation takes just a few minutes, reusing the original equipment connector. While the pump remains connected to the mains, the battery recharges automatically and is ready for the next use; when it begins to discharge, the equipment alerts the user, which is the recommended time to connect the pump to the mains or replace the cell. Like any sealed lead battery, it offers a long service life if kept charged and not subjected to repeated deep discharges.

3. Technical Specifications

Data verified against the authorised distributor’s technical data sheet (document 88888003, Battery 8V 3.2Ah for pump LifeCare 4200 Abbott, available on the RS Components network) and against the cross-reference of the same code in the VLAD catalogue (France).

Characteristic Value
Reference (SKU) 88888003
Model per distribution data sheet EXA3.2-8
Battery type Sealed rechargeable lead-acid (VRLA), leak-proof
Nominal voltage 8 V
Nominal capacity 3.2 Ah
Technology Lead (VRLA), maintenance-free
Dimensions (L × W × H) 133.5 × 36.5 × 66.6 mm (134 × 37 × 67 mm per data sheet)
Approximate weight 0.737 kg
Compatibility Abbott LifeCare 4200 and 5000 infusion pumps (LC4 family from the Cahnos catalogue)
Rechargeable Yes
Application Continuous infusion and PCA in ICU, hospitalisation wards and transfers
Presentation Unit

4. Equivalences and Cross-References

Ref. 88888003 corresponds to the standard sealed lead-acid cell format of 8 V / 3.2 Ah used in the energy backups of the Life Care family infusion pumps. The references from other manufacturers listed below belong to this same product category, have been verified against official data sheets or specialised distribution and are classified as comparable by category, not 1:1 interchangeable: before replacement, the connector type (2 or 4 pins), dimensions and polarity must be checked against the specific pump compartment.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Power-Sonic PS series (General Purpose SLA, AGM) PS-832 (F1 terminals) Comparable by category (not interchangeable 1:1) SLA/VRLA cell of 8 V / 3.2 Ah in AGM with Faston F1 terminals and dimensions 134 × 36.5 × 63-69 mm; confirmed in the manufacturer’s official data sheet. It is the cell format used in the connector packs of the Life Care 5000 / PCA pumps; check the equipment connector.
BBM Battery / R&D Batteries Medical battery for Abbott Life Care 5000 Plum 5875 / 5875-P Comparable by category (not interchangeable 1:1) SLA/VRLA pack of 8 V / 3.2 Ah with 4-pin connector documented as a replacement for the Life Care 5000 Plum, Plum XL, Plum XLM and PCA III models (Hospira/Ross); manufacturer with Health Canada licence. Not documented for LifeCare 4200; check connector (2 or 4 pins).
ICU Medical / Hospira LifeCare PCA 3 battery 830-03650-905 Comparable by category (not interchangeable 1:1) Rechargeable VRLA battery of 8 V with Sonnenschein cell for the LifeCare PCA 3 pump; reference listed in specialised biomedical spare parts distribution. Check connector and compartment dimensions.
AKKUmed / WISE Battery Abbott LifeCare 4200 / 5000 lead-acid battery Commercial reference AKKUmed (CE) Comparable by category (not interchangeable 1:1) Lead-acid cell of 8 V / 3.2 Ah CE-compliant, with approximate dimensions of 133.5 × 36.5 × 66.6 mm and 0.78 kg; documented specifically for LifeCare 4200 and 5000. Check the connector of the specific unit.

There is no equivalence table validated by the manufacturer (Abbott) that authorises third-party batteries; consult the technical department before use in tenders. Before replacement, the following must be checked one by one: voltage (8 V), capacity (3.2 Ah), chemistry (sealed lead-acid), connector type (2 or 4 pins depending on the pump model) and compartment dimensions (format approx. 133.5 × 36.5 × 66.6 mm).

5. Selection tips and variants of interest

Identify the exact model of your pump: this 8 V / 3.2 Ah battery is documented for the Abbott LifeCare 4200 and 5000 family (called LC4 in the Cahnos catalogue). Confirm the connector type (2 or 4 pins) and polarity orientation before mounting; do not replace it with cells of a different voltage or with integrated wiring without prior technical validation.

Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the pump is to remain off for long periods, keep it connected to the mains periodically to preserve the charge. Replace the battery when the autonomy is appreciably reduced or the equipment warns of low battery, and check the condition of the connector at each replacement.

For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility with your pump fleet, delivery times and a formalised quotation.

Additional information

Product type

Rechargeable sealed lead-acid battery (VRLA)

Distribution reference

88888003 (model EXA3.2-8 per distributor technical data sheet)

Nominal voltage

8 V

Capacity

3.2 Ah

Technology

Sealed lead-acid (VRLA), maintenance-free

Dimensions

133.5 × 36.5 × 66.6 mm

Weight

0.737 kg

Compatibility

Abbott LifeCare 4200 and 5000 infusion pumps (LC4 family)

Rechargeable

Yes

Application

Infusion pumps in ICU, hospitalisation and patient transfers

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable 8 V 3.2 Ah battery for Abbott LC4 / LifeCare 4200 and 5000 infusion pump | Ref. 88888003”

Your email address will not be published. Required fields are marked *