Description
1. Reliable power for your operating table
The EXAG12-12 battery is the recommended power replacement for surgical tables and supporting medical accessories that work with 12 V sealed lead-acid cells. Its gel (VRLA) chemistry guarantees stable, leak-proof supply, with the autonomy needed to keep the table operational during a power cut and complete patient positioning safely. It is a rechargeable, maintenance-free replacement that is easy to install, restoring full operability to the equipment in minutes. Ref. Cahnos 33192139; price per unit.
2. How this battery works
The EXAG12-12 uses valve-regulated lead-acid (VRLA) chemistry with electrolyte immobilised in gel, making it sealed, rechargeable and suitable for frequently used medical equipment. It supplies a nominal voltage of 12 V with a capacity of 12 Ah (20-hour rate), sufficient to power the control electronics, actuators and positioning systems of the table during clinical activity, as well as other auxiliary medical devices. Its sealed construction allows spill-proof installation, with over 99 % internal gas recombination and low-pressure safety valves, and its format corresponds to the standard market cell 12 V / 12 Ah, compatible with the usual battery compartment of these tables, reusing the original wiring. Like all VRLA cells, it offers a typical design life of 3 to 5 years under nominal use and charge conditions, with excellent recovery after moderate discharges.
3. Technical Specifications
| Characteristic | Specification |
| Reference Cahnos (SKU) | 33192139 |
| Model / brand | EXAG12-12 (Exalium) |
| Battery type | Sealed lead-acid (SLA / VRLA) |
| Technology | Gel, immobilised electrolyte |
| Nominal voltage | 12 V |
| Nominal capacity | 12 Ah (20-hour rate) |
| Terminals | Family Faston format (verify F1/F2 and orientation according to equipment) |
| Standard market cell format | 12 V / 12 Ah (NP12-12 format base; typical dimensions 151 × 98 × 97.5 mm, to be verified against the supplied batch) |
| Rechargeable | Yes; it recharges with the equipment charger |
| Maintenance | Maintenance-free |
| Construction | Sealed, leak-proof; over 99 % internal gas recombination |
| Application | Surgical tables, hospital accessories and auxiliary medical devices |
| Presentation | Unit |
Note: the cell format indicated is the market standard to which this reference belongs and must be verified against the compartment of the specific table (height dimension, terminal type and polarity orientation).
4. Equivalences and Cross-References
The EXAG12-12 corresponds to the standard sealed lead-acid cell format 12 V / 12 Ah (reference cell format Yuasa NP12-12). The references from other manufacturers listed below belong to this same product category (VRLA battery 12 V and 12 Ah, including gel technology), have been cross-checked against official manufacturer datasheets and are classified as comparable by category, not 1:1 interchangeable: before replacement, the terminal type, dimensions, chemistry and polarity must be verified against the compartment of the specific table.
| Manufacturer / Brand | Family / Model | Code / reference | Equivalence level | Technical differences / Remarks |
| Exide / Sonnenschein | A500 dryfit series (gel) | A512/10 S | Comparable by category (not interchangeable 1:1) | 12 V / 10 Ah in gel technology, 152 × 98 × 98.4 mm, Faston terminal 4.8 mm, ≈4.0 kg, VdS approval. Confirmed in official manufacturer datasheet; capacity 2 Ah lower, verify autonomy requirements. |
| GS Yuasa | NP series (VRLA) | NP12-12 / NP12-12-250FR | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah, Faston F2 terminals (6.35 mm / 0.250″), 151 × 98 × 97.5 mm, ≈4.0 kg (4.05 kg according to official datasheet). Confirmed in official manufacturer datasheet; AGM chemistry vs gel, verify height dimension and terminal type. |
| Power-Sonic | PS series (AGM, general purpose) | PS-12120 (F2) | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah AGM with F2 terminals and dimensions 151 × 98 × 95 mm, ≈3.24 kg. Confirmed in official manufacturer datasheet; slightly lower height and AGM chemistry vs gel, verify compartment. |
| CSB Battery | GP series (AGM) | GP12120 | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah AGM, 151 × 97 × 94 mm, ≈3.67 kg, up to 5 years in standby service. Confirmed in official CSB datasheet; verify height dimension and F2 terminal of the batch. |
| Panasonic | LC-RA Series (AGM) | LC-RA1212P / LC-RA1212PG1 | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah, 151 × 94 × 98 mm, Faston terminals (0.187″/4.75 mm according to authorised distribution), ≈3.8 kg. Confirmed in manufacturer datasheet and authorised distribution; verify dimension and AGM chemistry vs gel. |
| Exide | Powerfit S300 Series (AGM) | S312/12 SR | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah AGM with VdS approval, 152 × 98 × 102 mm, Faston terminal 6.3 mm, ≈3.8 kg. Confirmed in official manufacturer datasheet; height 4.5 mm higher and AGM chemistry vs gel, verify compartment. |
There is no equivalence table validated by the manufacturer that authorises third-party batteries; consult with the technical department before use in tenders. Before replacement, each must be verified one by one: voltage (12 V), capacity (12 Ah), chemistry (sealed lead-acid gel or AGM), terminal type (Faston F1/F2 according to equipment) and compartment dimensions (standard cell format 12 V 12 Ah).
5. Selection tips and variants of interest
Identify the exact table model: this 12 V / 12 Ah gel battery covers medium-support equipment and auxiliary devices; always confirm the compartment, terminal type (Faston) and polarity orientation before fitting. Do not replace it with cells of another voltage or with integrated wiring without prior technical validation.
Prevention and maintenance: VRLA cells self-discharge slowly when idle; if the table will remain off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5 V). Replace the battery when the autonomy reduces appreciably or the equipment gives a low battery warning.
Variants in the same family on Cahnos: EXA7-12 12 V / 7 Ah AGM battery (ref. 33192173), EXAG7-12 12 V / 7 Ah gel battery (ref. 88889675), EXA12-12 12 V / 12 Ah battery (ref. 88889537), EXAG17-12 12 V / 17 Ah battery (ref. 88889674) and EXA18-12 12 V / 18 Ah battery (ref. 88889541). Do not interchange these references between models: each table accepts a specific voltage and capacity.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formal quotation.





Reviews
There are no reviews yet.