Description
1. Replacement battery for your Novacor Dyasys Holter
Keep your Novacor Dyasys MFR Ambulatory Blood Pressure Holter always operational with this rechargeable battery of 3.6V and 0.86Ah, designed as a specific replacement for reference ACC-0750-00. It is the ideal component for cardiology departments, ambulatory diagnostic units, hospitals and clinics that need to ensure the continuity of their blood pressure recordings without interruptions.
A battery in good condition is key for the device to complete the programmed measurement cycles, avoid data loss due to voltage drops, and maintain the diagnostic reliability required by an ambulatory blood pressure monitoring (ABPM) device.
2. What is the Ambulatory Blood Pressure Holter and why the battery is critical
The Ambulatory Blood Pressure Holter (or ambulatory blood pressure monitor, ABPM) is a medical device that records the patient’s blood pressure automatically and periodically for 24 hours or more, while the patient goes about their normal daily life. These devices perform programmed measurements with cuff inflation, which requires a constant power supply throughout the recording.
The Ni-MH (nickel-metal hydride) 3.6V battery is the power solution for this type of Holter: it offers a stable nominal voltage, tolerates frequent recharge cycles, and maintains the device’s portability by not requiring a mains connection. A battery replacement in poor condition or with reduced capacity can cause incomplete recordings, low battery alarms, or loss of clinical data, so it is recommended to replace it preventively according to the device’s maintenance schedule.
3. Technical Specifications
The main features of this replacement battery are detailed below.
| Field | Detail |
| Product | Replacement rechargeable battery |
| Application | Novacor Dyasys MFR Ambulatory Blood Pressure Holter (ACC-0750-00) |
| Family | Batteries for ECG and Holter |
| Equipment manufacturer reference | ACC-0750-00 |
Technical features:
| Parameter | Specification |
| Technology / chemistry | Ni-MH (nickel-metal hydride) |
| Nominal voltage | 3.6 V |
| Nominal capacity | 0.86 Ah (860 mAh) |
| Cell type | Prismatic (format 12670) |
| Configuration | 3 cells in series |
| Approximate dimensions | 48 × 20 × 17 mm (depending on market assembly) |
| Approximate weight | ≈ 54 g |
| Rechargeable | Yes |
| Intended use | Ambulatory blood pressure recording (ABPM) and ECG on Novacor Dyasys / Diasys Integra devices |
| Presentation | 1 unit |
Note: the dimensions and weight indicated are approximate and come from equivalent market assemblies; for fit validation, it is recommended to compare with the actual device compartment or consult the technical department.
4. Equivalences and Cross-References
This battery is marketed under the equipment reference ACC-0750-00, used by Novacor for the Dyasys Ambulatory Blood Pressure Holter (also referred to as Diasys / Diasys Integra in different markets). Various medical spare parts specialists use their own warehouse codes for the same functional purpose; the following market reference matches this replacement in technology, voltage and capacity:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| CardioDépôt (replacement assembly for ABPM) | Battery for Novacor Diasys Integra | MGH0081 | Not verified | Same Ni-MH 3.6 V chemistry; published capacity 0.8 Ah; compatible dimensions (18 × 48 × 17 mm). Market reference used for the same Novacor Diasys/Dyasys Integra Holter; pending confirmation against official source from the equipment manufacturer. |
Likewise, European battery assemblers (AccuCell / AKKUmed, Eurosep, among others) offer assemblies under type ACC-0750-00 with 3.6 V and 0.8-0.86 Ah, confirming the existence of a homogeneous replacement market for this application. The reference does not appear as an independently registered product in the GUDID/EUDAMED regulatory databases as it is a replacement accessory integrated into the device.
There is no equivalence table validated by the equipment manufacturer (Novacor) for this reference; consult with the technical department before using in a tender.
5. Selection tips and variants of interest
- Verify the equipment reference: confirm that your device is the Novacor Dyasys MFR / Diasys Integra Ambulatory Blood Pressure Holter (ref. ACC-0750-00) before replacing the battery.
- Always keep a charged spare battery: in cardiology departments with several Holters in rotation, have a backup battery per device to avoid interrupting 24-hour recordings.
- Ni-MH battery maintenance: avoid repeated deep discharges and store it with a partial charge if not used for extended periods; this will extend its service life.
- Check the condition of the connector and compartment: when installing the new battery, ensure the contacts seat properly and the compartment lid closes correctly.
- Top up your consumables stock: also review spare cuffs and armbands for the Holter to keep the device ready for each patient.
If you need to confirm the exact fit of this battery in your unit or manage an order for several devices, our technical-commercial team can advise you.