12V 2.3Ah VRLA Lead-Acid Battery for Electrocardiograph Schiller/Odam CardioVit AT2 · AT101 · AT102 | NP2.1-12 Format · Ref. 88889703

16,00 €

12V 2.3Ah VRLA battery of sealed lead-acid (AGM) for electrocardiographs Schiller/Odam CardioVit AT2, AT101 and AT102, in NP2.1-12 cell format with Faston F1 (0.187″) terminals. Rechargeable replacement, maintenance-free and with direct installation, which restores reliable autonomy to the equipment for successive electrocardiographic recordings. Reference Cahnos 88889703 (manufacturer reference Y2112); the 2.1Ah variant of the same family is supplied under reference 88888533. Ideal for hospitals, clinics and emergency departments.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88889703

Description

1. The reliable power source for your CardioVit

This 12 V, 2.3 Ah battery is the recommended replacement power source for Schiller/Odam electrocardiographs of the CardioVit AT2, AT101 and AT102 series, equipment widely used in cardiology clinics, emergency departments and primary care. Its sealed lead-acid (VRLA) technology guarantees a stable, leak-proof power supply with enough autonomy to complete successive examinations without relying on the mains. It is a high-performance, rechargeable, maintenance-free replacement that restores full operability to the equipment in just a few minutes.

2. Technical explanation: how this battery works

The battery uses valve-regulated lead-acid (VRLA) chemistry with absorbed glass mat (AGM) electrolyte, making it sealed, rechargeable and suitable for portable medical devices. It supplies a nominal voltage of 12 V with a capacity of 2.3 Ah (20-hour rate), sufficient to power the electrocardiograph recording, thermal printing and display during clinical activity. Its sealed construction allows spill-proof installation and its compact standard cell format NP2.1-12 fits into the CardioVit battery compartment. The terminals are of the Faston F1 (0.187 inches / 4.75 mm) type, the same as those used by the generic Yuasa NP series reference cell. Like all VRLA cells, it offers a typical design life of 3 to 5 years under nominal use and charge conditions, with good recovery after deep discharges. Replacement is carried out by opening the rear housing of the unit, removing the exhausted cell and connecting the new one observing polarity.

3. Technical Specifications

Characteristic Specification
Battery type Sealed lead-acid (VRLA / AGM), maintenance-free
Nominal voltage 12 V
Capacity 2.3 Ah (20-hour rate; NP2.1-12 cell format)
Chemistry Valve-regulated lead-acid, absorbed electrolyte (AGM)
Terminals Faston F1 (0.187 inches / 4.75 mm)
Format / dimensions Standard cell NP2.1-12 / NP2.3-12 (approx. 178 × 34 × 60 mm; verify compartment)
Weight Approx. 0.85 kg
Manufacturer reference Y2112 (Exalium distribution technical data sheet; generic Yuasa NP2.1-12 cell)
Reference Cahnos 88889703
Rechargeable Yes
Compatible equipment Electrocardiograph Schiller/Odam CardioVit AT2, AT101, AT102
Common market use Also documented in CardioVit AT6, AT60, AT-2 Plus, PT60 and Argus LCM (verify compartment before replacement)
Professional use Power supply for diagnostic equipment (ECG) in hospitals, clinics and diagnostic centres
Installation Direct fit in the battery compartment, no adaptations required

4. Equivalences and Cross-References

The cell powering the CardioVit AT2 family conforms to the standard 12 V sealed lead-acid format with Faston F1 terminals, related to the generic Yuasa NP series reference cell (NP2.1-12 / NP2.3-12). Note on codes: the Cahnos SKU 88889703 corresponds to the assembled cell reference Y2112 (NP2.1-12 format); the generic cell codes (NP2.1-12, NP2.3-12) belong to the cell manufacturer and must not be confused with Schiller AG part numbers. The references from other brands listed belong to the same product category (12 V SLA battery with F1 terminal for Schiller electrocardiograph) and are classified as comparable by category, not 1:1 interchangeable; they require verification of terminal, dimensions and polarity against the specific equipment before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GS Yuasa (Yuasa) NP series (VRLA cell) NP2.1-12 / NP2.3-12FR Comparable by category (not interchangeable 1:1) 12 V sealed lead-acid cell with Faston F1 terminals; NP2.1-12 confirmed in the manufacturer’s official datasheet (178 × 34 × 60 mm) and NP2.3-12FR listed for the Schiller AT-2 / AT-2 Plus / AT102 family in specialised distribution. Check capacity and F1 terminal of the batch.
Power-Sonic PS series (SLA) PS-1221 Comparable by category (not interchangeable 1:1) 12 V / 2.1 Ah VRLA/AGM battery with Faston F1 terminals, 178 × 60 × 35 mm, confirmed in the manufacturer’s official datasheet as equivalent to the NP2.1-12 cell. Lower capacity (2.1 Ah) compared to the 2.3 Ah of this reference.
OSI Batteries Biomedical battery for Schiller AT-2 / AT-2 Plus B00317 Comparable by category (not interchangeable 1:1) 12 V / 2.3 Ah sealed lead-acid battery, Faston 0.187 inch terminals and dimensions 178 × 34 × 64 mm, confirmed in the manufacturer/distributor datasheet for the Schiller AT-2 / AT-2 Plus family. Same specifications; check terminal and polarity.
Alpha Source OEM replacement for Schiller ECG AS00221 / AS00317 Comparable by category (not interchangeable 1:1) Cross references listed for Schiller America AT-2 / AT-2 Plus / AT102 / PT60 electrocardiographs (12 V SLA, F1 terminal) in specialised distribution tables. Confirm terminal version of the order.
Interstate Batteries SLA 12 V range SLA1015 Comparable by category (not interchangeable 1:1) 12 V SLA battery included in the compatibility tables for the Schiller AT-2 / AT102 family. Check dimensions and terminals before replacement.
MK Battery Biomedical range BMED00317 Comparable by category (not interchangeable 1:1) Documented cross reference for Schiller AT-2 / AT102 electrocardiograph (12 V / 2.3 Ah SLA). Verify presentation and terminals of the batch.

There is no equivalence table validated by the equipment manufacturer that authorises third-party batteries; consult with the technical department before use in tenders. Before replacement, each point must be verified individually: voltage (12 V), capacity (2.1-2.3 Ah depending on variant), chemistry (sealed lead-acid VRLA), terminal type (Faston F1, 0.187 inch) and compartment dimensions (NP2.1-12 format, approx. 178 × 34 × 60 mm).

5. Selection tips and variants of interest

  • Identify the exact model of your equipment: this 12 V / 2.3 Ah battery in NP2.1-12 format is the recommended replacement for CardioVit AT2, AT101 and AT102. If your equipment is an AT6, AT60, AT-2 Plus or PT60, confirm the compartment with the technical department, as they share the cell format in a large part of the installed base but this should not be assumed without verification.
  • Check the terminal: the equipment requires Faston F1 terminals (0.187 inch). Do not replace with cells with terminals of another size or with integrated wiring without prior validation.
  • Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the equipment is to remain off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (approximately 10.5 V). Replace the battery when recording autonomy decreases appreciably or the equipment indicates low battery.
  • Variants of the same family at Cahnos: there is a 12 V / 2.1 Ah variant for the same CardioVit AT2-AT101-AT102 family under reference 88888533; for the CardioVit AT102+ (7.4 V / 4.2 Ah battery) reference 88881115 is supplied, and for the AT10+ (21.6 V / 2.3 Ah) reference 88888209. Do not interchange these references between models: each unit accepts a specific voltage, capacity and terminal format.
  • Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and formalised quotation.

Additional information

Nominal voltage

12 V

Capacity

2.3 Ah (20-hour rate; NP2.1-12 cell format)

Chemistry

Valve-regulated lead-acid, absorbed electrolyte (AGM)

Terminals

Faston F1 (0.187 inches / 4.75 mm)

Format dimensions

Standard cell NP2.1-12 / NP2.3-12 (approx. 178 × 34 × 60 mm)

Weight

Approx. 0.85 kg

Manufacturer reference

Y2112 (distribution technical data sheet; generic Yuasa NP2.1-12 cell)

Rechargeable

Yes

Compatibility

Schiller/Odam CardioVit AT2, AT101, AT102 (also commonly used in AT6, AT60, AT-2 Plus, PT60 and Argus LCM; verify)

Use

Power supply for electrocardiographs in hospitals, clinics and diagnostic centres

Installation

Direct fit in the battery compartment, no adaptations required

Battery type

Sealed lead-acid (VRLA / AGM), maintenance-free

Dimensions

Approx. 178 × 34 × 60 mm (NP2.1-12 format; verify compartment)

Compatible equipment

Schiller/Odam CardioVit AT2, AT101, AT102 (also documented in AT6, AT60, AT-2 Plus, PT60 and Argus LCM; verify compartment)

Estimated life

3-5 years under nominal conditions (typical VRLA)