Nihon Kohden Cardiofax 8023G X041A 12V 2.3Ah lead-acid battery for electrocardiograph | Ref. 88888423

28,80 €

Sealed lead-acid battery 12V 2.3Ah for Nihon Kohden Cardiofax 8023G electrocardiograph (factory reference X041A). High-reliability replacement that guarantees continuous power supply in demanding clinical environments: uninterrupted recordings, reliable start-up and direct replacement without adapters. Compatible with Cardiofax family models (8420K, 8830K, 90xx, 91xx, 9022, TEC71xx/TEC72xxx).

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888423

Description

Nihon Kohden Cardiofax 8023G Battery (X041A) – 12V 2.3Ah

Keep your electrocardiograph always operational with this 12V 2.3Ah replacement battery for the Nihon Kohden Cardiofax family. It is a sealed lead-acid (VRLA) rechargeable battery designed to provide stable power during prolonged ECG recording sessions, even when moving within the hospital or in primary care. It is the direct replacement solution for the 8023G model and its factory reference X041A, which will prevent equipment downtime due to exhaustion of the original battery.

Technical explanation

The Nihon Kohden Cardiofax 8023G electrocardiograph is a 1-channel electrocardiographic recording device that, in its portable configuration, is powered by an internal sealed lead-acid rechargeable battery. This chemistry delivers a nominal voltage of 12V with a capacity of 2.3Ah (approximately 23Wh of useful energy), sufficient to complete ECG recordings in the consulting room and during transfers without depending on the mains supply. Being a sealed VRLA battery, it requires no electrolyte maintenance, supports cyclic recharging with the device’s own integrated charger, and must be replaced when loss of autonomy or a low battery warning is detected on the screen. Replacement is direct: same voltage, same capacity and same connector as the original Nihon Kohden battery (X041A / LCT-1912ANK).

Technical specifications

Characteristic Detail
Reference Cahnos 88888423
Nihon Kohden factory reference X041A
Type / technology Rechargeable sealed lead-acid battery (VRLA)
Nominal voltage 12 V
Capacity 2.3 Ah (2300 mAh) – approx. 27.6 Wh
Approximate dimensions 182 x 61 x 23 mm (according to standard homologation)
Approximate weight 0.72 kg
Application Nihon Kohden Cardiofax electrocardiographs 8023G, 8420K, 8830K, 90xx, 91xx, 9022, TEC71xx / TEC72xxx
Mounting type Direct replacement, without adapters or special tools

Equivalences and cross-references

The original factory reference for this battery is X041A (Nihon Kohden), which is consistently associated with the OEM codes LCT-1912ANK, LCS-1912AK, LCT-1912NK and LC-SA122R3AU in compatibility listings from authorised distributors. There is no equivalence table validated by the manufacturer Nihon Kohden for this battery; the cross-references are provided for guidance only and must be confirmed with the technical department before use in tenders.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Nihon Kohden Cardiofax (original OEM codes) LCT-1912ANK / LCS-1912AK / LCT-1912NK / LC-SA122R3AU Exact reference equivalence (same manufacturer) Factory codes for the same 12V 2.3Ah lead battery for the Cardiofax family, consistently cited by authorised distributors.
Raion Power Medical battery RG1223A RG1223A Comparable by category (not interchangeable 1:1) Sealed lead 12V 2.3Ah, guaranteed equal to or better than OEM specification; different manufacturer (approved, not original Nihon Kohden). Source: Raion Group technical data sheet.
VLAD / Exalium Exalium approval (original ref. X041A) Exalium – origin X041A Comparable by category (not interchangeable 1:1) Lead 12V, 180 x 61.7 x 23 mm, 0.693 kg; suitable for Cardiofax 8023G, 8420K, 8830K, 90xx, 91xx, 9022, TEC71xx/TEC72xxx. Not original Nihon Kohden.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

Selection tips and variants of interest

Before replacing the battery in your Cardiofax, check three parameters on the label of the removed battery: voltage (12V), technology (sealed lead-acid) and factory reference (X041A). If your device is from the Cardiofax 8023G, 8420K, 8830K, 90xx, 91xx, 9022 or TEC71xx/TEC72xxx family, this reference is the correct one. At Cahnos we also have other Nihon Kohden batteries for electrocardiographs of the same family: the X041B 12V 2.9Ah for Cardiofax 4201-6000 (Ref. 88888425), the X071 12V 2Ah Ni-MH for Cardiofax 1250, 9620 and 9629 (Ref. 88888426) and the X073 12V 3.6Ah Ni-MH for models 1500-1550 (Ref. 88888765). For a complete maintenance plan, it is recommended to purchase one spare battery for each electrocardiograph in the unit and rotate them with the original battery.

Additional information

Technology

Sealed lead-acid (VRLA)

Nominal voltage

12 V

Capacity

2.3 Ah (2300 mAh)

Manufacturer reference

X041A (Nihon Kohden)

Dimensions

Approx. 180 x 23 x 62 mm (L x W x H)

Weight

Approx. 0.69 – 0.74 kg

Terminals

Faston 4.8 mm (F1)

Compatibility

Nihon Kohden Cardiofax 8023G, 8420K, 8830K, 90xx, 91xx, 9022, TEC71xx/TEC72xxx

Use

Hospitals, clinics, consulting rooms, primary care and medical transport

Recycling

RAEE/WEEE

Voltage

12 V

Energy

Approx. 27.6 Wh

Approximate dimensions

182 x 61 x 23 mm

Approximate weight

0.72 kg

OEM codes

LCT-1912ANK, LCS-1912AK, LCT-1912NK, LC-SA122R3AU

Product type

Rechargeable, genuine replacement

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Nihon Kohden Cardiofax 8023G X041A 12V 2.3Ah lead-acid battery for electrocardiograph | Ref. 88888423”

Your email address will not be published. Required fields are marked *