Description
Replacement battery for patient ventilation, no surprises
This 12V, 5Ah battery is the designated power replacement for the Air Liquide Galileo family of breathing and ventilation systems, mechanical ventilation equipment found in intensive care units, intra-hospital transport and home care. It is a sealed valve-regulated lead-acid (VRLA) cell with absorbed glass mat (AGM) electrolyte, ensuring a stable, leak-proof and maintenance-free power supply, with the autonomy required to keep the ventilator operational during mains power outages or patient transfers. A technically proven replacement, ready to install using the equipment’s original wiring harness.
How this battery works in your ventilation equipment
The cell uses valve-regulated lead-acid (VRLA) chemistry with AGM technology, making it sealed, rechargeable and suitable for use in portable medical devices. It delivers a nominal voltage of 12V with a capacity of 5Ah at a 20-hour rate, sufficient to power the Galileo’s ventilator motor, display and control electronics during extended periods of operation without mains power. Its sealed construction allows spill-proof mounting, and its Faston F1 terminals (0.187 inches / 4.75 mm) fit into the equipment’s battery compartment using the original wiring. Each Galileo ventilator incorporates two batteries of this format, so it is recommended that both units be replaced at the same time. The typical design life is 3 to 5 years under nominal conditions of use and charging.
Technical specifications
| Characteristic | Specification |
|---|---|
| Reference Cahnos (SKU) | 88889682 |
| Related internal reference | 88888297 (documented in internal catalogue) |
| Battery type | Sealed lead-acid (VRLA / AGM), maintenance-free |
| Nominal voltage | 12V |
| Capacity | 5Ah (20-hour rate) |
| Chemistry | Valve-regulated lead-acid, absorbed electrolyte (AGM) |
| Terminals | Faston F1 (0.187 inches / 4.75 mm) |
| Dimensions (L × W × H) | 90 x 70 x 102 mm (NP5-12 cell format) |
| Approximate weight | 1.7 kg |
| Rechargeable | Yes |
| Units per device | 2 batteries per ventilator |
| Compatible equipment | Air Liquide / TAEMA Galileo (Hamilton Medical Galileo) breathing and ventilation systems |
| Use | Power supply for medical ventilators in ICU, transport and home care |
| Estimated life | 3-5 years under nominal conditions (typical VRLA) |
| Presentation | Unit |
Equivalences and cross-references
The cell powering the Galileo ventilator conforms to the standard sealed lead-acid 12V / 5Ah format with Faston F1 terminals, equivalent to the generic Yuasa NP5-12 reference cell. The references from other brands listed below belong to the same product category (12V, 5Ah VRLA/SLA battery with F1 terminal) and have been cross-referenced against manufacturer data sheets, official specifications and specialist distribution cross-reference tables; they are classified as comparable by category, not 1:1 interchangeable, and require verification of terminal, dimensions and polarity before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GS Yuasa (Yuasa) | NP series (VRLA/AGM cell) | NP5-12 / NP5-12FR | Comparable by category (not interchangeable 1:1) | Sealed lead-acid cell 12V / 5Ah with Faston F1 terminals (0.187 in), dimensions 90 x 70 x 105.5 mm. Confirmed in the official manufacturer’s data sheet (FR variant with flame-retardant casing). This is the reference cell format; verify F1 terminal on the batch. |
| Power-Sonic | PS series (General Purpose SLA) | PS-1250 F1 | Comparable by category (not interchangeable 1:1) | 12V / 5Ah with F1 terminal and AGM technology, confirmed in the manufacturer’s official data sheet and specialist distribution as a replacement for the Galileo ventilator. Slightly lower cell height (~101 mm); verify compartment. |
| Raion Power | RG series (medical battery) | RG1250T1 | Comparable by category (not interchangeable 1:1) | 12V / 5Ah with T1 terminals (Faston 0.187 in), documented as compatible with the Hamilton Medical Galileo ventilator in the manufacturer’s data sheet and authorised distribution. Verify batch dimensions. |
| OSI Batteries (Unipower) | Biomedical battery | B00334 (SKU NP5-12A-100011) | Comparable by category (not interchangeable 1:1) | Sealed lead-acid battery 12V / 5Ah for Hamilton Medical Galileo, confirmed in the official OSI Batteries data sheet with Faston 0.187 in terminals and dimensions 89.9 x 69.9 x 105.9 mm. |
| BBM Battery | Certified medical battery | 5388 | Comparable by category (not interchangeable 1:1) | SLA/VRLA 12V / 5Ah battery certified by Health Canada for medical use, documented as a replacement for the Hamilton Galileo (369089) and cross-referenced to B00334. Verify terminal and dimensions. |
| Alpha Source | Biomedical replacement | AS00331 / AS00319 | Comparable by category (not interchangeable 1:1) | Cross-referenced listings for the Hamilton Galileo Ventilator (369089) in specialist distribution tables. Confirm terminal version ordered. |
| Luminous / specialist distribution | 12V 5Ah battery (cross-referenced) | LIF00922-2 | Comparable by category (not interchangeable 1:1) | Code listed in distribution cross-reference tables for the Galileo ventilator; verify F1 terminal and dimensions before replacement. |
There is no equivalence table validated by the equipment manufacturer authorising third-party batteries; consult the technical department before use in tenders. Before replacement, the following must be verified one by one: voltage (12V), capacity (5Ah), chemistry (sealed lead-acid VRLA/AGM), terminal type (Faston F1, 0.187 inches), compartment dimensions (NP5-12 format: approx. 90 x 70 x 102 mm) and number of units required (2 per device).
Selection tips and variants of interest
- Identify the exact model of your equipment: this 12V / 5Ah battery is the one indicated for the Air Liquide Galileo ventilator family and its Hamilton Medical Galileo equivalent. Confirm the number of batteries your unit holds (2 per equipment in the documented configuration) before placing the order.
- Check the terminal: the equipment requires Faston F1 terminals (0.187 inches / 4.75 mm). Do not replace with cells with terminals of another size (F2) or with integrated wiring without prior validation.
- Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the equipment is to remain off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5V). Replace the battery when the runtime is reduced or the equipment warns of low battery.
- For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formalised quotation.





Reviews